The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: The European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve
Open accessAbstract
Background—: Transcatheter aortic valve implantation was developed to provide a therapeutic option for patients considered to be ineligible for, and to mitigate mortality and morbidity associated with, high-risk surgical aortic valve replacement. Methods and Results—: The Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess initial post commercial clinical transcatheter aortic valve implantation results of the Edwards SAPIEN valve in consecutive patients in Europe. Cohort 1 consists of 1038 patients enrolled at 32 centers. One-year outcomes are presented. Patients with the transapical approach (n=575) suffered more comorbidities than transfemoral patients (n=463) with a significantly higher logistic EuroSCORE (29% versus 25.8%; P =0.007). These groups are different; therefore, outcomes cannot be directly compared. Total Kaplan Meier 1-year survival was 76.1% overall, 72.1% for transapical and 81.1% for transfemoral patients, and 73.5% of surviving patients were in New York Heart Association (NYHA) class I or II at 1 year. Combined transapical and transfemoral causes of death were cardiac in 25.1%, noncardiac in 49.2%, and unknown in 25.7%. Pulmonary complications (23.9%), renal failure (12.5%), cancer (11.4%), and stroke (10.2%) were the most frequent noncardiac causes of death. Multivariable analysis identified logistic EuroSCORE, renal disease, liver disease, and smoking as variables with the highest hazard ratios for 1-year mortality whereas carotid artery stenosis, hyperlipidemia, and hypertension were associated with lower mortality. Conclusion—: The SOURCE Registry is the largest consecutively enrolled registry for transcatheter aortic valve implantation procedures. It demonstrates that with new transcatheter aortic techniques excellent 1-year survival in high-risk and inoperable patients is achievable and provides a benchmark against which future transcatheter aortic valve implantation cohorts and devices can be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charlson, M. E., Pompei, P., Ales, K. L., & MacKenzie, C. R. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90171-8 · Cited by 49,742
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Roques, F. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00106-2 · Cited by 1,759
The Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 2—Isolated Valve Surgery
O'Brien, S. M., Shahian, D. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S.-L. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.056 · Cited by 1,259
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Rodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Self-citationStandardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience
Walther, T., Simon, P., Dewey, T., Wimmer-Greinecker, G., Falk, V., Kasimir, M. T., Doss, M., Borger, M. A., Schuler, G., Glogar, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.677237 · Cited by 618
Self-citationKahlert, P., Knipp, S. C., Schlamann, M., Thielmann, M., Al-Rashid, F., Weber, M., Johansson, U., Wendt, D., Jakob, H. G., Forsting, M., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.855866 · Cited by 521
Self-citationCoronary artery bypass grafting: The Society of Thoracic Surgeons National Database experience
Edwards, F. H., Clark, R. E., & Schwartz, M. (1994) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(94)90358-1 · Cited by 418
Dewey, T. M., Brown, D., Ryan, W. H., Herbert, M. A., Prince, S. L., & Mack, M. J. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.09.011 · Cited by 405
One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
Lefevre, T., Kappetein, A. P., Wolner, E., Nataf, P., Thomas, M., Schachinger, V., De Bruyne, B., Eltchaninoff, H., Thielmann, M., Himbert, D., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq427 · Cited by 376
Self-citationRisk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation
Ghanem, A., Müller, A., Nähle, C. P., Kocurek, J., Werner, N., Hammerstingl, C., Schild, H. H., Schwab, J. O., Mellert, F., Fimmers, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.026 · Cited by 345
Svensson, L. G., Dewey, T., Kapadia, S., Roselli, E. E., Stewart, A., Williams, M., Anderson, W. N., Brown, D., Leon, M., Lytle, B., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.04.049 · Cited by 278
Transapical minimally invasive aortic valve implantation; the initial 50 patients☆
Walther, T., Falk, V., Kempfert, J., Borger, M. A., Fassl, J., Chu, M. W. A., Schuler, G., & Mohr, F. W. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.01.046 · Cited by 255
Self-citationAortic Valve Replacement in Octogenarians: Utility of Risk Stratification With EuroSCORE
Leontyev, S., Walther, T., Borger, M. A., Lehmann, S., Funkat, A. K., Rastan, A., Kempfert, J., Falk, V., & Mohr, F. W. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.01.057 · Cited by 207
Self-citationMorbidity during hospitalization: Can we predict it?
Charlson, M. E., Sax, F. L., Mackenzie, C. R., Braham, R. L., Fields, S. D., & Douglas, R. G. (1987) · Journal of Chronic Diseases · doi:10.1016/0021-9681(87)90107-x · Cited by 169
Transapical transcatheter aortic valve implantation: Follow-up to 3 years
Ye, J., Cheung, A. W., Lichtenstein, S. V., et al. (2010) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.10.056 · Cited by 119
EuroSCORE Performance in Valve Surgery: A Meta-Analysis
Parolari, A., Pesce, L. L., Trezzi, M., Cavallotti, L., Kassem, S., Loardi, C. M., Pacini, D., Tremoli, E., & Alamanni, F. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.11.032 · Cited by 105
Wendler, O., Walther, T., Nataf, P., Rubino, P., Schroefel, H., Thielmann, M., Treede, H., & Thomas, M. (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.12.048 · Cited by 86
Self-citationWalther, T., Kasimir, M., Doss, M., Schuler, G. C., Simon, P., Schächinger, V., Mohr, F. W., & Wimmer‐Greinecker, G. (2010) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2010.06.002 · Cited by 63
Self-citationSevere Aortic Stenosis in a Veteran Population: Treatment Considerations and Survival
Bakaeen, F. G., Chu, D., Ratcliffe, M. B., Gopaldas, R. R., Blaustein, A., Venkat, R., Huh, J., LeMaire, S. A., Coselli, J. S., & Carabello, B. A. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.10.033 · Cited by 39
The EuroSCORE – still helpful in patients undergoing isolated aortic valve replacement?☆
Wendt, D., OSSWALD, B. R., Thielmann, M., Kayser, K., Tossios, P., Massoudy, P., Kamler, M., & Jakob, H. G. (2009) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.218149 · Cited by 22
Cited by
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Self-citationGuidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationKapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Metadata
- Authors
- Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Colombo, A., Lange, R., Schwarz;, R. R., & Wendler, O.
- Venue
- Circulation
- Published
- 2011-07-26
- Volume
- 124
- Issue
- 4
- Pages
- 425-433
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2163581622
- Cited by
- 524
- References
- 25
- FWCI
- 65.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.