Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Improving the Diagnostic Performance of 18 F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in Prosthetic Heart Valve Endocarditis

Open access
Swart, Laurens E., Gomes, Anna, Scholtens, Asbjørn M., Sinha, Bhanu, Tanis, Wilco, Lam, Marnix G.E.H., van der Vlugt, Maureen J., Streukens, Sebastian A.F., Aarntzen, Erik H.J.G., Bucerius, Jan, van Assen, Sander, Bleeker-Rovers, Chantal P., van Geel, Peter Paul, Krestin, Gabriel P., van Melle, Joost P., Roos-Hesselink, Jolien W., Slart, Riemer H.J.A., Glaudemans, Andor W.J.M., Budde, Ricardo P.J.·2018·Circulation

Abstract

Background: 18 F-Fluorodeoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) was recently introduced as a new tool for the diagnosis of prosthetic heart valve endocarditis (PVE). Previous studies reporting a modest diagnostic accuracy may have been hampered by unstandardized image acquisition and assessment, and several confounders, as well. The aim of this study was to improve the diagnostic performance of FDG PET/CT in patients in whom PVE was suspected by identifying and excluding possible confounders, using both visual and standardized quantitative assessments. Methods: In this multicenter study, 160 patients with a prosthetic heart valve (median age, 62 years [43–73]; 68% male; 82 mechanical valves; 62 biological; 9 transcatheter aortic valve replacements; 7 other) who underwent FDG PET/CT for suspicion of PVE, and 77 patients with a PV (median age, 73 years [65–77]; 71% male; 26 mechanical valves; 45 biological; 6 transcatheter aortic valve replacements) who underwent FDG PET/CT for other indications (negative control group), were retrospectively included. Their scans were reassessed by 2 independent observers blinded to all clinical data, both visually and quantitatively on available European Association of Nuclear Medicine Research Ltd–standardized reconstructions. Confounders were identified by use of a logistic regression model and subsequently excluded. Results: Visual assessment of FDG PET/CT had a sensitivity/specificity/positive predictive value/negative predictive value for PVE of 74%/91%/89%/78%, respectively. Low inflammatory activity (C-reactive protein <40 mg/L) at the time of imaging and use of surgical adhesives during prosthetic heart valve implantation were significant confounders, whereas recent valve implantation was not. After the exclusion of patients with significant confounders, diagnostic performance values of the visual assessment increased to 91%/95%/95%/91%. As a semiquantitative measure of FDG uptake, a European Association of Nuclear Medicine Research Ltd–standardized uptake value ratio of ≥2.0 was a 100% sensitive and 91% specific predictor of PVE. Conclusions: Both visual and quantitative assessments of FDG PET/CT have a high diagnostic accuracy in patients in whom PVE is suspected. FDG PET/CT should be implemented early in the diagnostic workup to prevent the negative confounding effects of low inflammatory activity (eg, attributable to prolonged antibiotic therapy). Recent valve implantation was not a significant predictor of false-positive interpretations, but surgical adhesives used during implantation were.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.035032

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 196

Metadata

Authors
Swart, L. E., Gomes, A., Scholtens, A. M., Sinha, B., Tanis, W., Lam, M. G. E. H., van der Vlugt, M. J., Streukens, S. A. F., Aarntzen, E. H. J. G., Bucerius, J., van Assen, S., Bleeker-Rovers, C. P., van Geel, P. P., Krestin, G. P., van Melle, J. P., Roos-Hesselink, J. W., Slart, R. H. J. A., Glaudemans, A. W. J. M., & Budde, R. P. J.
Venue
Circulation
Published
2018-10-02
Volume
138
Issue
14
Pages
1412-1427
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2898219870
Cited by
196
References
3
FWCI
16.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving the Diagnostic Performance of 18 F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in Prosthetic Heart Valve Endocarditis. https://app.cochat.ai/papers/10.1161/circulationaha.118.035032
The paper
Swart, L. E., Gomes, A., Scholtens, A. M., Sinha, B., Tanis, W., Lam, M. G. E. H., van der Vlugt, M. J., Streukens, S. A. F., Aarntzen, E. H. J. G., Bucerius, J., van Assen, S., Bleeker-Rovers, C. P., van Geel, P. P., Krestin, G. P., van Melle, J. P., Roos-Hesselink, J. W., Slart, R. H. J. A., Glaudemans, A. W. J. M., & Budde, R. P. J. (2018). Improving the Diagnostic Performance of 18 F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in Prosthetic Heart Valve Endocarditis. Circulation. https://doi.org/10.1161/circulationaha.118.035032

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.