The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Circulating Markers of Abdominal Aortic Aneurysm Presence and Progression
Open accessAbstract
Over the last decade abdominal aortic aneurysm (AAA) has increasingly been recognised as an important cause of mortality in older persons. In 1999 for example AAA was noted to be the 15th leading cause of mortality in the USA [1]. Exact estimates of AAA-related fatalities are hampered by the low rate of post-mortems when sudden death occurs in elderly subjects, however, recent figures suggest that AAA accounts for approximately 15,000 deaths annually in the USA despite the increasing numbers of elective AAA repairs [2,3]. Approximately 25,000 endovascular and open AAA repairs are performed annually in the USA [3]. Ultrasound screening of men >65 years has been demonstrated to reduce AAA-related mortality and selective screening (of men aged ≥65 who have ever smoked) has been introduced in the USA [4]. Most screen-detected AAAs are of small size (<55mm) and surgery for these AAAs has not been demonstrated to improve outcome [5-7]. In an screening study of 12,203 men ≥65 years performed in Australia for example, 814 (6.7%) had a small AAA measuring 30-54mm but only 61 (0.5%) a large AAA (≥55mm) [8]. The increase in identification of small AAAs resulting from screening programs, in association with an ageing population, will highlight the number of deficiencies in current diagnosis and management of this condition. Firstly, there are no accurate non-imaging methods of diagnosing small AAAs, with clinical examination being inaccurate [9]. Secondly, prognostic determinants for AAA are relatively poorly defined [10]. Approximately 70% of 40-55mm AAAs expand within 10 years to a size requiring treatment [6,7]. There are however large intra and inter-patient variations in rates of expansion of small AAAs during follow-up [10]. To date only initial aortic diameter has been consistently shown to predict subsequent increase in aortic diameter [10-13]. Smoking has been associated with increased, and diabetes with decreased, AAA expansion in some, but not all studies [10-13]. More accurate prognostic predictors would offer the possibility of selecting patients for different management pathways rather than relying on aortic diameter alone [10]. Finally the management of small AAAs remains controversial despite randomised controlled trials indicating that open surgical repair of 40-55mm AAAs does not reduce mortality [6,7]. Many centres manage all AAAs ≤55mms conservatively. Estimates based on the UK small aneurysm trial support repeat imaging for 30-40, 41-45, 46-50 and 51-55mm AAAs at 24, 12, 6 and 3 monthly intervals respectively [10]. The increasingly utilisation of endovascular repair of AAA, with its lower peri-operative mortality, has been suggested as more appropriate management for small AAAs, particularly those in the 50-55mm range [14,15]. At present however no randomised controlled trial has been completed examining the outcome of endovascular repair of small AAAs, although one such study is expected to report soon [16]. The lack of any proven medical therapy for prevention of progression and rupture of AAAs represents an important challenge [17]. Only one randomised trial has examined the value of a medication (propranolol) for small AAAs in a cohort of reasonable size (>500 subjects) [18].
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grundy, S. M., Cleeman, J. I., Merz, C. N. B., Brewer, H. B., Clark, L. T., Hunninghake, D. B., Pasternak, R. C., Smith, S. C., & Stone, N. J. (2004) · Circulation · doi:10.1161/01.cir.0000133317.49796.0e · Cited by 6,902
Greenhalgh, R. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16979-1 · Cited by 2,011
Grundy, S. M., Cleeman, J. I., Bairey Merz, C. N., Brewer, H. B., Clark, L. T., Hunninghake, D. B., Pasternak, R. C., Smith, S. C., & Stone, N. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.001 · Cited by 1,550
Immediate Repair Compared with Surveillance of Small Abdominal Aortic Aneurysms
Lederle, F. A., Wilson, S. E., Johnson, G. R., Reinke, D. B., Littooy, F. N., Acher, C. W., Ballard, D. J., Messina, L. M., Gordon, I. L., Chute, E. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012573 · Cited by 1,089
Prevalence and Associations of Abdominal Aortic Aneurysm Detected through Screening
Lederle, F. A., Johnson, G. R., Wilson, S. E., Chute, E. P., Littooy, F. N., Bandyk, D., Krupski, W. C., Barone, G. W., Acher, C. W., & Ballard, D. J. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-6-199703150-00004 · Cited by 915
Mining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Risk Factors for Aneurysm Rupture in Patients Kept Under Ultrasound Surveillance
Brown, L. C., & Powell, J. T. (1999) · Annals of Surgery · doi:10.1097/00000658-199909000-00002 · Cited by 703
Abdominal Aortic Aneurysm Expansion: Risk Factors and Time Intervals for Surveillance
Brady, A. R., Thompson, S. G., Fowkes, F. G. R., Greenhalgh, R. M., & Powell, J. T. (2004) · Circulation · doi:10.1161/01.cir.0000133279.07468.9f · Cited by 685
Inflammation and Matrix Metalloproteinases in the Enlarging Abdominal Aortic Aneurysm
Freestone, T., Turner, R. J., Coady, A., Higman, D. J., Greenhalgh, R. M., & Powell, J. T. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.15.8.1145 · Cited by 683
Cited by
Chaikof, E. L., Dalman, R. L., Eskandari, M. K., Jackson, B. M., Lee, W. A., Mansour, M. A., Mastracci, T. M., Mell, M., Murad, M. H., Nguyen, L. L., et al. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2017.10.044 · Cited by 2,751
Self-citationSiu, S. C., & Silversides, C. K. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.068 · Cited by 1,028
2024 ESC Guidelines for the management of peripheral arterial and aortic diseases
Mazzolai, L., Teixido-Tura, G., Lanzi, S., Boc, V., Bossone, E., Brodmann, M., Bura-Rivière, A., De Backer, J., Deglise, S., Della Corte, A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae179 · Cited by 993
Abdominal aortic aneurysm: update on pathogenesis and medical treatments
Golledge, J. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0114-9 · Cited by 788
Self-citationChaikof, E. L., Brewster, D. C., Dalman, R. L., Makaroun, M. S., Illig, K. A., Sicard, G. A., Timaran, C. H., Upchurch, G. R., & Veith, F. J. (2009) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2009.07.002 · Cited by 732
Self-citation
Metadata
- Authors
- Golledge, J., Tsao, P. S., Dalman, R. L., & Norman, P. E.
- Venue
- Circulation
- Published
- 2008-12-02
- Volume
- 118
- Issue
- 23
- Pages
- 2382-2392
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2092056011
- Cited by
- 258
- References
- 78
- FWCI
- 16.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Circulating Markers of Abdominal Aortic Aneurysm Presence and Progression. https://app.cochat.ai/papers/10.1161/circulationaha.108.802074
- The paper
- Golledge, J., Tsao, P. S., Dalman, R. L., & Norman, P. E. (2008). Circulating Markers of Abdominal Aortic Aneurysm Presence and Progression. Circulation. https://doi.org/10.1161/circulationaha.108.802074
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.