Cited by 209ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.

Ambulatory Arrhythmia Monitoring: Choosing the Right Device

Zimetbaum, Peter, Goldman, Alena·2010·Circulation

Abstract

R emote cardiac telemetry was developed to allow home ECG monitoring of patients with suspected cardiac arrhythmias.It was first introduced by the American biophysicist Norman J. Holter (1914 -1983) in the 1940s.The original Holter monitor was a 75-lb backpack with a reel-to-reel FM tape recorder, analog patient interface electronics, and large batteries.1,2 It could record a single ECG lead for several hours and provided the first opportunity to record and analyze ambulatory ECG data outside a standard hospital or outpatient care setting.The clinical need to monitor outpatients has resulted in advances in technology that now allow us to monitor heart rhythms remotely through a wide variety of devices, including ambulatory external monitors, implantable event recorders, pacemakers, and cardioverter-defibrillators.The rapid expansion of ambulatory monitoring technologies affords the clinician the obvious diagnostic advantage of more comprehensive and real-time data.It also presents the challenge of creating systems to handle and pay for this increased information and the potential liability associated with a continuous data stream.This review focuses on the available technology and factors that guide the choice of monitor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.925610

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 35 references

1 of the 35 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Items 201–209 of 209

Metadata

Authors
Zimetbaum, P., & Goldman, A.
Affiliations
Beth Israel Deaconess Medical Center (US)
Venue
Circulation
Published
2010-10-19
Volume
122
Issue
16
Pages
1629-1636
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1991071650
Cited by
209
References
35
Citations by year
2026: 13 · 2025: 9 · 2024: 11 · 2023: 16 · 2022: 12 · 2021: 23 · 2020: 10 · 2019: 20 · 2018: 10 · 2017: 18 · 2016: 16 · 2015: 14 · 2014: 14 · 2013: 13 · 2012: 6
FWCI
1.24
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
Holter monitoring, cardiac arrhythmias, electrocardiogram
MeSH terms
Arrhythmias, Cardiac, Electrocardiography, Humans, Monitoring, Physiologic, Pacemaker, Artificial, Electrocardiography, Ambulatory, Defibrillators, Implantable

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review