Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator Implants: Results From the National Cardiovascular Data Registry

Prutkin, Jordan M., Reynolds, Matthew R., Bao, Haikun, Curtis, Jeptha P., Al-Khatib, Sana M., Aggarwal, Saurabh, Uslan, Daniel Z. · 2014 · Circulation

Abstract

Background—: The rate of implantable cardioverter-defibrillator (ICD) infections has been increasing faster than that of implantation. We sought to determine the rate and predictors of ICD infection in a large cohort of Medicare patients. Methods and Results—: Cases submitted to the ICD Registry from 2006 to 2009 were matched to Medicare fee-for-service claims data using indirect patient identifiers. ICD infections occurring within 6 months of hospital discharge after implantation were identified by ICD-9 codes. Logistic regression was used to examine factors associated with risk of ICD infection. Of 200 909 implants, 3390 patients (1.7%) developed an ICD infection. The infection rate was 1.4%, 1.5%, and 2.0% for single, dual, and biventricular ICDs, respectively ( P <0.001). Generator replacement had a higher rate compared with initial implant (1.9% versus 1.6%, P <0.001). The factors associated with infection were adverse event during implant requiring reintervention (odds ratio [OR], 2.692; 95% confidence interval [CI], 2.304–3.145), previous valvular surgery (OR, 1.525; 95% CI, 1.375–1.692), reimplantation for device upgrade, malfunction, or manufacturer advisory (OR, 1.354; 95% CI, 1.196–1.533), renal failure on dialysis (OR, 1.342; 95% CI, 1.123–1.604), chronic lung disease (OR, 1.215; 95% CI, 1.125–1.312), cerebrovascular disease (OR, 1.172; 95% CI, 1.076–1.276), and warfarin (OR, 1.155; 95% CI, 1.060–1.257). Conclusions—: Patients who developed an ICD infection were more likely to have had peri-ICD implant complications requiring early reintervention, previous valve surgery, device replacement for reasons other than battery depletion, and increased comorbidity burden. Efforts should be made to carefully consider when to reenter the pocket at any time other than battery replacement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.114.009081

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 199

Metadata

Authors
Prutkin, J. M., Reynolds, M. R., Bao, H., Curtis, J. P., Al-Khatib, S. M., Aggarwal, S., & Uslan, D. Z.
Venue
Circulation
Published
2014-09-23
Volume
130
Issue
13
Pages
1037-1043
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2886588233
Cited by
199
References
1
FWCI
13.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator Implants: Results From the National Cardiovascular Data Registry. https://app.cochat.ai/papers/10.1161/circulationaha.114.009081
The paper
Prutkin, J. M., Reynolds, M. R., Bao, H., Curtis, J. P., Al-Khatib, S. M., Aggarwal, S., & Uslan, D. Z. (2014). Rates of and Factors Associated With Infection in 200 909 Medicare Implantable Cardioverter-Defibrillator Implants: Results From the National Cardiovascular Data Registry. Circulation. https://doi.org/10.1161/circulationaha.114.009081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.