The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices
Open accessAbstract
B ecause of the obligate intravascular location of contem- porary continuous-flow ventricular assist devices (CF-VADs), it is not surprising that bleeding and thrombosis are among the most common and feared complications of this therapy, respectively.Although strides have been made in our understanding of the pathophysiology of continuous flow, intravascular CF-VADs have been widely used only in the last few years, and a great deal remains less well known (or unknown).Outcomes have improved significantly over the past decade, but a deeper understanding of how these devices perturb the delicate intrinsic balance of bleeding and thrombosis is critical to guide therapy and to overcome the current obstacles to achieving a long-term safety profile comparable to that of mechanical prosthetic valves. Pathophysiology Hematologic Effect of CF-VADsThe hematologic effects of CF-VADs are of significant interest and importance and have recently been reviewed in detail elsewhere.1,2 Hemocompatibility refers to the interaction of prosthetic material with blood and can be measured in terms of impact on hematologic, inflammatory, or immunologic parameters, which has been observed clinically as significant and prolonged activation of endothelial and coagulation systems after CF-VAD implantation, including intercellular adhesion molecule, E-selectin, and tissue factor, for example.3 Hemocompatibility has always been a goal in pump design, along with efforts to maximize blood flow without clinically significant hemolysis, areas of stasis, turbulent flow, or retrograde flow.It has been suggested that the major complications of thrombosis, bleeding, and infection could be related to the effects of blood interaction with the VAD surface, 4,5 and further optimization of surface coatings presents an appealing strategy for additional exploration.6 A better understanding of the impact of blood-VAD surface interactions with the presently used CF-VAD devices, however, is essential to evaluating the impact of novel designs or materials.A few recent observations have provided some insight into the impact of CF-VAD on the hematologic system.The 2 areas with the most data available are acquired von Willebrand disease and platelet activation.We also comment on preliminary findings on the potential role of microparticles. von Willebrand FactorThe finding that has garnered the most attention is the loss of large von Willebrand factor (vWF) multimers, much like Heyde syndrome as described in patients with critical aortic stenosis.7 High shear stress has previously been noted to alter the 3-dimensional structure and to enhance proteolysis of the vWF by ADAMTS-13, 8 -10 a plausible mechanism in the setting of increased shear stress with CF-VADs (see Figure 1A).Veyradier et al 12 noted a high rate of von Willebrand disease in patients with bleeding angiodysplasia without a VAD and proposed that this deficiency was particularly pertinent at the very high shear conditions related to these malformations.In sharp contrast to heart transplant recipients, Geisen et al 13 first reported loss of large vWF multimers in patients supported with HeartMate II and pulsatile VADs despite amounts of vWF antigen that were comparable to that seen in heart transplant recipients (Figure 1B).Impaired collagen binding capacity and ristocetin cofactor activity, a measure of vWF factor binding to platelets, were also lower in all VAD patients.This finding has been confirmed by other groups, 11,14,15 observed to occur within the first few days after left VAD (LVAD) implantation, 16 and noted to resolve after LVAD explantation.17 In contrast to the initial report, 13 others have found altered vWF multimers in CF-VADs but not pulsatile VADs, 18 and altered vWF multimers have been documented after exchange from pulsatile VAD to CF-VAD.19 A small study of CardioWest total artificial heart implants did not find evidence of decreased large vWF multimers in the first year after implantation, 20 but we are unaware of data after prolonged (Ͼ1 year) support or with AbioCor total artificial heart.Taken together, the flow characteristics of a CF-VAD may be a critical factor, but limited and conflicting data on the impact of pulsatile-flow devices suggest that additional factors may be operative.Patients with blood type O have been noted to have lower baseline levels of vWF compared with other blood groups, and 1 study found evidence of frequent bleeding in patients with blood group O. 11 A similar rate was noted in patients with groups B and AB, and a study of coronary artery bypass patients did not
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Self-citationExtended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
Pagani, F. D., Miller, L. W., Russell, S. D., Aaronson, K. D., John, R., Boyle, A. J., Conte, J. V., Bogaev, R. C., MacGillivray, T. E., Naka, Y., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.055 · Cited by 869
Self-citationEndothelial von Willebrand factor regulates angiogenesis
Starke, R. D., Ferraro, F., Paschalaki, K. E., Dryden, N. H., McKinnon, T. A. J., Sutton, R. E., Payne, E. M., Haskard, D. O., Hughes, A. D., Cutler, D. F., et al. (2011) · Blood · doi:10.1182/blood-2010-01-264507 · Cited by 512
Crow, S., John, R., Boyle, A., Shumway, S., Liao, K., Colvin-Adams, M., Toninato, C., Missov, E., Pritzker, M., Martin, C., et al. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.07.032 · Cited by 486
Self-citationStarling, R. C., Naka, Y., Boyle, A. J., Gonzalez-Stawinski, G., John, R., Jorde, U., Russell, S. D., Conte, J. V., Aaronson, K. D., McGee, E. C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.062 · Cited by 452
Self-citationShear stress enhances the proteolysis of von Willebrand factor in normal plasma
Tsai, H., Sussman, II, & Nagel, R. (1994) · Blood · doi:10.1182/blood.v83.8.2171.2171 · Cited by 422
Demirozu, Z. T., Radovancevic, R., Hochman, L. F., Gregoric, I. D., Letsou, G. V., Kar, B., Bogaev, R. C., & Frazier, O. H. (2011) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2011.03.008 · Cited by 356
Geisen, U., Heilmann, C., Beyersdorf, F., Benk, C., Berchtold-Herz, M., Schlensak, C., Budde, U., & Zieger, B. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2007.12.047 · Cited by 331
Boyle, A. J., Russell, S. D., Teuteberg, J. J., Slaughter, M. S., Moazami, N., Pagani, F. D., Frazier, O. H., Heatley, G., Farrar, D. J., & John, R. (2009) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2009.05.018 · Cited by 300
Self-citationLetsou, G. V., Shah, N., Gregoric, I. D., Myers, T. J., Delgado, R., & Frazier, O. H. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2003.10.018 · Cited by 217
Lazar, R. M., Shapiro, P. A., Jaski, B. E., Parides, M. K., Bourge, R. C., Watson, J. T., Damme, L., Dembitsky, W., Hosenpud, J. D., Gupta, L., et al. (2004) · Circulation · doi:10.1161/01.cir.0000129414.95137.cd · Cited by 158
Immunologic sensitization in recipients of left ventricular assist devices
John, R., Lietz, K., Schuster, M., Naka, Y., Rao, V., MANCINI, D. M., Rose, E. A., Smith, C. R., Öz, M. C., Edwards, N. M., et al. (2003) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.30 · Cited by 139
Self-citationMicroparticles: Key Protagonists in Cardiovascular Disorders
Amabile, N., Rautou, P., Tedgui, A., & Boulanger, C. M. (2010) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0030-1267044 · Cited by 136
Platelet Dysfunction in Outpatients With Left Ventricular Assist Devices
Steinlechner, B., Dworschak, M., Birkenberg, B., Duris, M., Zeidler, P., Fischer, H., Milošević, L., Wieselthaler, G. M., Wolner, E., Quehenberger, P., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.10.027 · Cited by 134
Lahpor, J. R., Khaghani, A., Hetzer, R., Pavie, A., Friedrich, I., Sander, K., & Strüber, M. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.05.043 · Cited by 128
Cerebrovascular accidents in patients with a ventricular assist device
Tsukui, H., Abla, A. A., Teuteberg, J. J., McNamara, D. M., Mathier, M. A., Cadaret, L., & Kormos, R. L. (2007) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.02.044 · Cited by 117
Activation of Endothelial and Coagulation Systems in Left Ventricular Assist Device Recipients
John, R., Panch, S. R., Hrabe, J. E., Wei, P., Solovey, A. N., Joyce, L. D., & Hebbel, R. P. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.06.095 · Cited by 116
Self-citationSurface coatings for ventricular assist devices
Sin, D., Kei, H.-L., & Miao, X. (2008) · Elsevier eBooks · doi:10.1533/9780857093677.2.264 · Cited by 108
The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate
Stissing, T., Dridi, N., Ostrowski, S. R., Bochsen, L., & Johansson, P. I. (2011) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/1076029610397183 · Cited by 102
Von Willebrand Factor, ADAMTS-13, and Thrombotic Thrombocytopenic Purpura
Zhou, Z., Nguyen, T., Guchhait, P., et al. (2010) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0030-1248726 · Cited by 50
Small intestine capsule endoscopy in magnetic suspended axial left ventricular assist device patient
Garatti, A. (2005) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2005.116871 · Cited by 30
Majeed, F., Kop, W. J., Poston, R., Kallam, S., & Mehra, M. R. (2009) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1441 · Cited by 26
Cited by
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
Braunwald, E. (2013) · JACC: Heart Failure · doi:10.1016/j.jchf.2012.10.002 · Cited by 730
Metadata
- Authors
- Eckman, P. M., & John, R.
- Venue
- Circulation
- Published
- 2012-06-19
- Volume
- 125
- Issue
- 24
- Pages
- 3038-3047
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2060021951
- Cited by
- 299
- References
- 23
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.