The DOI matches its Crossref record.
TIMI Myocardial Perfusion Grade and ST Segment Resolution: Association With Infarct Size as Assessed by Single Photon Emission Computed Tomography Imaging
Abstract
Background — The TIMI myocardial perfusion grade (TMPG) and ST-segment resolution both reflect perfusion and are associated with mortality after thrombolysis for acute myocardial infarction. We hypothesized that these measures would also be associated with infarct size by single photon emission computed tomography (SPECT). Methods and Results — In the LIMIT AMI trial (Limitation of Myocardial Injury following Thrombolysis in Acute Myocardial Infarction) of lytic monotherapy versus lytic plus rhuMAb CD18, early 90-minute TMPG (n=221) and ST segment resolution (n=242) were compared with subsequent SPECT Technetium-99 m Sestamibi, measuring the percentage of the left ventricle with no Sestamibi uptake. Infarct sizes were larger with TMPG 0 or 1 (a closed or stained myocardium) than with TMPG 2 or 3 (open myocardium, median 13% versus 7%, P =0.004). Infarcts were also larger in patients with no ST segment resolution (median 15%) or incomplete resolution (11%) than in those with complete resolution (6%, overall P =0.0001). The difference in infarct size by TMPG persisted when stratified by category of ST resolution. Conclusions — There may be a pathophysiological link between early restoration of tissue-level perfusion and reduced subsequent infarct size that may partially explain why these early angiographic and electrocardiographic measures are associated with long-term survival.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van't Hof, A. W., ten Berg, J., Heestermans, T., Dill, T., Funck, R. C., van Werkum, W., Dambrink, J.-H. E., Suryapranata, H., van Houwelingen, G., Ottervanger, J. P., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61235-0 · Cited by 512
Use of the Electrocardiogram in Acute Myocardial Infarction
Zimetbaum, P. J., & Josephson, M. E. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022700 · Cited by 433
Angiographic Assessment of Reperfusion in Acute Myocardial Infarction by Myocardial Blush Grade
Henriques, J. P. S., Zijlstra, F., van ‘t Hof, A. W. J., de Boer, M.-J., Dambrink, J.-H. E., Gosselink, M., Hoorntje, J. C. A., & Suryapranata, H. (2003) · Circulation · doi:10.1161/01.cir.0000065221.06430.ed · Cited by 400
Acute Coronary Syndromes: Diagnosis and Management, Part II
Kumar, A., & Cannon, C. P. (2009) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)60674-5 · Cited by 336
Ali, A., Cox, D., Dib, N., Brodie, B., Berman, D., Gupta, N., Browne, K., Iwaoka, R., Azrin, M., Stapleton, D., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.044 · Cited by 288
Metadata
- Authors
- Angeja, B. G., Gunda, M., Murphy, S. A., Sobel, B. E., Rundle, A. C., Syed, M., Asfour, A., Borzak, S., Gourlay, S. G., Barron, H. V., Gibbons, R. J., & Gibson, C. M.
- Venue
- Circulation
- Published
- 2002-01-22
- Volume
- 105
- Issue
- 3
- Pages
- 282-285
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2129228709
- Cited by
- 160
- References
- 0
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: TIMI Myocardial Perfusion Grade and ST Segment Resolution: Association With Infarct Size as Assessed by Single Photon Emission Computed Tomography Imaging. https://app.cochat.ai/papers/10.1161/hc0302.103588
- The paper
- Angeja, B. G., Gunda, M., Murphy, S. A., Sobel, B. E., Rundle, A. C., Syed, M., Asfour, A., Borzak, S., Gourlay, S. G., Barron, H. V., Gibbons, R. J., & Gibson, C. M. (2002). TIMI Myocardial Perfusion Grade and ST Segment Resolution: Association With Infarct Size as Assessed by Single Photon Emission Computed Tomography Imaging. Circulation. https://doi.org/10.1161/hc0302.103588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.