Preventive or Deferred Ablation of Ventricular Tachycardia in Patients With Ischemic Cardiomyopathy and Implantable Defibrillator (BERLIN VT): A Multicenter Randomized Trial
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Catheter ablation for ventricular tachycardia (VT) reduces the recurrence of VT in patients with implantable cardioverter-defibrillators (ICDs). The appropriate timing of VT ablation and its effects on mortality and heart failure progression remain a matter of debate. In patients with life-threatening arrhythmias necessitating ICD implantation, we compared outcomes of preventive VT ablation (undertaken before ICD implantation to prevent ICD shocks for VT) and deferred ablation after 3 ICD shocks for VT. Methods: The BERLIN VT study (Preventive Ablation of Ventricular Tachycardia in Patients With Myocardial Infarction) was a prospective, open, parallel, randomized trial performed at 26 centers. Patients with stable ischemic cardiomyopathy, a left ventricular ejection fraction between 30% and 50%, and documented VT were randomly assigned 1:1 to a preventive or deferred ablation strategy. The primary outcome was a composite of all-cause death and unplanned hospitalization for either symptomatic ventricular arrhythmia or worsening heart failure. Secondary outcomes included sustained ventricular tachyarrhythmia and appropriate ICD therapy. We hypothesized that preventive ablation strategy would be superior to deferred ablation strategy in the intention-to-treat population. Results: During a mean follow-up of 396±284 days, the primary end point occurred in 25 (32.9%) of 76 patients in the preventive ablation group and 23 (27.7%) of 83 patients in the deferred ablation group (hazard ratio, 1.09 [95% CI, 0.62–1.92]; P =0.77). On the basis of prespecified criteria for interim analyses, the study was terminated early for futility. In the preventive versus deferred ablation group, 6 versus 2 patients died (7.9% versus 2.4%; P =0.18), 8 versus 2 patients were admitted for worsening heart failure (10.4% versus 2.3%; P =0.062), and 15 versus 21 patients were hospitalized for symptomatic ventricular arrhythmia (19.5% versus 25.3%; P =0.27). Among secondary outcomes, the proportions of patients with sustained ventricular tachyarrhythmia (39.7% versus 48.2%; P =0.050) and appropriate ICD therapy (34.2% versus 47.0%; P =0.020) were numerically reduced in the preventive ablation group. Conclusions: Preventive VT ablation before ICD implantation did not reduce mortality or hospitalization for arrhythmia or worsening heart failure during 1 year of follow-up compared with the deferred ablation strategy. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02501005.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citationProphylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · cited 1×
“Secondary outcome measures were (1) sustained VT or ventricular fibrillation (including episodes not detected by the ICD, eg, because of an arrhythmia cycle length outside the detection window); (2) appropriate ICD therapy; (3) inappropriate ICD therapy; (4) death resulting from any cause; (5) death resulting from car…”
MethodWilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Self-citation
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Self-citationMarijon, E., Narayanan, K., Smith, K., Barra, S., Basso, C., Blom, M. T., Crotti, L., D'Avila, A., Deo, R., Dumas, F., et al. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00875-9 · Cited by 313
Self-citation
Metadata
- Authors
- Willems, S., Tilz, R. R., Steven, D., Kääb, S., Wegscheider, K., Gellér, L., Meyer, C., Heeger, C.-H., Metzner, A., Sinner, M. F., Schlüter, M., Nordbeck, P., Eckardt, L., Bogossian, H., Sultan, A., Wenzel, B., Kuck, K.-H., Piorkowski, C., Lebedev, D., Kautzner, J., Sticherling, C., Deneke, T., Rostock, T., Ukena, C., Kuniss, M., Makimoto, H., Hindricks, G., Bänsch, D., Schreieck, J., Kolb, C., Geller, J., Pokushalov, E., Gutleben, K., Sommer, P., Boldt, L. H., & Parwani, A.
- Venue
- Circulation
- Published
- 2020-03-31
- Volume
- 141
- Issue
- 13
- Pages
- 1057-1067
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3003338322
- Cited by
- 190
- References
- 4
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.