Accuracy of Fractional Flow Reserve Derived From Coronary Angiography
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFR angio ) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFR angio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFR angio . Methods: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFR angio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFR angio for predicting pressure wire–derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. Results: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR≤0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFR angio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFR angio values correlated well with FFR measurements ( r =0.80, P <0.001) and the Bland–Altman 95% confidence limits were between −0.14 and 0.12. The device success rate for FFR angio was 99%. Conclusions: FFR angio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire–derived FFR. FFR angio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique Identifier: NCT03226262.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Self-citationFractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary Disease
De Bruyne, B., Pijls, N. H. J., Kalesan, B., Barbato, E., Tonino, P. A. L., Piroth, Z., Jagic, N., Möbius-Winkler, S., Rioufol, G., Witt, N., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1205361 · Cited by 2,772
Self-citationPercutaneous Coronary Intervention of Functionally Nonsignificant Stenosis
Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.087 · Cited by 1,516
Self-citationTu, S., Westra, J., Yang, J., von Birgelen, C., Ferrara, A., Pellicano, M., Nef, H., Tebaldi, M., Murasato, Y., Lansky, A., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.013 · Cited by 591
Morris, P. D., Ryan, D., Morton, A. C., Lycett, R., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.08.024 · Cited by 270
Validation Study of Image-Based Fractional Flow Reserve During Coronary Angiography
Pellicano, M., Lavi, I., Bruyne, B. D., Assa, H. V., Assali, A. R., Valtzer, O., Lotringer, Y., Weisz, G., Almagor, Y., Xaplanteris, P., et al. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.005259 · Cited by 119
Self-citationFast Virtual Fractional Flow Reserve Based Upon Steady-State Computational Fluid Dynamics Analysis
Morris, P., Soto, D. A. S., Feher, J., Rafiroiu, D., Lungu, A., Varma, S. D., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2017) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2017.04.003 · Cited by 112
Cited by
Impact of Artificial Intelligence on Interventional Cardiology
Sardar, P., Abbott, J. D., Kundu, A., Aronow, H. D., Granada, J. F., & Giri, J. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.04.048 · Cited by 151
Metadata
- Authors
- Fearon, W. F., Achenbach, S., Engstrom, T., Assali, A., Shlofmitz, R., Jeremias, A., Fournier, S., Kirtane, A. J., Kornowski, R., Greenberg, G., Jubeh, R., Kolansky, D. M., McAndrew, T., Dressler, O., Maehara, A., Matsumura, M., Leon, M. B., De Bruyne, B., & For the FAST-FFR Study Investigators
- Venue
- Circulation
- Published
- 2019-01-22
- Volume
- 139
- Issue
- 4
- Pages
- 477-484
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2890396820
- Cited by
- 239
- References
- 8
- FWCI
- 25.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. https://app.cochat.ai/papers/10.1161/circulationaha.118.037350
- The paper
- Fearon, W. F., Achenbach, S., Engstrom, T., Assali, A., Shlofmitz, R., Jeremias, A., Fournier, S., Kirtane, A. J., Kornowski, R., Greenberg, G., Jubeh, R., Kolansky, D. M., McAndrew, T., Dressler, O., Maehara, A., Matsumura, M., Leon, M. B., De Bruyne, B., & For the FAST-FFR Study Investigators. (2019). Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. Circulation. https://doi.org/10.1161/circulationaha.118.037350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.