Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 310

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation Patterns

Open access
Cuculich, Phillip S., Wang, Yong, Lindsay, Bruce D., Faddis, Mitchell N., Schuessler, Richard B., Damiano, Ralph J., Li, Li, Rudy, Yoram · 2010 · Circulation

Abstract

Background—: Various mechanisms of atrial fibrillation (AF) have been demonstrated experimentally. Invasive methods to study these mechanisms in humans have limitations, precluding continuous mapping of both atria with sufficient resolution. In this article, we present continuous biatrial epicardial activation sequences of AF in humans using noninvasive electrocardiographic imaging (ECGI). Methods and Results—: In the testing phase, ECGI accuracy was evaluated by comparing ECGI with coregistered CARTO images during atrial pacing in 6 patients. Additionally, correlative observations from catheter mapping and ablation were compared with ECGI in 3 patients. In the study phase, ECGI maps during AF in 26 patients were analyzed for mechanisms and complexity. ECGI noninvasively imaged the low-amplitude signals of AF in a wide range of patients (97 procedural success). Spatial accuracy for determining initiation sites from pacing was 6 mm. Locations critical to maintenance of AF identified during catheter ablation were identified by ECGI; ablation near these sites restored sinus rhythm. In the study phase, the most common patterns of AF were multiple wavelets (92), with pulmonary vein (69) and non–pulmonary vein (62) focal sites. Rotor activity was seen rarely (15). AF complexity increased with longer clinical history of AF, although the degree of complexity of nonparoxysmal AF varied widely. Conclusions—: ECGI offers a noninvasive way to map epicardial activation patterns of AF in a patient-specific manner. The results highlight the coexistence of a variety of mechanisms and variable complexity among patients. Overall, complexity generally increased with duration of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.945709

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 310

Metadata

Authors
Cuculich, P. S., Wang, Y., Lindsay, B. D., Faddis, M. N., Schuessler, R. B., Damiano, R. J., Li, L., & Rudy, Y.
Venue
Circulation
Published
2010-10-05
Volume
122
Issue
14
Pages
1364-1372
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2127986259
Cited by
310
References
54
FWCI
14.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation Patterns. https://app.cochat.ai/papers/10.1161/circulationaha.110.945709
The paper
Cuculich, P. S., Wang, Y., Lindsay, B. D., Faddis, M. N., Schuessler, R. B., Damiano, R. J., Li, L., & Rudy, Y. (2010). Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation Patterns. Circulation. https://doi.org/10.1161/circulationaha.110.945709

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.