The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Postprocedural Aortic Regurgitation in Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Replacement Procedures: Analysis of Predictors and Impact on Long-Term Mortality: Insights From the FRANCE2 Registry
Abstract
Background—: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results—: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions—: Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“with some studies even suggesting that this adverse association extends to mild regurgitation235;237;238.”
From Calcific aortic stenosis (2016) · cites this paper as [238]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The association between moderate or severe paravalvular aortic regurgitation and increased mortality has been clearly established”
From Calcific aortic stenosis (2016) · cites this paper as [238]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,375
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,276
Lancellotti, P., Moura, L. M., Piérard, L., Agricola, E., Popescu, B. A., Tribouilloy, C. M., Hagendorff, A., Monin, J.-L., Badano, L. P., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq031 · Cited by 1,554
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,263
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationLeon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M. J., Mehran, R., Miller, D. C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,217
Tamburino, C., Capodanno, D., Ramondo, A. B., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,123
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs255 · Cited by 1,045
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Athappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M. J., Mehran, R., Miller, D. C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 736
Lancellotti, P., Tribouilloy, C., Hagendorff, A., Moura, L., Popescu, B. A., Agricola, E., Monin, J. L., Pierard, L. A., Badano, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq030 · Cited by 501
Abdel‐Wahab, M., Zahn, R., Horack, M., Gerckens, U. J., Schuler, G. C., Sievert, H., Eggebrecht, H., Senges, J., Richardt, G., & for the German transcatheter aortic valve interventions registry investigators (2011) · Heart · doi:10.1136/hrt.2010.217158 · Cited by 472
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau‐Gouge, P., Chevreul, K., Fajadet, J. C., Leprince, P. N., Leguerrier, A., Lièvre, M. M., Prat, A. G., et al. (2013) · Survey of Anesthesiology · doi:10.1097/01.sa.0000426523.25196.4e · Cited by 454
Self-citationMultimodal Assessment of the Aortic Annulus Diameter
Messika–Zeitoun, D., Serfaty, J., Brochet, É., Ducrocq, G., Lepage, L., Détaint, D., Hyafil, F., Himbert, D., Pasi, N., Laissy, J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.063 · Cited by 421
Self-citationDeterminants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
Détaint, D., Lepage, L., Himbert, D., Brochet, É., Messika–Zeitoun, D., Iung, B., & Vahanian, A. S. (2009) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2009.07.003 · Cited by 384
Self-citationBoon, A., Cheriex, E. C., Lodder, J., & Kessels, F. (1997) · Heart · doi:10.1136/hrt.78.5.472 · Cited by 347
Sherif, M., Abdel‐Wahab, M., Stöcker, B., Geist, V., Richardt, D., Tölg, R., & Richardt, G. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.035 · Cited by 257
y, L. N.-F., Rodés‐Cabau, J., DeLarochellière, R., Larose, É., Doyle, D., Villeneuve, J., Bergeron, S., Bernier, M., Amat-Santos, I. J., Mok, M. T. C., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.02.010 · Cited by 220
Hayashida, K., Lefèvre, T., Chevalier, B., Hovasse, T., Romano, M., Garot, P., Bouvier, E., Farge, A., Donzeau‐Gouge, P., Cormier, B., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.09.003 · Cited by 169
Self-citationTransapical Aortic Valve Implantation
Unbehaun, A., Pašić, M., Dreysse, S. T., Drews, T., Kukucka, M., Mladenow, A., Ivanitskaja-Kühn, E., Hetzer, R., & Buz, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.857 · Cited by 162
Takagi, K., Latib, A., Al-Lamee, R. K., Mussardo, M., Montorfano, M., Maisano, F., Godino, C., Chieffo, A., Alfieri, O., & Colombo, A. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23003 · Cited by 153
Impact of Metabolic Syndrome on Progression of Aortic Stenosis
Capoulade, R., Clavel, M.-A., Dumesnil, J. G., Chan, K. L., Teo, K. K., Tam, J. W., Côté, N., Mathieu, P., Després, J.-P., & Pibarot, P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.052 · Cited by 127
Gotzmann, M., Korten, M., Bojara, W., Lindstaedt, M., Rahlmann, P., Mügge, A., & Ewers, A. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.07.010 · Cited by 114
Impact of Paravalvular Leakage on Outcome in Patients After Transcatheter Aortic Valve Implantation
Vasa‐Nicotera, M., Sinning, J., Chin, D. T., Lim, T. K., Spyt, T. J., Jilaihawi, H., Grube, E., Werner, N., Nickenig, G., & Kovac, J. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.04.011 · Cited by 104
y, L. N.-F., Ruel, M., Radhakrishnan, S., Webb, J. G., Hansen, M., Labinaz, M. X., Thompson, C., Fremes, S. E., Dumont, É., DeLarochellière, R., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.11.063 · Cited by 85
Doppler echocardiographic evaluation of prosthetic valve function
Pîbarot, P., & Dumesnil, J. G. (2011) · Heart · doi:10.1136/heartjnl-2011-300351 · Cited by 54
Mohty, D., Pibarot, P., Després, J.-P., Cartier, A., Arsenault, B., Picard, F., & Mathieu, P. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.12.068 · Cited by 53
Flagged first, then by citations
Cited by
Sorted by citations
Lindman, B. R., Clavel, M.-A., Mathieu, P., Iung, B., Lancellotti, P., Otto, C. M., & Pibarot, P. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.6 · Cited by 982
Self-citationTranscatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis
Thyregod, H. G. H., Steinbrüchel, D. A., Ihlemann, N., Nissen, H., Kjeldsen, B. J., Pétursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.014 · Cited by 934
Global Public Health Burden of Heart Failure: An Updated Review
Shahim, B., Kapelios, C., Savarese, G., & Lund, L. (2023) · Cardiac failure review · doi:10.15420/cfr.2023.05 · Cited by 655
Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu384 · Cited by 446
Siontis, G. C. M., Praz, F., Pilgrim, T., Mavridis, D., Verma, S., Salanti, G., Søndergaard, L., Jüni, P., & Windecker, S. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw225 · Cited by 358
Metadata
- Authors
- Van Belle, E., Juthier, F., Susen, S., Vincentelli, A., Iung, B., Dallongeville, J., Eltchaninoff, H., Laskar, M., Leprince, P., Lievre, M., Banfi, C., Auffray, J.-L., Delhaye, C., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leguerrier, A., Prat, A., Gilard, M., & Teiger, E.
- Affiliations
- From the Department of Cardiology, University Hospital, Lille, France (E.V.B., F.J., A.V., C.B., J.-L.A., C.D., A.P.); EA2693, Lille-II-University, Lille, France (E.V.B., F.J., S.S., A.V., C.B., J.-L.A., C.D., A.P.); INSERM-U744, Lille, France (J.D.); CHU Bichat, Paris, France (B.I.); CHU Rouen, Rouen, France (H.E.); CHU Dupuytren, Limoges, France (M. Laskar); CHU Pitié–Salpêtrière, Paris, France (P.L.); University Lyon-1, Lyon, France (M. Lievre; Institut cardiovasculaire Paris-Sud, Paris, France ...
- Inserm (FR)
- ORCID
- Venue
- Circulation
- Published
- 2014-04
- Volume
- 129
- Issue
- 13
- Pages
- 1415-1427
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2025529577
- Cited by
- 241
- References
- 28
- Citations by year
- 2026: 7 · 2025: 12 · 2024: 9 · 2023: 13 · 2022: 19 · 2021: 12 · 2020: 31 · 2019: 18 · 2018: 22 · 2017: 22 · 2016: 25 · 2015: 37 · 2014: 13
- FWCI
- 22.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, balloon-expandable valves, self-expanding valves, aortic annulus size, transfemoral access, one-year mortality
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Echocardiography, Female, Follow-Up Studies, France, Heart Valve Prosthesis, Humans, Longitudinal Studies, Male, Postoperative Complications, Predictive Value of Tests, Prognosis, Registries, Time Factors, Incidence, Survival Rate, Treatment Outcome, Heart Valve Prosthesis Implantation, Balloon Valvuloplasty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review