CoChat

Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator? Results From the Multicenter Randomized PARTITA Trial

Della Bella, Paolo, Baratto, Francesca, Vergara, Pasquale, Bertocchi, Patrizia, Santamaria, Matteo, Notarstefano, Pasquale, Calò, Leonardo, Orsida, Daniela, Tomasi, Luca, Piacenti, Marcello, Sangiorgio, Stefano, Pentimalli, Francesco, Pruvot, Etienne, De Sousa, João, Sacher, Frederic, Tritto, Massimo, Rebellato, Luca, Deneke, Thomas, Romano, Salvo Andrea, Nesti, Martina, Gargaro, Alessio, Giacopelli, Daniele, Peretto, Giovanni, Radinovic, Andrea · 2022 · Circulation
Cited by 204

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Optimal timing for catheter ablation of ventricular tachycardia is an important unresolved issue. There are no randomized trials evaluating the benefit of ablation after the first implantable cardioverter defibrillator (ICD) shock. Methods: We conducted a 2-phase, prospective, multicenter, randomized clinical trial. Patients with ischemic or nonischemic dilated cardiomyopathy and primary or secondary prevention indication for ICD were enrolled in an initial observational phase until first appropriate shock (phase A). After reconsenting, patients were randomly assigned 1:1 in phase B to immediate ablation (within 2 months from shock delivery) or continuation of standard therapy. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Amiodarone intake was not allowed except for documented atrial tachyarrhythmias. On July 23, 2021, phase B of the trial was interrupted as a result of the first interim analysis on the basis of the Bayesian adaptive design. Results: Of the 517 patients enrolled in phase A, 154 (30%) had ventricular tachycardia, 56 (11%) received an appropriate shock over a median follow-up of 2.4 years (interquartile range, 1.4–4.4), and 47 of 56 (84%) agreed to participate in phase B. After 24.2 (8.5–24.4) months, the primary end point occurred in 1 of 23 (4%) patients in the ablation group and 10 of 24 (42%) patients in the control group (hazard ratio, 0.11 [95% CI, 0.01–0.85]; P =0.034). The results met the prespecified termination criterion of >99% Bayesian posterior probability of superiority of treatment over standard therapy. No deaths were observed in the ablation group versus 8 deaths (33%) in the control group ( P =0.004); there was 1 worsening heart failure hospitalization in the ablation group (4%) versus 4 in the control group (17%; P =0.159). ICD shocks were less frequent in the ablation group (9%) than in the control group (42%; P =0.039). Conclusions: Ventricular tachycardia ablation after first appropriate shock was associated with a reduced risk of the combined death or worsening heart failure hospitalization end point, lower mortality, and fewer ICD shocks. These findings provide support for considering ventricular tachycardia ablation after the first ICD shock. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01547208.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.122.059598

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Della Bella, P., Baratto, F., Vergara, P., Bertocchi, P., Santamaria, M., Notarstefano, P., Calò, L., Orsida, D., Tomasi, L., Piacenti, M., Sangiorgio, S., Pentimalli, F., Pruvot, E., De Sousa, J., Sacher, F., Tritto, M., Rebellato, L., Deneke, T., Romano, S. A., Nesti, M., Gargaro, A., Giacopelli, D., Peretto, G., & Radinovic, A.
Venue
Circulation
Published
2022-06-21
Volume
145
Issue
25
Pages
1829-1838
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W4225956500
Cited by
204
References
3
FWCI
25.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.