The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Impact on Late Clinical Outcomes and Left Ventricular Function
Open accessAbstract
Background—: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. Methods and Results—: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74–1.30; P =0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56–1.17; P =0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77–1.30; P =0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11–0.85; P =0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time ( P =0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, −2.26; 95% confidence interval, −4.07 to −0.44; P =0.013; R 2 =0.121). Conclusions—: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Biventricular Pacing in Patients with Bradycardia and Normal Ejection Fraction
Yu, C.-M., Chan, J. Y.-S., Zhang, Q., Omar, R., Yip, G. W.-K., Hussin, A., Fang, F., Lam, K. H., Chan, H. C.-K., & Fung, J. W.-H. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0907555 · Cited by 477
Transcatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Self-citation
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Perioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements
Walther, T., Hamm, C. W., Schuler, G., Berkowitsch, A., Kötting, J., Mangner, N., Mudra, H., Beckmann, A., Cremer, J., Welz, A., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.034 · Cited by 402
Metadata
- Authors
- Urena, M., Webb, J. G., Tamburino, C., Muñoz-García, A. J., Cheema, A., Dager, A. E., Serra, V., Amat-Santos, I. J., Barbanti, M., Immè, S., Briales, J. H. A., Benitez, L. M., Al Lawati, H., Cucalon, A. M., García del Blanco, B., López, J., Dumont, E., DeLarochellière, R., Ribeiro, H. B., Nombela-Franco, L., Philippon, F., & Rodés-Cabau, J.
- Venue
- Circulation
- Published
- 2014-03-18
- Volume
- 129
- Issue
- 11
- Pages
- 1233-1243
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2611968684
- Cited by
- 304
- References
- 6
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Impact on Late Clinical Outcomes and Left Ventricular Function. https://app.cochat.ai/papers/10.1161/circulationaha.113.005479
- The paper
- Urena, M., Webb, J. G., Tamburino, C., Muñoz-García, A. J., Cheema, A., Dager, A. E., Serra, V., Amat-Santos, I. J., Barbanti, M., Immè, S., Briales, J. H. A., Benitez, L. M., Al Lawati, H., Cucalon, A. M., García del Blanco, B., López, J., Dumont, E., DeLarochellière, R., Ribeiro, H. B., . . . Rodés-Cabau, J. (2014). Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Impact on Late Clinical Outcomes and Left Ventricular Function. Circulation. https://doi.org/10.1161/circulationaha.113.005479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.