Artificial Intelligence–Enabled Assessment of the Heart Rate Corrected QT Interval Using a Mobile Electrocardiogram Device
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: Heart rate–corrected QT interval (QTc) prolongation, whether secondary to drugs, genetics including congenital long QT syndrome, and/or systemic diseases including SARS-CoV-2–mediated coronavirus disease 2019 (COVID-19), can predispose to ventricular arrhythmias and sudden cardiac death. Currently, QTc assessment and monitoring relies largely on 12-lead electrocardiography. As such, we sought to train and validate an artificial intelligence (AI)–enabled 12-lead ECG algorithm to determine the QTc, and then prospectively test this algorithm on tracings acquired from a mobile ECG (mECG) device in a population enriched for repolarization abnormalities. Methods: Using >1.6 million 12-lead ECGs from 538 200 patients, a deep neural network (DNN) was derived (patients for training, n = 250 767; patients for testing, n = 107 920) and validated (n = 179 513 patients) to predict the QTc using cardiologist-overread QTc values as the “gold standard”. The ability of this DNN to detect clinically-relevant QTc prolongation (eg, QTc ≥500 ms) was then tested prospectively on 686 patients with genetic heart disease (50% with long QT syndrome) with QTc values obtained from both a 12-lead ECG and a prototype mECG device equivalent to the commercially-available AliveCor KardiaMobile 6L. Results: In the validation sample, strong agreement was observed between human over-read and DNN-predicted QTc values (−1.76±23.14 ms). Similarly, within the prospective, genetic heart disease–enriched dataset, the difference between DNN-predicted QTc values derived from mECG tracings and those annotated from 12-lead ECGs by a QT expert (−0.45±24.73 ms) and a commercial core ECG laboratory [10.52±25.64 ms] was nominal. When applied to mECG tracings, the DNN’s ability to detect a QTc value ≥500 ms yielded an area under the curve, sensitivity, and specificity of 0.97, 80.0%, and 94.4%, respectively. Conclusions: Using smartphone-enabled electrodes, an AI DNN can predict accurately the QTc of a standard 12-lead ECG. QTc estimation from an AI-enabled mECG device may provide a cost-effective means of screening for both acquired and congenital long QT syndrome in a variety of clinical settings where standard 12-lead electrocardiography is not accessible or cost-effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Priori, S. G., Wilde, A. A., Horie, M., Cho, Y., Behr, E. R., Berul, C., Blom, N., Brugada, J., Chiang, C.-E., Huikuri, H., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.05.014 · Cited by 1,942
Multitarget Stool DNA Testing for Colorectal-Cancer Screening
Imperiale, T. F., Ransohoff, D. F., Itzkowitz, S. H., Levin, T. R., Lavin, P., Lidgard, G. P., Ahlquist, D. A., & Berger, B. M. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311194 · Cited by 1,900
Drew, B. J., Ackerman, M. J., Funk, M., Gibler, W. B., Kligfield, P., Menon, V., Philippides, G. J., Roden, D. M., & Zareba, W. (2010) · Circulation · doi:10.1161/circulationaha.109.192704 · Cited by 821
Self-citationKo, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404
Self-citationGalloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318
Self-citationWatson, M. S., Lloyd-Puryear, M. A., Mann, M. Y., Rinaldo, P., & Howell, R. R. (2006) · Genetics in Medicine · doi:10.1097/01.gim.0000223467.60151.02 · Cited by 93
Cited by
Application of artificial intelligence to the electrocardiogram
Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab649 · Cited by 312
Self-citationHow to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Chung, C. T., Lee, S., King, E., Liu, T., Armoundas, A. A., Bazoukis, G., & Tse, G. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00075-x · Cited by 79
Moving towards vertically integrated artificial intelligence development
Zhang, J., Budhdeo, S., William, W., Cerrato, P., Shuaib, H., Sood, H., Ashrafian, H., Halamka, J., & Teo, J. T. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00690-x · Cited by 54
Bleijendaal, H., Croon, P. M., Pool, M. D. O., Malekzadeh, A., Aufiero, S., Amin, A. S., Zwinderman, A. H., Pinto, Y. M., Wilde, A. A. M., & Winter, M. M. (2023) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2022.01.011 · Cited by 17
Metadata
- Authors
- Giudicessi, J. R., Schram, M., Bos, J. M., Galloway, C. D., Shreibati, J. B., Johnson, P. W., Carter, R. E., Disrud, L. W., Kleiman, R., Attia, Z. I., Noseworthy, P. A., Friedman, P. A., Albert, D. E., & Ackerman, M. J.
- Venue
- Circulation
- Published
- 2021-03-30
- Volume
- 143
- Issue
- 13
- Pages
- 1274-1286
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3128824338
- Cited by
- 129
- References
- 8
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Intelligence–Enabled Assessment of the Heart Rate Corrected QT Interval Using a Mobile Electrocardiogram Device. https://app.cochat.ai/papers/10.1161/circulationaha.120.050231
- The paper
- Giudicessi, J. R., Schram, M., Bos, J. M., Galloway, C. D., Shreibati, J. B., Johnson, P. W., Carter, R. E., Disrud, L. W., Kleiman, R., Attia, Z. I., Noseworthy, P. A., Friedman, P. A., Albert, D. E., & Ackerman, M. J. (2021). Artificial Intelligence–Enabled Assessment of the Heart Rate Corrected QT Interval Using a Mobile Electrocardiogram Device. Circulation. https://doi.org/10.1161/circulationaha.120.050231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.