Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 189

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation

Bella, Paolo Della, Baratto, Francesca, Tsiachris, Dimitris, Trevisi, Nicola, Vergara, Pasquale, Bisceglia, Caterina, Petracca, Francesco, Carbucicchio, Corrado, Benussi, Stefano, Maisano, Francesco, Alfieri, Ottavio, Pappalardo, Federico, Zangrillo, Alberto, Maccabelli, Giuseppe · 2013 · Circulation

Abstract

Background—: We investigated the impact of catheter ablation on ventricular tachycardia (VT) recurrence and survival in a large number of patients with structural heart disease treated in the setting of a dedicated multiskilled unit. Methods and Results—: Since January 2007, we have implemented a multidisciplinary model, aiming for a comprehensive management of VT patients. Programmed ventricular stimulation was used to assess acute outcome. Primary end points were VT recurrence and the occurrence of cardiac and sudden cardiac death. Overall, 528 patients were treated by ablation (634 procedures; 1–4 procedures per patient). Among 482 tested with programmed ventricular stimulation after the last procedure, a class A result (noninducibility of any VT) was obtained in 371 patients (77%), class B (inducibility of nondocumented VT) in 12.4%, and class C (inducibility of index VT) in 10.6%. After a median follow-up time of 26 months, VT recurred in 164 (34.1%) of 472 patients. VT recurrence was documented in 28.6% of patients with a class A result versus 39.6% of patients with class B and 66.7% with class C result (log-rank P <0.001). The incidence of cardiac mortality was lower in class A patients than in those with class B and class C (8.4% versus 18.5% versus 22%, respectively; log-rank P =0.002). On the basis of multivariate analysis, postprocedural inducibility of index VT was independently associated both with VT recurrence (hazard ratio, 4.030; P <0.001) and with cardiac mortality (hazard ratio, 2.099; P =0.04). Conclusions—: Within a dedicated VT unit, catheter ablation prevents long-term VT recurrences, which may favorably affect survival in a large number of patients who have VT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.112.000872

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 189

Metadata

Authors
Bella, P. D., Baratto, F., Tsiachris, D., Trevisi, N., Vergara, P., Bisceglia, C., Petracca, F., Carbucicchio, C., Benussi, S., Maisano, F., Alfieri, O., Pappalardo, F., Zangrillo, A., & Maccabelli, G.
Venue
Circulation
Published
2013-04-02
Volume
127
Issue
13
Pages
1359-1368
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2042255748
Cited by
189
References
4
FWCI
14.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation. https://app.cochat.ai/papers/10.1161/circulationaha.112.000872
The paper
Bella, P. D., Baratto, F., Tsiachris, D., Trevisi, N., Vergara, P., Bisceglia, C., Petracca, F., Carbucicchio, C., Benussi, S., Maisano, F., Alfieri, O., Pappalardo, F., Zangrillo, A., & Maccabelli, G. (2013). Management of Ventricular Tachycardia in the Setting of a Dedicated Unit for the Treatment of Complex Ventricular Arrhythmias: Long-Term Outcome After Ablation. Circulation. https://doi.org/10.1161/circulationaha.112.000872

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.