The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study
Abstract
Background: Asymptomatic atrial fibrillation (AF) is increasingly common in the aging population and implicated in many ischemic strokes. Earlier identification of AF with appropriate anticoagulation may decrease stroke morbidity and mortality. Methods: We conducted a randomized controlled trial of AF screening using an AliveCor Kardia monitor attached to a WiFi-enabled iPod to obtain ECGs (iECGs) in ambulatory patients. Patients ≥65 years of age with a CHADS-VASc score ≥2 free from AF were randomized to the iECG arm or routine care (RC). iECG participants acquired iECGs twice weekly over 12 months (plus additional iECGs if symptomatic) onto a secure study server with overread by an automated AF detection algorithm and by a cardiac physiologist and/or consultant cardiologist. Time to diagnosis of AF was the primary outcome measure. The overall cost of the devices, ECG interpretation, and patient management were captured and used to generate the cost per AF diagnosis in iECG patients. Clinical events and patient attitudes/experience were also evaluated. Results: We studied 1001 patients (500 iECG, 501 RC) who were 72.6±5.4 years of age; 534 were female. Mean CHADS-VASc score was 3.0 (heart failure, 1.4%; hypertension, 54%; diabetes mellitus, 30%; prior stroke/transient ischemic attack, 6.5%; arterial disease, 15.9%; all CHADS-VASc risk factors were evenly distributed between groups). Nineteen patients in the iECG group were diagnosed with AF over the 12-month study period versus 5 in the RC arm (hazard ratio, 3.9; 95% confidence interval=1.4–10.4; P =0.007) at a cost per AF diagnosis of $10 780 (£8255). There was a similar number of stroke/transient ischemic attack/systemic embolic events (6 versus 10, iECG versus RC; hazard ratio=0.61; 95% confidence interval=0.22–1.69; P =0.34). The majority of iECG patients were satisfied with the device, finding it easy to use without restricting activities or causing anxiety. Conclusions: Screening with twice-weekly single-lead iECG with remote interpretation in ambulatory patients ≥65 years of age at increased risk of stroke is significantly more likely to identify incident AF than RC over a 12-month period. This approach is also highly acceptable to this group of patients, supporting further evaluation in an appropriately powered, event-driven clinical trial. Clinical Trial Registration: URL: https://www.isrctn.com . Unique identifier: ISRCTN10709813.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although such systems can support various types of biophysical measurements of physiological health (8–13), additional advances are needed to meet the challenging requirements of the NICU, where comprehensive, continuous sensing with wireless functionality, clinical-grade measurement fidelity, and mechanical form factors that eliminate risk of harm to exceptionally fragile neonatal skin are essent”
From Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care (2019) · cites this paper as [12]
The cited source says what the claim attributes to it.
In the citing paper
“The recent REHEARSE-AF study (19) showed that remote ECG monitoring with Kardia in ambulatory patients is more likely to identify atrial fibrillation than routine care.”
From Artificial Intelligence in Medicine: Today and Tomorrow (2020) · cites this paper as [19]
In the citing paper
“Whilst AliveCor has now undergone assessment against conventional care for AF detection [25], it has yet to be assessed against standard care for the broader investigation of palpitations and arrhythmia assessment.”
From Multi-centre Randomised Controlled Trial of a Smartphone-based Event Recorder Alongside Standard Care Versus Standard Care for Patients Presenting to the Emergency Department with Palpitations and Pre-syncope: The IPED (Investigation of Palpitations in the ED) study (2019) · cites this paper as [25]
In the citing paper
“A recent trial comparing AliveCor’s technology with routine care (n = 1001) resulted in a nearly fourfold increase in atrial fibrillation diagnosis [15].”
From Wearables and the Medical Revolution (2018) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Kirchhof, P. F., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Gelder, I. C. V., Al‐Attar, N., Hindricks, G., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,924
Ruff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Risk Factors for Stroke and Efficacy of Antithrombotic Therapy in Atrial Fibrillation
(1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.13.1449 · Cited by 2,602
Power and sample size calculations
Dupont, W. D., & Plummer, W. D. (1990) · Controlled Clinical Trials · doi:10.1016/0197-2456(90)90005-m · Cited by 2,112
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 1×
“Vascular disease, n (%) 71 (14) 79 (16) 0.”
Stroke Severity in Atrial Fibrillation
Lin, H., Wolf, P. A., Kelly‐Hayes, M., Beiser, A., Kase, C. S., Benjamin, E. J., & D’Agostino, R. B. (1996) · Stroke · doi:10.1161/01.str.27.10.1760 · Cited by 1,412
Flagged first, then by citations
1 of the 44 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- 10.1001/archinte.1994.00420130036007 · DOI
Cited by
Sorted by citations
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
Gelder, I. C. V., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., Potter, T. J. R. D., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,594
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744
January, C. T., Wann, L. S., Calkins, H. G., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.011 · Cited by 2,252
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Metadata
- Authors
- Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B.
- Affiliations
- Morriston Hospital (GB)
- From Swansea University Medical School, UK (J.P.J.H., K.W., M.B.G.); Swansea University College of Health and Human Sciences, UK (C.P., A.C.); Princess of Wales Hospital, Cardiology, Bridgend, UK (M.G.); and Regional Cardiac Centre, Morriston Hospital, Swansea, UK (J.P.B.).
- Venue
- Circulation
- Published
- 2017-11-07
- Volume
- 136
- Issue
- 19
- Pages
- 1784-1794
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2752766789
- Cited by
- 580
- References
- 44
- Citations by year
- 2026: 31 · 2025: 53 · 2024: 60 · 2023: 67 · 2022: 67 · 2021: 96 · 2020: 76 · 2019: 72 · 2018: 52 · 2017: 6
- FWCI
- 43.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, stroke prevention, systemic embolism, patient satisfaction, older adults, anticoagulation, ischemic stroke risk stratification
- MeSH terms
- Action Potentials, Aged, Algorithms, Atrial Fibrillation, Cost-Benefit Analysis, Equipment Design, Female, Heart Conduction System, Heart Rate, Humans, Male, Predictive Value of Tests, Prognosis, Prospective Studies, Signal Processing, Computer-Assisted, Telemetry, Time Factors, Wales, Reproducibility of Results, Electrocardiography, Ambulatory, Health Care Costs, Telemedicine, Computers, Handheld, Asymptomatic Diseases, Remote Sensing Technology, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review