Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Mutations in Cytoplasmic Loops of the KCNQ1 Channel and the Risk of Life-Threatening Events: Implications for Mutation-Specific Response to β-Blocker Therapy in Type 1 Long-QT Syndrome

Open access
Barsheshet, Alon, Goldenberg, Ilan, O-Uchi, Jin, Moss, Arthur J., Jons, Christian, Shimizu, Wataru, Wilde, Arthur A., McNitt, Scott, Peterson, Derick R., Zareba, Wojciech, Robinson, Jennifer L., Ackerman, Michael J., Cypress, Michael, Gray, Daniel A., Hofman, Nynke, Kanters, Jorgen K., Kaufman, Elizabeth S., Platonov, Pyotr G., Qi, Ming, Towbin, Jeffrey A., Vincent, G. Michael, Lopes, Coeli M. · 2012 · Circulation

Abstract

Background—: β-Adrenergic stimulation is the main trigger for cardiac events in type 1 long-QT syndrome (LQT1). We evaluated a possible association between ion channel response to β-adrenergic stimulation and clinical response to β-blocker therapy according to mutation location. Methods and Results—: The study sample comprised 860 patients with genetically confirmed mutations in the KCNQ1 channel. Patients were categorized into carriers of missense mutations located in the cytoplasmic loops (C loops), membrane-spanning domain, C/N terminus, and nonmissense mutations. There were 27 aborted cardiac arrest and 78 sudden cardiac death events from birth through 40 years of age. After multivariable adjustment for clinical factors, the presence of C-loop mutations was associated with the highest risk for aborted cardiac arrest or sudden cardiac death (hazard ratio versus nonmissense mutations=2.75; 95% confidence interval, 1.29–5.86; P =0.009). β-Blocker therapy was associated with a significantly greater reduction in the risk of aborted cardiac arrest or sudden cardiac death among patients with C-loop mutations than among all other patients (hazard ratio=0.12; 95% confidence interval, 0.02–0.73; P =0.02; and hazard ratio=0.82; 95% confidence interval, 0.31–2.13; P =0.68, respectively; P for interaction=0.04). Cellular expression studies showed that membrane spanning and C-loop mutations produced a similar decrease in current, but only C-loop mutations showed a pronounced reduction in channel activation in response to β-adrenergic stimulation. Conclusions—: Patients with C-loop missense mutations in the KCNQ1 channel exhibit a high risk for life-threatening events and derive a pronounced benefit from treatment with β-blockers. Reduced channel activation after sympathetic activation can explain the increased clinical risk and response to therapy in patients with C-loop mutations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.111.048041

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 202

Metadata

Authors
Barsheshet, A., Goldenberg, I., O-Uchi, J., Moss, A. J., Jons, C., Shimizu, W., Wilde, A. A., McNitt, S., Peterson, D. R., Zareba, W., Robinson, J. L., Ackerman, M. J., Cypress, M., Gray, D. A., Hofman, N., Kanters, J. K., Kaufman, E. S., Platonov, P. G., Qi, M., Towbin, J. A., Vincent, G. M., & Lopes, C. M.
Venue
Circulation
Published
2012-04-24
Volume
125
Issue
16
Pages
1988-1996
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2099551120
Cited by
202
References
4
FWCI
14.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.