Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 900

The DOI matches its Crossref record.

Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery

Open access
Webb, John G., Chandavimol, Mann, Thompson, Christopher R., Ricci, Donald R., Carere, Ronald G., Munt, Brad I., Buller, Christopher E., Pasupati, Sanjeevan, Lichtenstein, Samuel·2006·Circulation

Abstract

Background— Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. Methods and Results— The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81±6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6±0.2 to 1.6±0.4 cm 2 . There were no intraprocedural deaths. At follow-up of 75±55 days, 16 patients (89%) remained alive. Conclusions— This initial experience suggests that percutaneous transarterial aortic valve implantation is feasible in selected high-risk patients with satisfactory short-term outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.582882

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 900

Metadata

Authors
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S.
Venue
Circulation
Published
2006-02-14
Volume
113
Issue
6
Pages
842-850
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2148154533
Cited by
900
References
0
FWCI
55.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery. https://app.cochat.ai/papers/10.1161/circulationaha.105.582882
The paper
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006). Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery. Circulation. https://doi.org/10.1161/circulationaha.105.582882

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.