Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-Up: The ALTITUDE Survival Study
Open accessAbstract
Background—: Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy–defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a network. Methods and Results—: Survival status in patients implanted with ICD and CRT devices across the United States from a single manufacturer was assessed. Outcomes were compared between patients followed in device clinic settings and those who regularly transmit remote data collected from the device an average of 4 times monthly. Shock delivery and electrogram analysis could be ascertained from patients followed on the network, enabling survival after ICD shock to be evaluated. One- and 5-year survival rates in 185 778 patients after ICD implantation were 92% and 68% and were 88% and 54% for CRT-D device recipients. In 8228 patients implanted with CRT-only devices, survival was 82% and 48% at 1 and 5 years, respectively. For the 69 556 ICD and CRT-D patients receiving remote follow-up on the network, 1- and 5-year survival rates were higher compared with those in the 116 222 patients who received device follow-up in device clinics only (50% reduction; P <0.0001). There were no differences between patients followed on or off the remote network for the characteristics of age, gender, implanted device year or type, and economic or educational status. Shock therapy was associated with subsequent mortality risk for both ICD and CRT-D recipients. Conclusions—: Survival after ICD and CRT-D implantation in patients treated in naturalistic practice compares favorably with survival rates observed in clinical trials. Remote follow-up of device data is associated with excellent survival, but arrhythmias that result in device therapy in this population are associated with a higher mortality risk compared with patients who do not require shock therapy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a contemporary real-world ICD population, appropriate shocks occur in approximately 6% per year of ICD patients, and inappropriate shocks occur in approximately 8% per year.
“In a contemporary real-world ICD population, appropriate shocks occur in ≈6% per year of ICD patients, and inappropriate shocks occur in ≈8% per year.24”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [24]
The section “Shock Therapies and Programming in Patients Followed Up on the Network” reports the one-year figures in the opposite order: 8% appropriate shocks and 6% inappropriate shocks. The citing sentence reverses those rates. (LLM, conf=0.95)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredIn the large but nonrandomized ALTITUDE study, the use of remote monitoring for ICD patients was associated with improved survival.
“In the large but nonrandomized ALTITUDE study, in which monitoring was continuous, the use of remote monitoring for ICD patients was associated with improved survival”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885 · see citing works
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552 · see citing works
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812 · see citing works
Self-citationACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546 · see citing works
Self-citationTutorial in biostatistics: competing risks and multi‐state models
Putter, H., Fiocco, M. F., & Geskus, R. B. (2006) · Statistics in Medicine · doi:10.1002/sim.2712 · Cited by 2,458 · see citing works
WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167586 · Cited by 2,251 · see citing works
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R., Marchlinski, F. E., Yee, R. K., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,458 · see citing works
Wilkoff, B. L., HESS, M., Young, J. B., & Abraham, W. T. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03625.x · Cited by 835 · see citing works
Cleland, J. G. F., Daubert, J., Erdmann, E., Freemantle, N., Gras, D., KAPPENBERGER, L. J., Tavazzi, L., & on behalf of The CARE-HF Study Investigators (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl099 · Cited by 653 · see citing works
Moss, A. J., Greenberg, H., Case, R. B., Zaręba, W., Hall, W. J., Brown, M. W., Daubert, J. P., McNitt, S. A., Andrews, M. L., & Elkin, A. D. (2004) · Circulation · doi:10.1161/01.cir.0000150390.04704.b7 · Cited by 599 · see citing works
Integration and generalization of kappas for multiple raters
Conger, A. J. (1980) · Psychological Bulletin · doi:10.1037/0033-2909.88.2.322 · Cited by 545 · see citing works
Cost-Effectiveness of Implantable Cardioverter–Defibrillators
Sanders, G. D., Hlatky, M. A., & Owens, D. K. (2005) · New England Journal of Medicine · doi:10.1056/nejmsa051989 · Cited by 543 · see citing works
Goldenberg, I., Vyas, A. K., Hall, W. J., Moss, A. J., Wang, H., He, H., Zaręba, W., McNitt, S. A., & Andrews, M. L. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.058 · Cited by 530 · see citing works
Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M. L., Konstam, M. A., MANCINI, D. M., Michl, K., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167587 · Cited by 461 · see citing works
Hernandez, A. F., Fonarow, G. C., Liang, L., Al‐Khatib, S. M., Curtis, L. H., LaBresh, K. A., Yancy, C. W., Albert, N. M., & Peterson, E. D. (2007) · JAMA · doi:10.1001/jama.298.13.1525 · Cited by 419 · see citing works
A Meta-Analysis of Remote Monitoring of Heart Failure Patients
Klersy, C., Silvestri, A. D., Gabutti, G., Regoli, F. D., & Auricchio, A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.017 · Cited by 379 · see citing works
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364 · see citing works
Self-citationSaxon, L. A., Bristow, M. R., BOEHMER, J. P., Krueger, S., Kass, D. A., Marco, T. D., Carson, P. E., DiCarlo, L. A., Feldman, A. M., Galle, E. G., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.642892 · Cited by 288 · see citing works
Self-citationMehrotra, A., Liu, H., Adams, J., Wang, M. C., Lave, J. R., Thygeson, N. M., Solberg, L. I., & McGlynn, E. A. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-5-200909010-00006 · Cited by 246 · see citing works
The Cost Effectiveness of Implantable Cardioverter-Defibrillators
Zwanziger, J., Hall, W. J., Dick, A. W., Zhao, H., Mushlin, A. I., Hahn, R., Wang, H., Andrews, M. L., Mooney, C., Wang, H., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.032 · Cited by 221 · see citing works
Heart Failure Care in the Outpatient Cardiology Practice Setting
Fonarow, G. C., Yancy, C. W., Albert, N. M., Curtis, A. B., Stough, W. G., Gheorghiade, M., Heywood, J. T., McBride, M. L., Mehra, M. R., O’Connor, C. M., et al. (2008) · Circulation Heart Failure · doi:10.1161/circheartfailure.108.772228 · Cited by 185 · see citing works
Feldman, A. M., de Lissovoy, G., Bristow, M. R., Saxon, L. A., Marco, T. D., Kass, D. A., BOEHMER, J. P., Singh, S. N., Whellan, D. J., Carson, P. E., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.033 · Cited by 184 · see citing works
Self-citationMcClellan, M., & Tunis, S. (2005) · New England Journal of Medicine · doi:10.1056/nejmp048354 · Cited by 153 · see citing works
Hammill, S. C., Kremers, M. S., Kadish, A. H., Stevenson, L. W., Heidenreich, P. A., Lindsay, B. D., Mirro, M. J., Radford, M. J., McKay, C., Wang, Y., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.07.015 · Cited by 91 · see citing works
Self-citationSelecting Patients for Discussion of the ICD as Primary Prevention for Sudden Death in Heart Failure
Stevenson, L. W., & Desai, A. S. (2006) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.06.001 · Cited by 75 · see citing works
Body Computing: How Networked Medical Devices Can Solve Problems Facing Health Care Today
Saxon, L. A., & Rao, A. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01005.x · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Alba, A. C., Agoritsas, T., Walsh, M., Hanna, S., Iorio, A., Devereaux, P. J., McGinn, T., & Guyatt, G. (2017) · JAMA · doi:10.1001/jama.2017.12126 · Cited by 1,631 · see citing works
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467 · see citing works
Self-citationLandolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344 · see citing works
Lampert, R., Olshansky, B., Heidbuchel, H., Lawless, C., Saarel, E., Ackerman, M., Calkins, H., Estes, N. A. M., Link, M. S., Maron, B. J., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000447 · Cited by 286 · see citing works
Klersy, C., Boriani, G., De Silvestri, A., Mairesse, G. H., Braunschweig, F., Scotti, V., Balduini, A., Cowie, M. R., Leyva, F., & for the Health Economics Committee of the European Heart Rhythm Association (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.470 · Cited by 120 · see citing works
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102 · see citing works
Cardiac resynchronization therapy: state of the art 2013
Yu, C.-M., & Hayes, D. L. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs454 · Cited by 68 · see citing works
Self-citationDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47 · see citing works
Self-citationManaging with pacemakers and implantable cardioverter defibrillators
Lampert, R. (2013) · Circulation · doi:10.1161/circulationaha.113.001555 · Cited by 34 · see citing works
Ruwald, M. H., Zareba, W., Jons, C., Zhang, C., Ruwald, A.-C. H., Olshansky, B., McNitt, S., Bloch Thomsen, P. E., Shoda, M., Merkely, B., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002472 · Cited by 30 · see citing works
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28 · see citing works
- Authors
- Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P.
- Affiliations
- University of Southern California (US)
- ORCID
- Venue
- Circulation
- Published
- 2010-12-07
- Volume
- 122
- Issue
- 23
- Pages
- 2359-2367
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2034311573
- Cited by
- 515
- References
- 26
- Citations by year
- 2026: 8 · 2025: 16 · 2024: 11 · 2023: 26 · 2022: 25 · 2021: 29 · 2020: 33 · 2019: 31 · 2018: 19 · 2017: 46 · 2016: 51 · 2015: 43 · 2014: 43 · 2013: 61 · 2012: 49
- FWCI
- 28.89
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable cardioverter-defibrillator, CRT-D, remote device monitoring, mortality risk, device follow-up, electrogram analysis
- MeSH terms
- Aged, Aged, 80 and over, Altitude, Convulsive Therapy, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Time Factors, Survival Rate, Treatment Outcome, Defibrillators, Implantable, Cardiac Resynchronization Therapy, Remote Sensing Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review