Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Early Stent Thrombosis in Patients With Acute Coronary Syndromes Treated With Drug-Eluting and Bare Metal Stents: The Acute Catheterization and Urgent Intervention Triage Strategy Trial

Open access
Aoki, Jiro, Lansky, Alexandra J., Mehran, Roxana, Moses, Jeffery, Bertrand, Michel E., McLaurin, Brent T., Cox, David A., Lincoff, A. Michael, Ohman, E. Magnus, White, Harvey D., Parise, Helen, Leon, Martin B., Stone, Gregg W. · 2009 · Circulation

Abstract

Background— The clinical and angiographic predictors of early (<30 days) stent thrombosis (ST) have not been reported in high-risk patients with acute coronary syndromes. Methods and Results— Qualitative and quantitative coronary angiographic analyses were performed in 3405 patients with moderate- and high-risk acute coronary syndromes in whom stents were implanted in the prospective randomized Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trial, including 3043 patients (89.4%) in whom drug-eluting stents were implanted. Within 30 days, definite or probable ST occurred in 48 patients (1.4%). ST rates were not significantly different in patients treated with bare metal stents compared with drug-eluting stents (1.4% versus 1.4%; P =1.00) or with heparin plus glycoprotein IIb/IIIa inhibitors (1.1%) compared with bivalirudin with or without IIb/IIIa inhibitors (1.6% and 1.5%, respectively; P =0.26 and P =0.37, respectively). Compared with patients without ST, patients with ST more frequently had insulin-requiring diabetes mellitus and baseline renal insufficiency, a greater overall burden of coronary atherosclerosis, and suboptimal final angiographic results. ST also was more common in patients without preprocedural thienopyridine administration and with inconsistent antiplatelet drug use within 30 days. By multivariable analysis, the strongest independent predictors of definite ST were a smaller final stent minimal lumen diameter, a lack of preprocedural thienopyridine administration, the extent of coronary artery disease, and higher baseline hemoglobin level. Conclusions— Occurring in nearly 1 in 70 patients, early ST is relatively common in acute coronary syndromes, occurs with similar frequency after anticoagulation with either heparin plus glycoprotein IIb/IIIa inhibitors or bivalirudin with or without IIb/IIIa inhibitors, and is predicted by diffuse atherosclerosis, suboptimal angiographic results, and inadequate pharmacotherapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.804203

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 186

Metadata

Authors
Aoki, J., Lansky, A. J., Mehran, R., Moses, J., Bertrand, M. E., McLaurin, B. T., Cox, D. A., Lincoff, A. M., Ohman, E. M., White, H. D., Parise, H., Leon, M. B., & Stone, G. W.
Venue
Circulation
Published
2009-02-10
Volume
119
Issue
5
Pages
687-698
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2054420707
Cited by
186
References
1
FWCI
28.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.