The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Abstract
R emote cardiac telemetry was developed to allow home ECG monitoring of patients with suspected cardiac arrhythmias.It was first introduced by the American biophysicist Norman J. Holter (1914 -1983) in the 1940s.The original Holter monitor was a 75-lb backpack with a reel-to-reel FM tape recorder, analog patient interface electronics, and large batteries.1,2 It could record a single ECG lead for several hours and provided the first opportunity to record and analyze ambulatory ECG data outside a standard hospital or outpatient care setting.The clinical need to monitor outpatients has resulted in advances in technology that now allow us to monitor heart rhythms remotely through a wide variety of devices, including ambulatory external monitors, implantable event recorders, pacemakers, and cardioverter-defibrillators.The rapid expansion of ambulatory monitoring technologies affords the clinician the obvious diagnostic advantage of more comprehensive and real-time data.It also presents the challenge of creating systems to handle and pay for this increased information and the potential liability associated with a continuous data stream.This review focuses on the available technology and factors that guide the choice of monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Continuous ECG monitoring longer than the traditional 24to 48-hour duration might improve the diagnostic yield of infrequent arrhythmias.”
From Diagnostic utility of a novel leadless arrhythmia monitoring device. (2013) · cites this paper as [3]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 566
Capucci, A., Santini, M., Padeletti, L., Gulizia, M. M., Botto, G., Boriani, G., Ricci, R. P., Favale, S., Zolezzi, F., Belardino, N. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 400
Liao, J., Khalid, Z., Scallan, C., Morillo, C., & O’Donnell, M. (2007) · Stroke · doi:10.1161/strokeaha.106.478685 · Cited by 331
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Kinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Cited by
Sorted by citations
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Seet, R. C. S., Friedman, P. A., & Rabinstein, A. A. (2011) · Circulation · doi:10.1161/circulationaha.111.029801 · Cited by 274
Diagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Self-citationZIMETBAUM, P. J. (2017) · Annals of Internal Medicine · doi:10.7326/aitc201703070 · Cited by 248
Self-citationElectrocardiographic patch devices and contemporary wireless cardiac monitoring
Fung, E., Järvelin, M., Doshi, R. N., Shinbane, J. S., Carlson, S. K., Grazette, L. P., Chang, P. M., Sangha, R. S., Huikuri, H. V., & Peters, N. S. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00149 · Cited by 191
Bhaskar, S. M. M., Bradley, S., Chattu, V. K., Adisesh, A., Nurtazina, A., Kyrykbayeva, S., Sakhamuri, S. M., Moguilner, S., Pandya, S., Schroeder, S., et al. (2020) · Frontiers in Public Health · doi:10.3389/fpubh.2020.00410 · Cited by 188
Oh, S. L., Ng, E. Y. K., Tan, R., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.12.012 · Cited by 179
Novel Wireless Devices for Cardiac Monitoring
Walsh, J. A., Topol, E. J., & Steinhubl, S. R. (2014) · Circulation · doi:10.1161/circulationaha.114.009024 · Cited by 175
Ambulatory External Electrocardiographic Monitoring
Mittal, S., Movsowitz, C., & Steinberg, J. S. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.07.026 · Cited by 136
Sick sinus syndrome: a review.
Semelka, M., Gera, J., & Usman, S. (2013) · PubMed · Cited by 134
Holter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 124
Kaasenbrood, F., Hollander, M., Rutten, F. H., Gerhards, L. J., Hoes, A. W., & Tieleman, R. G. (2016) · EP Europace · doi:10.1093/europace/euv426 · Cited by 119
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 123
Steinberg, C., Philippon, F., Sánchez, M., Fortier-Poisson, P., O’Hara, G. E., Molin, F., SARRAZIN, J., Nault, I., Blier, L. E., Roy, K., et al. (2019) · Biosensors · doi:10.3390/bios9010017 · Cited by 108
Flexible sensors and machine learning for heart monitoring
Kwon, S. H., & Dong, L. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107632 · Cited by 99
Verberk, W., Omboni, S., Kollias, A., & Stergiou, G. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.10.182 · Cited by 89
Current and Future Use of Insertable Cardiac Monitors
Giancaterino, S., Lupercio, F. A., Nishimura, M., & Hsu, J. C. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.06.001 · Cited by 81
Use of smartphone technology in cardiology
Nguyen, H. H., & Silva, J. N. A. (2015) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2015.11.002 · Cited by 79
SPEAR Trial: Smartphone Pediatric ElectrocARdiogram Trial
Nguyen, H. H., Van Hare, G. F., Rudokas, M., Bowman, T., & Silva, J. N. A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0136256 · Cited by 66
Cardiovascular disease in systemic sclerosis
Nordin, A. (2014) · Figshare · Cited by 68
Arrhythmia and Sudden Death in Hemodialysis Patients
Charytan, D. M., Foley, R. N., McCullough, P. A., Rogers, J., ZIMETBAUM, P. J., Herzog, C. A., & Tumlin, J. A. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.09350915 · Cited by 67
Self-citationSchreiber, D., Sattar, A., Drigalla, D., & Higgins, S. (2014) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2013.11.18973 · Cited by 65
Multiscale Analysis of Intensive Longitudinal Biomedical Signals and Its Clinical Applications
Nakamura, T., Kiyono, K., Wendt, H., Abry, P., & Yamamoto, Y. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2491979 · Cited by 64
Detection and classification of arrhythmia using an explainable deep learning model
Jo, Y., Kwon, J., Jeon, K., Cho, Y.-H., Shin, J. H., Lee, Y.-J., Jung, M., Ban, J., Kim, K., Lee, S. Y., et al. (2021) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2021.06.006 · Cited by 57
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Albers, G. W., Bernstein, R. A., Brachmann, J., Camm, A. J., Easton, J. D., Fromm, P., Goto, S., Granger, C. B., Hohnloser, S. H., Hylek, E. M., et al. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002944 · Cited by 54
Point-of-Care Technologies for Precision Cardiovascular Care and Clinical Research
King, K. R., Grazette, L. P., Paltoo, D. N., McDevitt, J. T., Sia, S. K., Barrett, P. M., Apple, F. S., Gurbel, P. A., Weissleder, R., Leeds, H. S., et al. (2016) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2016.01.008 · Cited by 54
Moing, A. G. L., Seferian, A., Moraux, A., Annoussamy, M., Dorveaux, É., Gasnier, E., Hogrel, J., Voït, T., Vissière, D., & Servais, L. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156696 · Cited by 52
Prognostic significance of ambulatory ECG monitoring for ventricular arrhythmias
Katritsis, D. G., Siontis, G. C. M., & Camm, A. J. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.07.005 · Cited by 44
Optimal Duration of Monitoring for Atrial Fibrillation in Cryptogenic Stroke: A Nonsystematic Review
Hariri, E. H., Hachem, A. A., Sarkis, G., & Nasr, S. (2016) · BioMed Research International · doi:10.1155/2016/5704963 · Cited by 47
Al‐Khatib, S. M. (2023) · Annals of Internal Medicine · doi:10.7326/aitc202307180 · Cited by 41
Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis
Lee, W. K., Yoon, H., & Park, K. S. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1502-5 · Cited by 41
Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children
Bolourchi, M., Silver, E. S., Muwanga, D., Mendez, E., & Liberman, L. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.11.028 · Cited by 41
Ambulatory Arrhythmia Detection with ZIO® XT Patch in Pediatric Patients: A Comparison of Devices
Pradhan, S., Robinson, J. A., Shivapour, J., & Snyder, C. S. (2019) · Pediatric Cardiology · doi:10.1007/s00246-019-02089-0 · Cited by 40
Bladder Monitoring Systems: State of the Art and Future Perspectives
Semproni, F., Iacovacci, V., & Menciassi, A. (2022) · IEEE Access · doi:10.1109/access.2022.3221816 · Cited by 42
Karaoğuz, M. R., Yurtseven, E., Aslan, G., Deliormanlı, B. G., Adıgüzel, Ö., Gönen, M., Li, K.-M., & Yılmaz, E. N. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.02.012 · Cited by 39
Izmailova, E. S., McLean, L., Hather, G., Merberg, D., Homsy, J. G., Cantor, M., Volfson, D., Bhatia, G., Perakslis, E. D., Benko, C., et al. (2019) · Clinical and Translational Science · doi:10.1111/cts.12673 · Cited by 38
Eysenck, W., Freemantle, N., & Sulke, N. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00515-0 · Cited by 36
Kohno, R., Abe, H., & Benditt, D. G. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.04.012 · Cited by 35
Bolourchi, M., & Batra, A. S. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.12.014 · Cited by 34
Visual Feedback of Continuous Bedside Pressure Mapping to Optimize Effective Patient Repositioning
Scott, R. G., & Thurman, K. (2014) · Advances in Wound Care · doi:10.1089/wound.2013.0519 · Cited by 34
Nedios, S., Romero, I., Gerds‐Li, J., FLECK, E., & Kriatselis, C. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.04.003 · Cited by 31
Choi, W., Kim, S., Lee, W., Kang, S., Yoon, C., Youn, T., & Chae, I. (2020) · Journal of Korean Medical Science · doi:10.3346/jkms.2020.35.e363 · Cited by 30
Signal Quality Analysis for Long-Term ECG Monitoring Using a Health Patch in Cardiac Patients
Campero-Jurado, I., Lorato, I. R., Morales, J., Fruytier, L., Stuart, S., Panditha, P., Janssen, D. M., Rossetti, N., Uzunbajakava, N. E., Șerban, I. B., et al. (2023) · Sensors · doi:10.3390/s23042130 · Cited by 30
Phillips, J. S., Newman, J. L., & Cox, S. J. (2019) · Scientific Reports · doi:10.1038/s41598-019-46970-7 · Cited by 28
Multi-purpose ECG telemetry system
Marouf, M., Vukomanović, G., Saranovac, L. V., & Bozic, M. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0371-6 · Cited by 27
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 26
State of the art of mobile health technologies use in clinical arrhythmia care
Sridhar, A. R. M., Cheung, J. W., Lampert, R., Silva, J. N. A., Gopinathannair, R., Sotomonte, J. C., Tarakji, K. G., Fellman, M., Chrispin, J., Varma, N., et al. (2024) · Communications Medicine · doi:10.1038/s43856-024-00618-4 · Cited by 30
Heartbeat Classification with Spiking Neural Networks on the Loihi Neuromorphic Processor
Buettner, K., & George, A. D. (2021) · IEEE Computer Society Annual Symposium on VLSI · doi:10.1109/isvlsi51109.2021.00035 · Cited by 23
Cardiac monitoring for patients with palpitations
Pascual, J. F., Romero, J. C., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Maldonado, J., González, I. F., & Rivas‐Gándara, N. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i11.608 · Cited by 23
Park, M. H. K., de Asmundis, C., Chierchia, G., Sarkozy, A., Benatar, A. A., & Brugada, P. (2011) · EP Europace · doi:10.1093/europace/eur159 · Cited by 23
Smart watch applications in atrial fibrillation detection: Current state and future directions
Vyas, R., Jain, S., Thakre, A., Thotamgari, S. R., Raina, S., Brar, V., Sengupta, P. P., & Agrawal, P. K. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16451 · Cited by 22
Automating anxiety detection using respiratory signal analysis
Haritha, H., Negi, S., Menon, R., Kumar, A. A., & Kumar, C. S. (2017) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tenconspring.2017.8069995 · Cited by 21
Characterization of Single Lead Continuous ECG Recording with Various Dry Electrodes
Hassan, M. F. U., Lai, D., & Bu, Y. (2019) · International Conference on Computational Biology and Bioinformatics (ICCBB) · doi:10.1145/3365966.3365974 · Cited by 21
Textile Building Blocks: Toward Simple, Modularized, and Standardized Smart Textile
Cheng, J., Zhou, B., Lukowicz, P., Seoane, F., Varga, M., Mehmann, A., Chabreček, P., Gaschler, W., Gönner, K., Horter, H., et al. (2017) · Human-computer interaction series · doi:10.1007/978-3-319-50124-6_14 · Cited by 20
A Novel Patch for Heart Rhythm Monitoring: is the Holter Monitor obsolete?
Higgins, S. L. (2013) · Future Cardiology · doi:10.2217/fca.13.13 · Cited by 19
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Secondary Stroke Prevention: Improving Diagnosis and Management with Newer Technologies
Imam, Y. Z. B., D’Souza, A., Malik, R. A., & Shuaib, A. M. (2016) · Translational Stroke Research · doi:10.1007/s12975-016-0494-2 · Cited by 18
External Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Garikapati, K., Turnbull, S., Bennett, R. G., Campbell, T. G., Kanawati, J., Wong, M. S., Thomas, S. P., Chow, C. K., & Kumar, S. (2022) · Heart Lung and Circulation · doi:10.1016/j.hlc.2022.08.001 · Cited by 18
Graphene nanostructures for input–output bioelectronics
Garg, R., Roman, D. S., Wang, Y., Cohen-Karni, D., & Cohen‐Karni, T. (2021) · Biophysics Reviews · doi:10.1063/5.0073870 · Cited by 16
Shrivastav, M., Padte, S., Arora, V., & Biffi, M. (2013) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2013.867807 · Cited by 16
Adebayo, R. A., Ikwu, A. N., Balogun, M. O., Akintomide, A. O., Ajayi, O. E., Adeyeye, V. O., Mene-Afejuku, T. O., Bamikole, O. J., Ogunyemi, S. A., Ajibare, A. O., et al. (2015) · Vascular Health and Risk Management · doi:10.2147/vhrm.s81106 · Cited by 16
Supraventricular tachycardia diagnosed by smartphone ECG
Tabing, A. K., Harrell, T., Romero, S. C., & Francisco, G. M. (2017) · BMJ Case Reports · doi:10.1136/bcr-2016-217197 · Cited by 16
Benditt, D. G., Adkisson, W. O., Sutton, R., Mears, R. K., & Sakaguchi, S. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13265 · Cited by 16
Romero, I. (2013) · Cardiology in Review · doi:10.1097/crd.0b013e31828a8294 · Cited by 16
Usadel, L., Haverkämper, G., Herrmann, S., Löber, R., Weiß, K., Opgen‐Rhein, B., Berger, F. F., & Will, J. C. (2015) · Pediatric Cardiology · doi:10.1007/s00246-015-1304-4 · Cited by 15
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Reasons for Hospitalization Among Emergency Department Patients With Syncope
Cook, O., Mukarram, M. A., Rahman, O. M., Kim, S., Arcot, K., Thavorn, K., Taljaard, M., Sivilotti, M. L. A., Rowe, B. H., & Thiruganasambandamoorthy, V. (2016) · Academic Emergency Medicine · doi:10.1111/acem.13053 · Cited by 14
The Case of the Migrating Loop Recorder
Hasnie, A. A., Hasnie, A. A., & Assaly, R. (2019) · JACC Case Reports · doi:10.1016/j.jaccas.2019.06.020 · Cited by 14
Design of a real-time morphology-based anomaly detection method from ECG streams
Ngo, D., & Veeravalli, B. (2015) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2015.7359793 · Cited by 13
Innovative Cardiac Devices on Chest Imaging
Brixey, A. G., & Fuss, C. (2017) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000304 · Cited by 13
Using a Cardiac Event Recorder in Children with Potentially Arrhythmia‐Related Symptoms
Saygı, M., Ergül, Y., Özyılmaz, İ., Şengül, F. S., Güvenç, O., Aslan, E., Güzeltaş, A., Akdeniz, C., & Tuzcu, V. (2016) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12339 · Cited by 12
Newham, W. G., & Tayebjee, M. H. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1514 · Cited by 12
Monteiro, R., Rabello, G. D. C. M., Moreno, C. R., Moitinho, M. S., Pires, F. A., Samesina, N., César, L. A. M., Tarasoutchi, F., Fernandes, F., Martins, P., et al. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1443998 · Cited by 11
Paroxysmal atrial fibrillation after ischemic stroke: how should we hunt for it?
Abdul‐Rahim, A. H., & Lees, K. R. (2013) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.13.21 · Cited by 11
Cryptogenic Stroke And Role Of Loop Recorder.
Pérez‐Rodon, J., Pascual, J. F., Rivas‐Gándara, N., Roca‐Luque, I., Bellera, N., & Moya‐Mitjans, À. (2014) · PubMed Central · doi:10.4022/jafib.1178 · Cited by 11
Pascual, J. F., Santos‐Ortega, A., Roca‐Luque, I., Rivas‐Gándara, N., Pérez‐Rodon, J., Milà, L., David Garcia-dorado, A., & Moya‐Mitjans, À. (2018) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2018.04.007 · Cited by 12
The AFLETES Study: Atrial Fibrillation in Veteran Athletes and the Risk of Stroke
Pallikadavath, S., Richards, C. E., Bountziouka, V., Sandilands, A., Graham-Brown, M. P. M., Robinson, T. G., Singh, A., & McCann, G. P. (2023) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0000000000001115 · Cited by 12
Pascual, J. F., Santos‐Ortega, A., Roca‐Luque, I., Rivas‐Gándara, N., Pérez‐Rodon, J., Milà, L., David Garcia-dorado, A., & Moya‐Mitjans, À. (2018) · Revista Española de Cardiología · doi:10.1016/j.recesp.2018.04.013 · Cited by 9
Kwun, J.-S., Lee, J. H., Park, B. E., Park, J. S., Kim, H. J., Kim, S., Jeon, K., Cho, H.-W., Kang, S., Lee, W., et al. (2023) · Journal of Medical Internet Research · doi:10.2196/45760 · Cited by 9
New Technologies for Detection and Management of Atrial Fibrillation
Hamad, A. K. (2021) · Journal of the Saudi Heart Association · doi:10.37616/2212-5043.1256 · Cited by 10
Ooteghem, K. V., Godkin, F. E., Thai, V., Beyer, K. B., Cornish, B. F., Weber, K. S., Bernstein, H., Kheiri, S. O., Swartz, R. H., Tan, B., et al. (2023) · Digital Health · doi:10.1177/20552076231179031 · Cited by 9
Feature normalization for enhancing early detection of cardiac disorders
Negi, S., Kumar, C. S., & Kumar, A. A. (2016) · IEEE India Conference · doi:10.1109/indicon.2016.7838937 · Cited by 9
Lelakowska-Pieła, M., Komar, M., Matusik, P. T., Nessler, J. M., Podolec, P. S., & Olszowska, M. (2018) · Kardiologia Polska · doi:10.5603/kp.a2018.0149 · Cited by 9
Tang, H., Yan, M., Wu, X., Lai, H., Zhang, Y., Cui, H., & Xie, L. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.109101 · Cited by 8
Kim, S., Lim, J., Shin, M., & Jung, S. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340882 · Cited by 8
Effect of the recording condition on the quality of a single-lead electrocardiogram
Hamada, S., Sasaki, K., Kito, H., Tooyama, Y., Ihara, K., Aoyagi, E., Ichimura, N., Tohda, S., & Sasano, T. (2021) · Heart and Vessels · doi:10.1007/s00380-021-01991-z · Cited by 9
Context-Aware Support for Cardiac Health Monitoring Using Federated Machine Learning
Ogbuabor, G. O., Augusto, J. C., Moseley, R., & van Wyk, A. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-91100-3_22 · Cited by 8
Dahlqvist, J. A., Karlsson, M., Wiklund, U., Hörnsten, R., & Rydberg, A. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.02.006 · Cited by 8
An Engineering Perspective of External Cardiac Loop Recorder: A Systematic Review
Srinivasulu, A., & Sriraam, N. (2016) · Journal of Medical Engineering · doi:10.1155/2016/6931347 · Cited by 8
Hardon, H. J., Kerkhof, Y. N. V., Bartelds, B., Kammeraad, J. A. E., & van Deutekom, A. W. (2025) · JMIR Formative Research · doi:10.2196/70835 · Cited by 9
Advancements in Sensor Technology for Monitoring and Management of Chronic Coronary Syndrome
Cricco, R., Segreti, A., Ferro, A., Beato, S., Castaldo, G., Ciancio, M., Sacco, F. M., Pennazza, G., Ussia, G. P., & Grigioni, F. (2025) · Sensors · doi:10.3390/s25154585 · Cited by 9
Artificial Intelligence in Cardiovascular Diseases
Bashir, S., Ahanger, A. N., Assad, A., Bhat, M. R., & Macha, M. A. (2025) · Springer eBooks · doi:10.1007/978-981-96-8176-1_10 · Cited by 8
Altinsoy, M., Sutton, R., Kohno, R., Sakaguchi, S., Mears, R. K., & Benditt, D. G. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12560 · Cited by 7
Akça, T., Uysal, F., Bostan, Ö., Genç, A., & Türkmen, H. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02705-y · Cited by 7
On-device Prior Knowledge Incorporated Learning for Personalized Atrial Fibrillation Detection
Jia, Z., Shi, Y., Saba, S., & Hu, J. (2021) · ACM Transactions on Embedded Computing Systems · doi:10.1145/3476987 · Cited by 7
Arnold, R. J. G., & Layton, A. J. (2015) · Journal of health economics and outcomes research · doi:10.36469/9897 · Cited by 7
Redesigning the Trans-disciplinary
Heiss, L., Beckett, P., & Bottomley, A. C. (2016) · Designing Interactive Systems Conference · doi:10.1145/2901790.2901794 · Cited by 7
Metadata
- Authors
- Zimetbaum, P., & Goldman, A.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- ORCID
- Zimetbaum, Peter
- Venue
- Circulation
- Published
- 2010-10-19
- Volume
- 122
- Issue
- 16
- Pages
- 1629-1636
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1991071650
- Cited by
- 209
- References
- 35
- Citations by year
- 2026: 13 · 2025: 9 · 2024: 11 · 2023: 16 · 2022: 12 · 2021: 23 · 2020: 10 · 2019: 20 · 2018: 10 · 2017: 18 · 2016: 16 · 2015: 14 · 2014: 14 · 2013: 13 · 2012: 6
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- Holter monitoring, cardiac arrhythmias, electrocardiogram
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Humans, Monitoring, Physiologic, Pacemaker, Artificial, Electrocardiography, Ambulatory, Defibrillators, Implantable
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review