Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Determination and Interpretation of the QT Interval: Comprehensive Analysis of a Large Cohort of Long QT Syndrome Patients and Controls

Open access
Vink, Arja Suzanne, Neumann, Benjamin, Lieve, Krystien V.V., Sinner, Moritz F., Hofman, Nynke, el Kadi, Soufiane, Schoenmaker, Melissa H.A., Slaghekke, Hanneke M.J., de Jong, Jonas S.S.G., Clur, Sally-Ann B., Blom, Nico A., Kääb, Stefan, Wilde, Arthur A.M., Postema, Pieter G. · 2018 · Circulation

Abstract

Background: Long QT syndrome (LQTS) is associated with potentially fatal arrhythmias. Treatment is very effective, but its diagnosis may be challenging. Importantly, different methods are used to assess the QT interval, which makes its recognition difficult. QT experts advocate manual measurements with the tangent or threshold method. However, differences between these methods and their performance in LQTS diagnosis have not been established. We aimed to assess similarities and differences between these 2 methods for QT interval analysis to aid in accurate QT assessment for LQTS. Methods: Patients with a confirmed pathogenic variant in KCNQ1 (LQT1), KCNH2 (LQT2), or SCN5A (LQT3) genes and their family members were included. Genotype-positive patients were identified as LQTS cases and genotype-negative family members as controls. ECGs were analyzed with both methods, providing inter- and intrareader validity and diagnostic accuracy. Cutoff values based on control population’s 95th and 99th percentiles, and LQTS-patients’ 1st and 5th percentiles were established based on the method to correct for heart rate, age, and sex. Results: We included 1484 individuals from 265 families, aged 33±21 years and 55% females. In the total cohort, QT Tangent was 10.4 ms shorter compared with QT Threshold (95% limits of agreement±20.5 ms, P <0.0001). For all genotypes, QT Tangent was shorter than QT Threshold ( P <0.0001), but this was less pronounced in LQT2. Both methods yielded a high inter- and intrareader validity (intraclass correlation coefficient >0.96), and a high diagnostic accuracy (area under the curve >0.84). Using the current guideline cutoff (QTc interval 480 ms), both methods had similar specificity but yielded a different sensitivity. QTc interval cutoff values of QT Tangent were lower compared with QT Threshold and different depending on the correction for heart rate, age, and sex. Conclusion: The QT interval varies depending on the method used for its assessment, yet both methods have a high validity and can both be used in diagnosing LQTS. However, for diagnostic purposes current guideline cutoff values yield different results for these 2 methods and could result in inappropriate reassurance or treatment. Adjusted cutoff values are therefore specified for method, correction formula, age, and sex. In addition, a freely accessible online probability calculator for LQTS ( www.QTcalculator.org ) has been made available as an aid in the interpretation of the QT interval.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.033943

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Metadata

Authors
Vink, A. S., Neumann, B., Lieve, K. V. V., Sinner, M. F., Hofman, N., el Kadi, S., Schoenmaker, M. H. A., Slaghekke, H. M. J., de Jong, J. S. S. G., Clur, S.-A. B., Blom, N. A., Kääb, S., Wilde, A. A. M., & Postema, P. G.
Venue
Circulation
Published
2018-11-20
Volume
138
Issue
21
Pages
2345-2358
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2903385841
Cited by
176
References
5
FWCI
10.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination and Interpretation of the QT Interval: Comprehensive Analysis of a Large Cohort of Long QT Syndrome Patients and Controls. https://app.cochat.ai/papers/10.1161/circulationaha.118.033943
The paper
Vink, A. S., Neumann, B., Lieve, K. V. V., Sinner, M. F., Hofman, N., el Kadi, S., Schoenmaker, M. H. A., Slaghekke, H. M. J., de Jong, J. S. S. G., Clur, S.-A. B., Blom, N. A., Kääb, S., Wilde, A. A. M., & Postema, P. G. (2018). Determination and Interpretation of the QT Interval: Comprehensive Analysis of a Large Cohort of Long QT Syndrome Patients and Controls. Circulation. https://doi.org/10.1161/circulationaha.118.033943

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.