Application of Large-Scale Aptamer-Based Proteomic Profiling to Planned Myocardial Infarctions
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Emerging proteomic technologies using novel affinity-based reagents allow for efficient multiplexing with high-sample throughput. To identify early biomarkers of myocardial injury, we recently applied an aptamer-based proteomic profiling platform that measures 1129 proteins to samples from patients undergoing septal alcohol ablation for hypertrophic cardiomyopathy, a human model of planned myocardial injury. Here, we examined the scalability of this approach using a markedly expanded platform to study a far broader range of human proteins in the context of myocardial injury. Methods: We applied a highly multiplexed, expanded proteomic technique that uses single-stranded DNA aptamers to assay 4783 human proteins (4137 distinct human gene targets) to derivation and validation cohorts of planned myocardial injury, individuals with spontaneous myocardial infarction, and at-risk controls. Results: We found 376 target proteins that significantly changed in the blood after planned myocardial injury in a derivation cohort (n=20; P <1.05E-05, 1-way repeated measures analysis of variance, Bonferroni threshold). Two hundred forty-seven of these proteins were validated in an independent planned myocardial injury cohort (n=15; P <1.33E-04, 1-way repeated measures analysis of variance); >90% were directionally consistent and reached nominal significance in the validation cohort. Among the validated proteins that were increased within 1 hour after planned myocardial injury, 29 were also elevated in patients with spontaneous myocardial infarction (n=63; P <6.17E-04). Many of the novel markers identified in our study are intracellular proteins not previously identified in the peripheral circulation or have functional roles relevant to myocardial injury. For example, the cardiac LIM protein, cysteine- and glycine-rich protein 3, is thought to mediate cardiac mechanotransduction and stress responses, whereas the mitochondrial ATP synthase F 0 subunit component is a vasoactive peptide on its release from cells. Last, we performed aptamer-affinity enrichment coupled with mass spectrometry to technically verify aptamer specificity for a subset of the new biomarkers. Conclusions: Our results demonstrate the feasibility of large-scale aptamer multiplexing at a level that has not previously been reported and with sample throughput that greatly exceeds other existing proteomic methods. The expanded aptamer-based proteomic platform provides a unique opportunity for biomarker and pathway discovery after myocardial injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metabolic signatures of exercise in human plasma
Lewis, G. D., Farrell, L., Wood, M. J., Martinovic, M., Arany, Z., Rowe, G. C., Souza, A., Cheng, S., McCabe, E. L., Yang, E., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001006 · Cited by 432
Self-citation
Cited by
Systems biology in cardiovascular disease: a multiomics approach
Joshi, A., Rienks, M., Theofilatos, K., & Mayr, M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00477-1 · Cited by 301
Katz, D. H., Robbins, J. M., Deng, S., Tahir, U. A., Bick, A. G., Pampana, A., Yu, Z., Ngo, D., Benson, M. D., Chen, Z.-Z., et al. (2022) · Science Advances · doi:10.1126/sciadv.abm5164 · Cited by 206
“Aptamer-based protein measurements are more consistent over repeated measures, whether examining intra-assay or inter-assay CVs, consistent with previous work (1, 4, 35, 36).”
ResultSelf-citationComparison of Proteomic Assessment Methods in Multiple Cohort Studies
Raffield, L. M., Dang, H., Pratte, K. A., Jacobson, S., Gillenwater, L. A., Ampleford, E., Barjaktarevic, I., Basta, P., Clish, C. B., Comellas, A. P., et al. (2020) · PROTEOMICS · doi:10.1002/pmic.201900278 · Cited by 184
Self-citationCorey, K. E., Pitts, R., Lai, M., Loureiro, J., Masia, R., Osganian, S. A., Gustafson, J. L., Hutter, M. M., Gee, D. W., Meireles, O. R., et al. (2022) · Journal of Hepatology · doi:10.1016/j.jhep.2021.09.026 · Cited by 88
Self-citationSARZYNSKI, M. A., RICE, T. K., DESPRÉS, J.-P., PÉRUSSE, L., TREMBLAY, A., STANFORTH, P. R., TCHERNOF, A., BARBER, J. L., FALCIANI, F., CLISH, C., et al. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002859 · Cited by 62
Self-citation
Metadata
- Authors
- Jacob, J., Ngo, D., Finkel, N., Pitts, R., Gleim, S., Benson, M. D., Keyes, M. J., Farrell, L. A., Morgan, T., Jennings, L. L., & Gerszten, R. E.
- Venue
- Circulation
- Published
- 2018-03-20
- Volume
- 137
- Issue
- 12
- Pages
- 1270-1277
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2772003011
- Cited by
- 52
- References
- 1
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Large-Scale Aptamer-Based Proteomic Profiling to Planned Myocardial Infarctions. https://app.cochat.ai/papers/10.1161/circulationaha.117.029443
- The paper
- Jacob, J., Ngo, D., Finkel, N., Pitts, R., Gleim, S., Benson, M. D., Keyes, M. J., Farrell, L. A., Morgan, T., Jennings, L. L., & Gerszten, R. E. (2018). Application of Large-Scale Aptamer-Based Proteomic Profiling to Planned Myocardial Infarctions. Circulation. https://doi.org/10.1161/circulationaha.117.029443
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.