Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Left Ventricular Ejection Fraction Normalization in Cardiac Resynchronization Therapy and Risk of Ventricular Arrhythmias and Clinical Outcomes: Results From the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT–CRT) Trial

Ruwald, Martin H., Solomon, Scott D., Foster, Elyse, Kutyifa, Valentina, Ruwald, Anne-Christine, Sherazi, Saadia, McNitt, Scott, Jons, Christian, Moss, Arthur J., Zareba, Wojciech·2014·Circulation

Abstract

Background—: Appropriate guideline criteria for use of implantable cardioverter-defibrillators (ICDs) do not take into account potential recovery of left ventricular ejection fraction (LVEF) in patients treated with CRT-defibrillator. Methods and Results—: Patients randomized to CRT-defibrillator from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) trial who survived and had paired echocardiograms at enrollment and at 12 months (n=752) were included. Patients were evaluated by LVEF recovery in 3 groups (LVEF ≤35% [reference], 36%–50%, and >50%) on outcomes of ventricular tachyarrhythmias (VTAs), VTA ≥200 bpm, ICD shock, heart failure or death, and inappropriate ICD therapy by multivariable Cox models. A total of 7.3% achieved LVEF normalization (>50%). The average follow-up was 2.2±0.8 years. The risk of VTA was reduced in patients with LVEF >50% (hazard ratio [HR], 0.24; 95% confidence interval [CI], 0.07–0.82; P =0.023) and LVEF of 36% to 50% (HR, 0.44; 95% CI, 0.28–0.68; P <0.001). Among patients with LVEF >50%, only 1 patient had VTA ≥200 bpm (HR, 0.16; 95% CI, 0.02–1.51), none were shocked by the ICD, and 2 died of nonarrhythmic causes. The risk of HF or death was reduced with improvements in LVEF (LVEF >50%: HR, 0.29; 95% CI, 0.09–0.97; P =0.045; and LVEF of 36%–50%: HR, 0.44; 95% CI, 0.28–0.69; P <0.001). For inappropriate ICD therapy, no additional risk reduction for LVEF>50% was seen compared with an LVEF of 36% to 50%. A total of 6 factors were associated with LVEF normalization, and patients with all factors present (n=42) did not experience VTAs (positive predictive value, 100%). Conclusions—: Patients who achieve LVEF normalization (>50%) have very low absolute and relative risk of VTAs and a favorable clinical course within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00180271.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.114.011283

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 189

Metadata

Authors
Ruwald, M. H., Solomon, S. D., Foster, E., Kutyifa, V., Ruwald, A.-C., Sherazi, S., McNitt, S., Jons, C., Moss, A. J., & Zareba, W.
Venue
Circulation
Published
2014-12
Volume
130
Issue
25
Pages
2278-2286
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2885859601
Cited by
189
References
5
FWCI
16.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular Ejection Fraction Normalization in Cardiac Resynchronization Therapy and Risk of Ventricular Arrhythmias and Clinical Outcomes: Results From the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT–CRT) Trial. https://app.cochat.ai/papers/10.1161/circulationaha.114.011283
The paper
Ruwald, M. H., Solomon, S. D., Foster, E., Kutyifa, V., Ruwald, A.-C., Sherazi, S., McNitt, S., Jons, C., Moss, A. J., & Zareba, W. (2014). Left Ventricular Ejection Fraction Normalization in Cardiac Resynchronization Therapy and Risk of Ventricular Arrhythmias and Clinical Outcomes: Results From the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT–CRT) Trial. Circulation. https://doi.org/10.1161/circulationaha.114.011283

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.