The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Postprocedural Aortic Regurgitation in Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Replacement Procedures: Analysis of Predictors and Impact on Long-Term Mortality: Insights From the FRANCE2 Registry
Abstract
Background—: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results—: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions—: Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“with some studies even suggesting that this adverse association extends to mild regurgitation235;237;238.”
From Calcific aortic stenosis (2016) · cites this paper as [238]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The association between moderate or severe paravalvular aortic regurgitation and increased mortality has been clearly established”
From Calcific aortic stenosis (2016) · cites this paper as [238]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,375
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,276
Lancellotti, P., Moura, L. M., Piérard, L., Agricola, E., Popescu, B. A., Tribouilloy, C. M., Hagendorff, A., Monin, J.-L., Badano, L. P., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq031 · Cited by 1,554
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,263
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationLeon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M. J., Mehran, R., Miller, D. C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,217
Tamburino, C., Capodanno, D., Ramondo, A. B., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,123
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs255 · Cited by 1,045
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Athappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–241 of 241
Device closure of periprosthetic paravalvular regurgitation
Ghimire, G., Capps, C., & Alli, O. O. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1075387
Belardi, J., & Albertal, M. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26259
Outcomes and Predictors of Mortality After Transcatheter Aortic Valve Implantation: Results of the
Brito, Carvalho, L. A. F., Lemos, P. A., Siciliano, A., Caramori, P., Luiz, S. G., Grube, E., & Abizaid, A. (2015)
Transcatheter aortic valve replacement: Are we ready to expand the use?
Méndiz, O. (2015) · Cardiology Journal · doi:10.5603/cj.2015.0082
Riahi, M., Masson, J., Naim, C., Gobeil, J., Noiseux, N., Stevens, L., Spaziano, M., Piazza, N., Martucci, G. J., de Varennes, B., et al. (2015)
Hell, M. M., Achenbach, S. S., & Arnold, M. B. (2015) · Herz
Rauch, A., Vincent, F., BELLE, E. V., & Susen, S. (2017) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(17)30241-1
Self-citationSchmidt-Salzmann, M., Schlüter, M., Kück, K., & Frerker, C. (2017) · Future Cardiology · doi:10.2217/fca-2017-0035
Chamandi, C., & Rodés‐Cabau, J. (2017) · Springer eBooks · doi:10.1007/978-3-319-59620-4_26
Aortic Regurgitation After Transcatheter Aortic Valve Implantation
Borz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-05912-5_14
Reith, S., & Napp, A. (2019) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/a-0835-7851
Transcatheter aortic valve replacement: potential use in lower-risk aortic stenosis
Laricchia, A., Khokhar, A. A., Gallo, F., Giannini, F., Colombo, A., Latib, A., & Mangieri, A. (2020) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2020.1833717
Impact of Balloon Postdilation on Six-Year Mortality After Transcatheter Aortic Valve Replacement
Shimokawa, A., Yoshitani, K., Hayashi, H., Kakuta, T., Kawamoto, N., Kanzaki, H., Fukushima, S., Fujita, T., Ogata, S., & Ohnishi, Y. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.11.037
Low‐Flow Low‐Gradient Aortic Stenosis
Cardaioli, F., Fraccaro, C., Fabris, T., & Tarantini, G. (2021) · doi:10.1002/9781119720621.ch15
Yamamoto, T., Endo, D., Yamaoka, H., Matsushita, S., Kajimoto, K., Asai, T., & Amano, A. (2021) · Journal of Cardiac Surgery · doi:10.1111/jocs.15513
Peri‐procedural Complications of Transcatheter Aortic Valve Replacement (TAVR)
Khokhar, A. A., Giannini, F., & Colombo, A. (2022) · Interventional Cardiology · doi:10.1002/9781119697367.ch59
Valvular heart disease: state of the art and treatment perspectives
Cribier, A. G., & Eltchaninoff, H. (2017) · doi:10.1093/med/9780198701590.003.0107
Self-citationTranscatheter Aortic Valve Implantation
Messika–Zeitoun, D., & Ureña, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-40125-8.00016-0
Hiltner, E. P., Shah, M., Schwabe-Warf, D., Haik, B. N., Hakeem, A., Russo, M. J., & Sethi, A. (2022) · medRxiv · doi:10.1101/2022.10.16.22281140
杨, 宝. (2022) · Advances in Clinical Medicine · doi:10.12677/acm.2022.12111481
Role of Echocardiography in Guiding Transcatheter Aortic and Mitral Valve Replacement
Bansal, M., & Kasliwal, R. R. (2022) · Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging · doi:10.4103/jiae.jiae_45_22
Tang, Y. (2024) · Springer eBooks · doi:10.1007/978-981-19-7712-1_7
Wang, S., Haozhong, L. I. U., Haijiang, G. U. O., Tan, T., Hanxiang, X. I. E., Liu, X., Hailong, Q. I. U., Chen, J., Huiming, G. U. O., & Jian, L. I. U. (2025) · Journal of Zhejiang University (Medical Sciences) · doi:10.3724/zdxbyxb-2024-0487
Kosugi, S., Mizote, I., Nakamura, D., Sugae, H., Matsuhiro, Y., Okuno, S., Kawamura, A., Yamashita, K., Maeda, K., Shimamura, K., et al. (2025) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.31537
Self-expanding or balloon-expandable valves: a trade-off between paravalvular leak and durability?
BELLE, E. V., Bakhtari, S., & Vincent, F. (2025) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaf148
Ruberti, A. A., Occhipinti, G., Mon-Noboa, M., y, L. N.-F., Tomii, D., Pilgrim, T., Sabaté, M., Estebanez, E., Gonzalo, N., Jiménez‐Quevedo, P., et al. (2025) · Structural Heart · doi:10.1016/j.shj.2025.100730
Wang, B., Mei, Z., Ge, X., Li, Y., Zhou, Q., Meng, X., & An, G. (2023) · Figshare · doi:10.6084/m9.figshare.23812494
Gallo, F., Laricchia, A., Montonati, C., Pellicano, M., Ielasi, A., Tzanis, G., & Giannini, F. (2026) · Springer eBooks · doi:10.1007/978-3-032-04995-7_7
Yeo, T. C. (2026) · Springer eBooks · doi:10.1007/978-981-96-7667-5_8
Müller, A. F., Weber, S., Hoffmann, J., Schneider, L., & Klein, T. (2026) · Bulletin of pioneering researches of medical and clinical science · doi:10.51847/u3lexoyjqc
Jurkowska, K. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.6074
Matsuhiro, Y., Nakamura, D., Ide, S., Higashino, N., Sugae, H., Okuno, S., Kosugi, S., Kawamura, A., Maeda, K., Shimamura, K., et al. (2026) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.70884
Metadata
- Authors
- Van Belle, E., Juthier, F., Susen, S., Vincentelli, A., Iung, B., Dallongeville, J., Eltchaninoff, H., Laskar, M., Leprince, P., Lievre, M., Banfi, C., Auffray, J.-L., Delhaye, C., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leguerrier, A., Prat, A., Gilard, M., & Teiger, E.
- Affiliations
- From the Department of Cardiology, University Hospital, Lille, France (E.V.B., F.J., A.V., C.B., J.-L.A., C.D., A.P.); EA2693, Lille-II-University, Lille, France (E.V.B., F.J., S.S., A.V., C.B., J.-L.A., C.D., A.P.); INSERM-U744, Lille, France (J.D.); CHU Bichat, Paris, France (B.I.); CHU Rouen, Rouen, France (H.E.); CHU Dupuytren, Limoges, France (M. Laskar); CHU Pitié–Salpêtrière, Paris, France (P.L.); University Lyon-1, Lyon, France (M. Lievre; Institut cardiovasculaire Paris-Sud, Paris, France ...
- Inserm (FR)
- ORCID
- Venue
- Circulation
- Published
- 2014-04
- Volume
- 129
- Issue
- 13
- Pages
- 1415-1427
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2025529577
- Cited by
- 241
- References
- 28
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 9 · 2023: 13 · 2022: 19 · 2021: 12 · 2020: 31 · 2019: 18 · 2018: 22 · 2017: 22 · 2016: 25 · 2015: 37 · 2014: 13
- FWCI
- 22.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, balloon-expandable valves, self-expanding valves, aortic annulus size, transfemoral access, one-year mortality
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Echocardiography, Female, Follow-Up Studies, France, Heart Valve Prosthesis, Humans, Longitudinal Studies, Male, Postoperative Complications, Predictive Value of Tests, Prognosis, Registries, Time Factors, Incidence, Survival Rate, Treatment Outcome, Heart Valve Prosthesis Implantation, Balloon Valvuloplasty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review