CoChat

High-Target Versus Low-Target Blood Pressure Management During Cardiopulmonary Bypass to Prevent Cerebral Injury in Cardiac Surgery Patients: A Randomized Controlled Trial

Vedel, Anne G., Holmgaard, Frederik, Rasmussen, Lars S., Langkilde, Annika, Paulson, Olaf B., Lange, Theis, Thomsen, Carsten, Olsen, Peter Skov, Ravn, Hanne Berg, Nilsson, Jens C. · 2018 · Circulation
Cited by 189

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Background: Cerebral injury is an important complication after cardiac surgery with the use of cardiopulmonary bypass. The rate of overt stroke after cardiac surgery is 1% to 2%, whereas silent strokes, detected by diffusion-weighted magnetic resonance imaging, are found in up to 50% of patients. It is unclear whether a higher versus a lower blood pressure during cardiopulmonary bypass reduces cerebral infarction in these patients. Methods: In a patient- and assessor-blinded randomized trial, we allocated patients to a higher (70–80 mm Hg) or lower (40–50 mm Hg) target for mean arterial pressure by the titration of norepinephrine during cardiopulmonary bypass. Pump flow was fixed at 2.4 L·min −1 ·m −2 . The primary outcome was the total volume of new ischemic cerebral lesions (summed in millimeters cubed), expressed as the difference between diffusion-weighted imaging conducted preoperatively and again postoperatively between days 3 and 6. Secondary outcomes included diffusion-weighted imaging–evaluated total number of new ischemic lesions. Results: Among the 197 enrolled patients, mean (SD) age was 65.0 (10.7) years in the low-target group (n=99) and 69.4 (8.9) years in the high-target group (n=98). Procedural risk scores were comparable between groups. Overall, diffusion-weighted imaging revealed new cerebral lesions in 52.8% of patients in the low-target group versus 55.7% in the high-target group ( P =0.76). The primary outcome of volume of new cerebral lesions was comparable between groups, 25 mm 3 (interquartile range, 0–118 mm 3 ; range, 0–25 261 mm 3 ) in the low-target group versus 29 mm 3 (interquartile range, 0–143 mm 3 ; range, 0–22 116 mm 3 ) in the high-target group (median difference estimate, 0; 95% confidence interval, −25 to 0.028; P =0.99), as was the secondary outcome of number of new lesions (1 [interquartile range, 0–2; range, 0–24] versus 1 [interquartile range, 0–2; range, 0–29] respectively; median difference estimate, 0; 95% confidence interval, 0–0; P =0.71). No significant difference was observed in frequency of severe adverse events. Conclusions: Among patients undergoing on-pump cardiac surgery, targeting a higher versus a lower mean arterial pressure during cardiopulmonary bypass did not seem to affect the volume or number of new cerebral infarcts. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02185885.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.117.030308

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
Vedel, A. G., Holmgaard, F., Rasmussen, L. S., Langkilde, A., Paulson, O. B., Lange, T., Thomsen, C., Olsen, P. S., Ravn, H. B., & Nilsson, J. C.
Venue
Circulation
Published
2018-04-24
Volume
137
Issue
17
Pages
1770-1780
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2783516228
Cited by
189
References
31
FWCI
20.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.