Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Simultaneous Biatrial High-Density (510–512 Electrodes) Epicardial Mapping of Persistent and Long-Standing Persistent Atrial Fibrillation in Patients: New Insights Into the Mechanism of Its Maintenance

Open access
Lee, Seungyup, Sahadevan, Jayakumar, Khrestian, Celeen M., Cakulev, Ivan, Markowitz, Alan, Waldo, Albert L. · 2015 · Circulation

Abstract

Background—: The mechanism(s) of persistent and long-standing persistent (LSP) atrial fibrillation (AF) is/are poorly understood. We performed high-density, simultaneous, biatrial, epicardial mapping of persistent and LSP AF in patients undergoing open heart surgery (1) to test the hypothesis that persistent and LSP AF are due to ≥1 drivers, either focal or reentrant, and (2) to characterize associated atrial activation. Methods and Results—: Twelve patients with persistent and LSP AF (1 month to 9 years duration) were studied at open heart surgery. During AF, electrograms were recorded from both atria simultaneously for 1 to 5 minutes from 510 to 512 epicardial electrodes with ECG lead II. Thirty-two consecutive seconds of activation sequence maps were produced per patient. During AF, multiple foci (QS unipolar atrial electrograms) of different cycle lengths (mean, 175±18 ms) were present in both atria in 11 of 12 patients. Foci (2–4 per patient, duration 5–32 s) were either sustained or intermittent, were predominantly found in the lateral left atrial free wall, and likely acted as drivers. Random and nonrandom breakthrough activation sites (initial r or R in unipolar atrial electrograms) were also found. In 1 of 12 patients, only breakthrough sites were found. All wave fronts emanated from foci and breakthrough sites, and largely either collided or merged with each other at variable sites. Repetitive focal QS activation occasionally generated repetitive wannabe reentrant activation in 5 of 12 patients. No actual reentry was found. Conclusions—: During persistent and LSP AF in 12 patients, wave fronts emanating from foci and breakthrough sites maintained AF. No reentry was demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.115.017007

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 161

Metadata

Authors
Lee, S., Sahadevan, J., Khrestian, C. M., Cakulev, I., Markowitz, A., & Waldo, A. L.
Venue
Circulation
Published
2015-12
Volume
132
Issue
22
Pages
2108-2117
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2220948299
Cited by
161
References
2
FWCI
15.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.