Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cryoablation Versus Radiofrequency Energy for the Ablation of Atrioventricular Nodal Reentrant Tachycardia (the CYRANO Study): Results From a Large Multicenter Prospective Randomized Trial

Open access
Deisenhofer, Isabel, Zrenner, Bernhard, Yin, Yue-hui, Pitschner, Heinz-Friedrich, Kuniss, Malte, Großmann, Georg, Stiller, Sascha, Luik, Armin, Veltmann, Christian, Frank, Julia, Linner, Julia, Estner, Heidi L., Pflaumer, Andreas, Wu, Jinjin, von Bary, Christian, Ücer, Ekrem, Reents, Tilko, Tzeis, Stylianos, Fichtner, Stephanie, Kathan, Susanne, Karch, Martin R., Jilek, Clemens, Ammar, Sonia, Kolb, Christof, Liu, Zeng-Chang, Haller, Bernhard, Schmitt, Claus, Hessling, Gabriele · 2010 · Circulation

Abstract

Background—: Cryoablation has emerged as an alternative to radiofrequency catheter ablation (RFCA) for the treatment of atrioventricular (AV) nodal reentrant tachycardia (AVNRT). The purpose of this prospective randomized study was to test whether cryoablation is as effective as RFCA during both short-term and long-term follow-up with a lower risk of permanent AV block. Methods and Results—: A total of 509 patients underwent slow pathway cryoablation (n=251) or RFCA (n=258). The primary end point was immediate ablation failure, permanent AV block, and AVNRT recurrence during a 6-month follow-up. Secondary end points included procedural parameters, device functionality, and pain perception. Significantly more patients in the cryoablation group than the RFCA group reached the primary end point (12.6% versus 6.3%; P =0.018). Whereas immediate ablation success (96.8% versus 98.4%) and occurrence of permanent AV block (0% versus 0.4%) did not differ, AVNRT recurrence was significantly more frequent in the cryoablation group (9.4% versus 4.4%; P =0.029). In the cryoablation group, procedure duration was longer (138±54 versus 123±48 minutes; P =0.0012) and more device problems occurred (13 versus 2 patients; P =0.033). Pain perception was lower in the cryoablation group ( P <0.001). Conclusions—: Cryoablation for AVNRT is as effective as RFCA over the short term but is associated with a higher recurrence rate at the 6-month follow-up. The risk of permanent AV block does not differ significantly between cryoablation and RFCA. The potential benefits of cryoenergy relative to ablation safety and pain perception are counterbalanced by longer procedure times, more device problems, and a high recurrence rate. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00196222.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.970350

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Untitled work

    Blomstrom-Lundqvist (2003) · doi:10.1161/01.cir.0000091380.04100.84 · Cited by 955

Show all 1 references

Cited by

Metadata

Authors
Deisenhofer, I., Zrenner, B., Yin, Y.-H., Pitschner, H.-F., Kuniss, M., Großmann, G., Stiller, S., Luik, A., Veltmann, C., Frank, J., Linner, J., Estner, H. L., Pflaumer, A., Wu, J., von Bary, C., Ücer, E., Reents, T., Tzeis, S., Fichtner, S., Kathan, S., Karch, M. R., Jilek, C., Ammar, S., Kolb, C., Liu, Z.-C., Haller, B., Schmitt, C., & Hessling, G.
Venue
Circulation
Published
2010-11-30
Volume
122
Issue
22
Pages
2239-2245
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2063781457
Cited by
170
References
1
FWCI
9.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.