Open access
Lopshire, John C., Zhou, Xiaohong, Dusa, Cristian, Ueyama, Takeshi, Rosenberger, Joshua, Courtney, Nicole, Ujhelyi, Michael, Mullen, Thomas, Das, Mithilesh, Zipes, Douglas P.·2009·Circulation

Abstract

Background— Spinal cord stimulation (SCS) reduces the incidence of ventricular tachyarrhythmias in experimental models. This study investigated the effects of long-term SCS on ventricular function in a postinfarction canine heart failure model. Methods and Results— In stage 1, dogs underwent implantable cardioverter-defibrillator implantation and embolization of the left anterior descending artery followed by right ventricular pacing (240 ppm) for 3 weeks to produce heart failure. In stage 2, 28 surviving animals were assigned to the SCS (delivered at the T4/T5 spinal region for 2 hours 3 times a day), medicine (MED; carvedilol therapy at 12.5 mg PO BID), or control (CTRL; no therapy) group for the initial phase 1 study. In a subsequent phase 2 study, 32 stage 1 survivors were equally randomized to the SCS, MEDS (carvedilol plus ramipril 2.5 mg PO QD), SCS plus MEDS (concurrent therapy), or CTRL group. Animals were monitored for 5 weeks (phase 1) or 10 weeks (phase 2). In stage 3, all phase 1 animals underwent circumflex artery balloon occlusion for 1 hour. In the SCS group, left ventricular ejection fraction was 65±5% at baseline, 17±3% at the end of stage 1, and 47±7% at the end of stage 2. In the MED group, left ventricular ejection fraction was 61±4% at baseline, 18±3% at the end of stage 1, and 34±4% at the end of stage 2. In the CTRL group, left ventricular ejection fraction was 64±5% at baseline, 19±5% at the end of stage 1, and 28±3% at the end of stage 2. Left ventricular ejection fraction was significantly improved in the SCS compared with the MED and CTRL groups ( P <0.001 for both). The mean number of spontaneous nonsustained ventricular tachyarrhythmias during stage 2 and the occurrence of ischemic ventricular tachyarrhythmias during stage 3 also were significantly decreased in the SCS (27±17 and 27%, respectively; P <0.03) and MED (58±42 and 33%; P <0.05) versus CTRL (88±52 and 76%) group. After 10 weeks in the phase 2 studies, the greatest recovery in ejection fraction was noted in the SCS (52±5%) and SCS+MEDS (46±4%) groups compared with the MEDS (38±2%) and CTRL (31±4%) groups. Conclusion— SCS significantly improved cardiac contractile function and decreased ventricular arrhythmias in canine heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.812412

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 161

Metadata

Authors
Lopshire, J. C., Zhou, X., Dusa, C., Ueyama, T., Rosenberger, J., Courtney, N., Ujhelyi, M., Mullen, T., Das, M., & Zipes, D. P.
Venue
Circulation
Published
2009-07-28
Volume
120
Issue
4
Pages
286-294
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2077490419
Cited by
161
References
3
FWCI
6.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spinal Cord Stimulation Improves Ventricular Function and Reduces Ventricular Arrhythmias in a Canine Postinfarction Heart Failure Model. https://app.cochat.ai/papers/10.1161/circulationaha.108.812412
The paper
Lopshire, J. C., Zhou, X., Dusa, C., Ueyama, T., Rosenberger, J., Courtney, N., Ujhelyi, M., Mullen, T., Das, M., & Zipes, D. P. (2009). Spinal Cord Stimulation Improves Ventricular Function and Reduces Ventricular Arrhythmias in a Canine Postinfarction Heart Failure Model. Circulation. https://doi.org/10.1161/circulationaha.108.812412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.