CoChat

Experimentally Increasing Titin Compliance in a Novel Mouse Model Attenuates the Frank-Starling Mechanism But Has a Beneficial Effect on Diastole

Open access
Methawasin, Mei, Hutchinson, Kirk R., Lee, Eun-Jeong, Smith, John E., Saripalli, Chandra, Hidalgo, Carlos G., Ottenheijm, Coen A.C., Granzier, Henk · 2014 · Circulation
Cited by 143

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background—: Experimentally upregulating compliant titins has been suggested as a therapeutic for lowering pathological diastolic stiffness levels. However, how increasing titin compliance impacts global cardiac function requires in-depth study. We investigate the effect of upregulating compliant titins in a novel mouse model with a genetically altered titin splicing factor; integrative approaches were used from intact cardiomyocyte mechanics to pressure-volume analysis and Doppler echocardiography. Methods and Results—: Compliant titins were upregulated through deletion of the RNA Recognition Motif of the splicing factor RBM20 ( Rbm20 ΔRRM mice). A genome-wide exon expression analysis and a candidate approach revealed that the phenotype is likely to be dominated by greatly increased lengths of titin’s spring elements. At both cardiomyocyte and left ventricular chamber levels, diastolic stiffness was reduced in heterozygous (+/−) Rbm20 ΔRRM mice with a further reduction in homozygous (−/−) mice at only the intact myocyte level. Fibrosis was present in only −/− Rbm20 ΔRRM hearts. The Frank-Starling Mechanism was reduced in a graded fashion in Rbm20 ΔRRM mice, at both the cardiomyocyte and left ventricular chamber levels. Exercise tests revealed an increase in exercise capacity in +/− mice. Conclusions—: Titin is not only important in diastolic but also in systolic cardiac function. Upregulating compliant titins reduces diastolic chamber stiffness owing to the increased compliance of myocytes, but it depresses end-systolic elastance; under conditions of exercise, the beneficial effects on diastolic function dominate. Therapeutic manipulation of the RBM20-based splicing system might be able to minimize effects on fibrosis and systolic function while improving the diastolic function in patients with heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.005610

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Methawasin, M., Hutchinson, K. R., Lee, E.-J., Smith, J. E., Saripalli, C., Hidalgo, C. G., Ottenheijm, C. A. C., & Granzier, H.
Venue
Circulation
Published
2014-05-13
Volume
129
Issue
19
Pages
1924-1936
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1981316465
Cited by
143
References
3
FWCI
9.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.