Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 400

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Angiographic Assessment of Reperfusion in Acute Myocardial Infarction by Myocardial Blush Grade

Open access
Henriques, Jose P.S., Zijlstra, Felix, van ‘t Hof, Arnoud W.J., de Boer, Menko-Jan, Dambrink, Jan-Henk E., Gosselink, Marcel, Hoorntje, Jan C.A., Suryapranata, Harry · 2003 · Circulation

Abstract

Background— Angiographic successful reperfusion in acute myocardial infarction has been defined as TIMI 3 flow. However, TIMI 3 flow does not always result in effective myocardial reperfusion. Myocardial blush grade (MBG) is an angiographic measure of myocardial perfusion. We hypothesized that optimal angiographic reperfusion is defined by TIMI 3 flow and MBG 2 or 3. Methods and Results— In 924 consecutive patients with TIMI 3 flow after angioplasty for acute myocardial infarction, we prospectively studied the value of MBG. End points were death, MACE, enzymatic infarct size, and residual left ventricular ejection fraction. Follow-up was 16±11 months. Of the 924 patients, 101 (11%) patients had MBG 0 or 1. Mortality was significantly higher in patients with MBG 0 or 1 compared with patients with MBG 2 or 3 (relative risk, 4.7; 95% CI, 2.3 to 9.5; P <0.001). The combined incidence of MACE was higher in patients with MBG 0 or 1 compared with patients with MBG 2 or 3 (relative risk, 1.8; 95% CI, 1.1 to 2.8; P =0.009). Enzymatic infarct size was larger (1437±2388 versus 809±1672, P =0.001) and left ventricular ejection fraction was lower (37.7±10.6 versus 43.8±11.1, P <0.001) in patients with MBG 0 or 1 compared with patients with MBG 2 or 3. Conclusions— MBG is a strong angiographic predictor of mortality in patients with TIMI 3 flow after primary angioplasty. Enzymatic infarct size is larger and residual left ventricular ejection fraction is lower in patients with MBG 0 or 1 compared with MBG 2 or 3. Angiographic definition of successful reperfusion should include both TIMI 3 flow as well as MBG 2 or 3.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000065221.06430.ed

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 400

Metadata

Authors
Henriques, J. P. S., Zijlstra, F., van ‘t Hof, A. W. J., de Boer, M.-J., Dambrink, J.-H. E., Gosselink, M., Hoorntje, J. C. A., & Suryapranata, H.
Venue
Circulation
Published
2003-04-29
Volume
107
Issue
16
Pages
2115-2119
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2026748919
Cited by
400
References
34
FWCI
14.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Angiographic Assessment of Reperfusion in Acute Myocardial Infarction by Myocardial Blush Grade. https://app.cochat.ai/papers/10.1161/01.cir.0000065221.06430.ed
The paper
Henriques, J. P. S., Zijlstra, F., van ‘t Hof, A. W. J., de Boer, M.-J., Dambrink, J.-H. E., Gosselink, M., Hoorntje, J. C. A., & Suryapranata, H. (2003). Angiographic Assessment of Reperfusion in Acute Myocardial Infarction by Myocardial Blush Grade. Circulation. https://doi.org/10.1161/01.cir.0000065221.06430.ed

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.