Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement

Van Mieghem, Nicolas M., Schipper, Marguerite E.I., Ladich, Elena, Faqiri, Elham, van der Boon, Robert, Randjgari, Abas, Schultz, Carl, Moelker, Adriaan, van Geuns, Robert-Jan, Otsuka, Fumiyuki, Serruys, Patrick W., Virmani, Renu, de Jaegere, Peter P.·2013·Circulation

Abstract

Background—: Recent transcatheter aortic valve replacement studies have raised concerns about adverse cerebrovascular events. The etiopathology of the embolized material is currently unknown. Methods and Results—: A total of 40 patients underwent transcatheter aortic valve replacement with the use of a dual filter–based embolic protection device (Montage Dual Filter System, Claret Medical, Inc). Macroscopic material liberated during the transcatheter aortic valve replacement procedure was captured in the device filter baskets in 30 (75%) patients and sent for histopathologic analysis. The captured material varied in size from 0.15 to 4.0 mm. Amorphous calcified material (size, 0.55–1.8 mm) was identified in 5 patients (17%). In 8 patients (27%), the captured material (size, 0.25–4.0 mm) contained valve tissue composed of loose connective tissue (collagen and elastic fibers) with focal areas of myxoid stroma, with or without coverage by endothelial cells and intermixed with fibrin. In another 13 (43%) patients, collagenous tissue, which may represent elements of vessel wall and valvelike structures, was identified. In 9 patients (30%), thrombotic material was intermixed with neutrophils (size, 0.15–2.0 mm). Overall, thrombotic material was found in 52% of patients, and tissue fragments compatible with aortic valve leaflet or aortic wall origin were found in 52% (21/40) of patients. Conclusions—: Embolic debris traveling to the brain was captured in 75% of transcatheter aortic valve replacement procedures where a filter-based embolic protection device was used. The debris consisted of fibrin, or amorphous calcium and connective tissue derived most likely from either the native aortic valve leaflets or aortic wall.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.112.001091

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 263

Metadata

Authors
Van Mieghem, N. M., Schipper, M. E. I., Ladich, E., Faqiri, E., van der Boon, R., Randjgari, A., Schultz, C., Moelker, A., van Geuns, R.-J., Otsuka, F., Serruys, P. W., Virmani, R., & de Jaegere, P. P.
Venue
Circulation
Published
2013-06-04
Volume
127
Issue
22
Pages
2194-2201
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2057546425
Cited by
263
References
20
FWCI
16.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.