Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation
Abstract
Background—: We investigated the impact of catheter ablation on ventricular tachycardia (VT) recurrence and survival in a large number of patients with structural heart disease treated in the setting of a dedicated multiskilled unit. Methods and Results—: Since January 2007, we have implemented a multidisciplinary model, aiming for a comprehensive management of VT patients. Programmed ventricular stimulation was used to assess acute outcome. Primary end points were VT recurrence and the occurrence of cardiac and sudden cardiac death. Overall, 528 patients were treated by ablation (634 procedures; 1–4 procedures per patient). Among 482 tested with programmed ventricular stimulation after the last procedure, a class A result (noninducibility of any VT) was obtained in 371 patients (77%), class B (inducibility of nondocumented VT) in 12.4%, and class C (inducibility of index VT) in 10.6%. After a median follow-up time of 26 months, VT recurred in 164 (34.1%) of 472 patients. VT recurrence was documented in 28.6% of patients with a class A result versus 39.6% of patients with class B and 66.7% with class C result (log-rank P <0.001). The incidence of cardiac mortality was lower in class A patients than in those with class B and class C (8.4% versus 18.5% versus 22%, respectively; log-rank P =0.002). On the basis of multivariate analysis, postprocedural inducibility of index VT was independently associated both with VT recurrence (hazard ratio, 4.030; P <0.001) and with cardiac mortality (hazard ratio, 2.099; P =0.04). Conclusions—: Within a dedicated VT unit, catheter ablation prevents long-term VT recurrences, which may favorably affect survival in a large number of patients who have VT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citationZeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Tung, R., Vaseghi, M., Frankel, D. S., Vergara, P., Di Biase, L., Nagashima, K., Yu, R., Vangala, S., Tseng, C.-H., Choi, E.-K., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.036 · Cited by 499
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Metadata
- Authors
- Bella, P. D., Baratto, F., Tsiachris, D., Trevisi, N., Vergara, P., Bisceglia, C., Petracca, F., Carbucicchio, C., Benussi, S., Maisano, F., Alfieri, O., Pappalardo, F., Zangrillo, A., & Maccabelli, G.
- Venue
- Circulation
- Published
- 2013-04-02
- Volume
- 127
- Issue
- 13
- Pages
- 1359-1368
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2042255748
- Cited by
- 189
- References
- 4
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation. https://app.cochat.ai/papers/10.1161/circulationaha.112.000872
- The paper
- Bella, P. D., Baratto, F., Tsiachris, D., Trevisi, N., Vergara, P., Bisceglia, C., Petracca, F., Carbucicchio, C., Benussi, S., Maisano, F., Alfieri, O., Pappalardo, F., Zangrillo, A., & Maccabelli, G. (2013). Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation. Circulation. https://doi.org/10.1161/circulationaha.112.000872
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.