Fearon, William F., Achenbach, Stephan, Engstrom, Thomas, Assali, Abid, Shlofmitz, Richard, Jeremias, Allen, Fournier, Stephane, Kirtane, Ajay J., Kornowski, Ran, Greenberg, Gabriel, Jubeh, Rami, Kolansky, Daniel M., McAndrew, Thomas, Dressler, Ovidiu, Maehara, Akiko, Matsumura, Mitsuaki, Leon, Martin B., De Bruyne, Bernard, For the FAST-FFR Study Investigators · 2019 · Circulation
Cited by 239

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFR angio ) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFR angio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFR angio . Methods: Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in ≥2 different projections, on-site operators blinded to FFR then calculated FFR angio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFR angio for predicting pressure wire–derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity. Results: Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR≤0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFR angio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFR angio values correlated well with FFR measurements ( r =0.80, P <0.001) and the Bland–Altman 95% confidence limits were between −0.14 and 0.12. The device success rate for FFR angio was 99%. Conclusions: FFR angio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire–derived FFR. FFR angio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique Identifier: NCT03226262.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.118.037350

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 239

Metadata

Authors
Fearon, W. F., Achenbach, S., Engstrom, T., Assali, A., Shlofmitz, R., Jeremias, A., Fournier, S., Kirtane, A. J., Kornowski, R., Greenberg, G., Jubeh, R., Kolansky, D. M., McAndrew, T., Dressler, O., Maehara, A., Matsumura, M., Leon, M. B., De Bruyne, B., & For the FAST-FFR Study Investigators
Venue
Circulation
Published
2019-01-22
Volume
139
Issue
4
Pages
477-484
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2890396820
Cited by
239
References
8
FWCI
25.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. https://app.cochat.ai/papers/10.1161/circulationaha.118.037350
The paper
Fearon, W. F., Achenbach, S., Engstrom, T., Assali, A., Shlofmitz, R., Jeremias, A., Fournier, S., Kirtane, A. J., Kornowski, R., Greenberg, G., Jubeh, R., Kolansky, D. M., McAndrew, T., Dressler, O., Maehara, A., Matsumura, M., Leon, M. B., De Bruyne, B., & For the FAST-FFR Study Investigators. (2019). Accuracy of Fractional Flow Reserve Derived From Coronary Angiography. Circulation. https://doi.org/10.1161/circulationaha.118.037350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.