Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 755

The DOI matches its Crossref record.

Cardiac Troponin T Measured by a Highly Sensitive Assay Predicts Coronary Heart Disease, Heart Failure, and Mortality in the Atherosclerosis Risk in Communities Study

Open access
Saunders, Justin T., Nambi, Vijay, de Lemos, James A., Chambless, Lloyd E., Virani, Salim S., Boerwinkle, Eric, Hoogeveen, Ron C., Liu, Xiaoxi, Astor, Brad C., Mosley, Thomas H., Folsom, Aaron R., Heiss, Gerardo, Coresh, Josef, Ballantyne, Christie M.·2011·Circulation

Abstract

Background—: We evaluated whether cardiac troponin T (cTnT) measured with a new highly sensitive assay was associated with incident coronary heart disease (CHD), mortality, and hospitalization for heart failure (HF) in a general population of participants in the Atherosclerosis Risk in Communities (ARIC) Study. Methods and Results—: Associations between increasing cTnT levels and CHD, mortality, and HF hospitalization were evaluated with Cox proportional hazards models adjusted for traditional CHD risk factors, kidney function, high-sensitivity C-reactive protein, and N-terminal pro–B-type natriuretic peptide in 9698 participants aged 54 to 74 years who at baseline were free from CHD and stroke (and HF in the HF analysis). Measurable cTnT levels (≥0.003 μg/L) were detected in 66.5% of individuals. In fully adjusted models, compared with participants with undetectable levels, those with cTnT levels in the highest category (≥0.014 μg/L; 7.4% of the ARIC population) had significantly increased risk for CHD (hazard ratio=2.29; 95% confidence interval, 1.81 to 2.89), fatal CHD (hazard ratio=7.59; 95% confidence interval, 3.78 to 15.25), total mortality (hazard ratio=3.96; 95% confidence interval, 3.21 to 4.88), and HF (hazard ratio=5.95; 95% confidence interval, 4.47 to 7.92). Even minimally elevated cTnT (≥0.003 μg/L) was associated with increased risk for mortality and HF ( P <0.05). Adding cTnT to traditional risk factors improved risk prediction parameters; the improvements were similar to those with N-terminal pro–B-type natriuretic peptide and better than those with the addition of high-sensitivity C-reactive protein. Conclusions—: cTnT detectable with a highly sensitive assay was associated with incident CHD, mortality, and HF in individuals from a general population without known CHD/stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.005264

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 755

Metadata

Authors
Saunders, J. T., Nambi, V., de Lemos, J. A., Chambless, L. E., Virani, S. S., Boerwinkle, E., Hoogeveen, R. C., Liu, X., Astor, B. C., Mosley, T. H., Folsom, A. R., Heiss, G., Coresh, J., & Ballantyne, C. M.
Venue
Circulation
Published
2011-04-05
Volume
123
Issue
13
Pages
1367-1376
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2009826381
Cited by
755
References
0
FWCI
41.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Troponin T Measured by a Highly Sensitive Assay Predicts Coronary Heart Disease, Heart Failure, and Mortality in the Atherosclerosis Risk in Communities Study. https://app.cochat.ai/papers/10.1161/circulationaha.110.005264
The paper
Saunders, J. T., Nambi, V., de Lemos, J. A., Chambless, L. E., Virani, S. S., Boerwinkle, E., Hoogeveen, R. C., Liu, X., Astor, B. C., Mosley, T. H., Folsom, A. R., Heiss, G., Coresh, J., & Ballantyne, C. M. (2011). Cardiac Troponin T Measured by a Highly Sensitive Assay Predicts Coronary Heart Disease, Heart Failure, and Mortality in the Atherosclerosis Risk in Communities Study. Circulation. https://doi.org/10.1161/circulationaha.110.005264

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.