The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Device-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes
Open accessAbstract
Background: In patients with atrial fibrillation, left atrial appendage closure with the Watchman device prevents thromboembolism from the left atrial appendage; however, thrombus may form on the left atrial face of the device, and then potentially embolize. Herein, we studied the incidence, predictors, and clinical outcome of device-related thrombus (DRT) using a large series of clinical trial cohorts of patients undergoing Watchman implantation. Methods: We studied the device arms of 4 prospective Food and Drug Administration trials: PROTECT-AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (n=463); PREVAIL (Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) (n=269); CAP (Continued Access to PROTECT AF registry) (n=566); and CAP2 (Continued Access to PREVAIL registry) (n=578). Surveillance transesophageal echocardiographs were performed at 45 days and 12 months in all patients, and also at 6 months in the randomized control trials. We assessed both the incidence of DRT during these transesophageal echocardiographs (and other unscheduled transesophageal echocardiographs), and clinical outcomes of postprocedure stroke or systemic embolism (SSE) and adjusted for CHA 2 DS 2 -VASC and HAS-BLED scores. Results: Of 1739 patients who received an implant (7159 patient-years follow-up; CHA 2 DS 2 -VASc=4.0), DRT was seen in 65 patients (3.74%). The rates of SSE with and without DRT were 7.46 and 1.78 per 100 patient-years (adjusted rate ratio, 3.55; 95% confidence interval [CI], 2.18–5.79; P <0.001), and ischemic SSE rates were 6.28 and 1.65 per 100 patient-years (adjusted rate ratio, 3.22; 95% CI, 1.90–5.45, P <0.001). On multivariable modeling analysis, the predictors of DRT were as follows: history of transient ischemic attack or stroke (odds ratio [OR], 2.31; 95% CI, 1.26–4.25; P =0.007), permanent atrial fibrillation (OR, 2.24; 95% CI, 1.19–4.20; P =0.012); vascular disease (OR, 2.06; 95% CI, 1.08–3.91; P =0.028); left atrial appendage diameter (OR, 1.06 per mm increase; 95% CI, 1.01–1.12; P =0.019); left ventricular ejection fraction (OR, 0.96 per 1% increase; 95% CI, 0.94–0.99; P =0.009). DRT and SSE both occurred in 17 of 65 patients (26.2%). Of the 19 SSE events in these patients with DRT, 9 of 19 (47.4%) and 12 of 19 (63.2%) occurred within 1 and 6 months of DRT detection. Conversely, after left atrial appendage closure, most SSEs (123/142, 86.62%) occurred in patients without DRT. Conclusions: After left atrial appendage closure with Watchman, DRT (≈3.7%) is not frequent but, when present, is associated with a higher rate of stroke and systemic embolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holmes, D. R., Reddy, V. Y., Turi, Z. G., Doshi, S. K., Sievert, H., Buchbinder, M., Mullin, C. M., & Sick, P. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61343-x · Cited by 2,240
Self-citationHolmes, D. R., Kar, S., Price, M. J., Whisenant, B., Sievert, H., Doshi, S. K., Huber, K., & Reddy, V. Y. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.029 · Cited by 1,845
Self-citationFriberg, L., Rosenqvist, M., & Lip, G. Y. H. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr488 · Cited by 1,192
5-Year Outcomes After Left Atrial Appendage Closure
Reddy, V. Y., Doshi, S. K., Kar, S., Gibson, D. N., Price, M. J., Huber, K., Horton, R. P., Buchbinder, M., Neuzil, P., Gordon, N. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.021 · Cited by 1,032
Self-citationReddy, V. Y., Sievert, H., Halperin, J., Doshi, S. K., Buchbinder, M., Neuzil, P., Huber, K., Whisenant, B., Kar, S., Swarup, V., et al. (2014) · JAMA · doi:10.1001/jama.2014.15192 · Cited by 1,018
Self-citationReddy, V. Y., Holmes, D., Doshi, S. K., Neuzil, P., & Kar, S. (2011) · Circulation · doi:10.1161/circulationaha.110.976449 · Cited by 863
Self-citationReddy, V. Y., Doshi, S. K., Sievert, H., Buchbinder, M., Neuzil, P., Huber, K., Halperin, J. L., & Holmes, D. (2013) · Circulation · doi:10.1161/circulationaha.112.114389 · Cited by 677
Self-citationHolmes, D. R., Doshi, S. K., Kar, S., Price, M. J., Sanchez, J. M., Sievert, H., Valderrabano, M., & Reddy, V. Y. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.025 · Cited by 543
Self-citationBoersma, L. V., Ince, H., Kische, S., Pokushalov, E., Schmitz, T., Schmidt, B., Gori, T., Meincke, F., Protopopov, A. V., Betts, T., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.038 · Cited by 433
Lip, G., Lindhardsen, J., Lane, D., Ahlehoff, O., Hansen, M., Raunsø, J., Tolstrup, J., Hansen, P., Gislason, G., Torp-Pedersen, C., et al. (2011) · Thrombosis and Haemostasis · doi:10.1160/th11-05-0364 · Cited by 428
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Kar, S., Doshi, S. K., Sadhu, A., Horton, R., Osorio, J., Ellis, C., Stone, J., Shah, M., Dukkipati, S. R., Adler, S., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.050117 · Cited by 414
Self-citation
Metadata
- Authors
- Dukkipati, S. R., Kar, S., Holmes, D. R., Doshi, S. K., Swarup, V., Gibson, D. N., Maini, B., Gordon, N. T., Main, M. L., & Reddy, V. Y.
- Venue
- Circulation
- Published
- 2018-08-28
- Volume
- 138
- Issue
- 9
- Pages
- 874-885
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2802541056
- Cited by
- 451
- References
- 20
- FWCI
- 28.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Device-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes. https://app.cochat.ai/papers/10.1161/circulationaha.118.035090
- The paper
- Dukkipati, S. R., Kar, S., Holmes, D. R., Doshi, S. K., Swarup, V., Gibson, D. N., Maini, B., Gordon, N. T., Main, M. L., & Reddy, V. Y. (2018). Device-Related Thrombus After Left Atrial Appendage Closure: Incidence, Predictors, and Outcomes. Circulation. https://doi.org/10.1161/circulationaha.118.035090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.