The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators Trial: Impact of Therapy and Influence of Adverse Symptoms and Defibrillator Shocks
Abstract
Background — Implantable cardioverter defibrillator (ICD) use reduces mortality in patients with serious ventricular arrhythmias compared with antiarrhythmic drug (AAD) use. However, the relative impact of these therapies on self-perceived quality of life (QoL) is unknown. Methods and Results — Three self-administered instruments were used to measure generic and disease-specific QoL in Antiarrhythmics Versus Implantable Defibrillators trial participants. Generalized linear models were used to assess the relationships between self-perceived QoL and treatment (AAD versus ICD) and adverse symptoms and ICD shocks. To minimize the impact of missing data, only patients surviving 1 year were included in the primary analyses. Baseline characteristics among QoL participants (n=905) and nonparticipants (n=111) were similar, but participants who survived 1 year (n=800) were healthier at baseline than nonsurvivors (n=105). Of the 800 patients in the primary analysis, characteristics of those randomized to AAD (n=384) versus ICD (n=416) were similar. Overall, ICD and AAD use were associated with similar alterations in QoL. The development of sporadic shocks and adverse symptoms were each associated with reduced physical functioning and mental well-being and increased concerns among ICD recipients, whereas development of adverse symptoms was associated with reduced physical functioning and increased concerns among AAD recipients. Conclusions — ICD and AAD therapy are associated with similar alterations in self-perceived QoL over 1-year follow-up. Adverse symptoms were associated with reduced self-perceived QoL in both groups, and sporadic shocks were associated with reduced QoL in ICD recipients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Further, there was greater reduction in QOL as the number of shocks increased.”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [5]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In the Antiarrhythmics Versus Implanted Defibrillators (AVID) trial, baseline QOL measured by SF-36 in ICD patients was similar to that of elderly patients with recent myocardial infarction or severe heart failure, but less than for ambulatory patients with heart failure”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“Similarly, in the AVID trial, 5 the occurrence of even 1 shock was associated with a reduction in mental well-being and physical function, even after controlling for multiple clinical factors such as heart failure, index arrhythmia, and ejection fraction.”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“As described above, many studies suggest that ICD shocks can decrease QOL.96”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [96]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
SF-36 health survey: Manual and interpretation guide
Ware, J. (2003) · Medical Entomology and Zoology · Cited by 11,424
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
Self-citationFunctional Status and Well-being of Patients With Chronic Conditions
Stewart, A. L. (1989) · JAMA · doi:10.1001/jama.1989.03430070055030 · Cited by 2,309
Fundamentals of Clinical Trials
Friedman, L. M., Furberg, C. D., DeMets, D. L., Reboussin, D. M., & Granger, C. B. (2015) · doi:10.1007/978-3-319-18539-2 · Cited by 2,237
A Critical Appraisal of the Quality of Quality-of-Life Measurements
Gill, T. M. (1994) · JAMA · doi:10.1001/jama.1994.03520080061045 · Cited by 2,209
Measuring Health-Related Quality of Life
Guyatt, G., Feeny, D., & Patrick, D. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-8-199304150-00009 · Cited by 2,168
Stewart, A. L. (1989) · JAMA · doi:10.1001/jama.262.7.907 · Cited by 2,095
Flagged first, then by citations
Research works printed but not linked: 2
- Croog SH. Current issues in conceptualizing and measuring quality of life. In: Quality of Life Assessment: Practice Problems and Promise. Proceedings of a workshop sponsored by the Office of the Director National Institutes of Health. NIH Publication No. 93-3503; 1990.
- 10.1161/circ.103.16.2066 · DOI
Cited by
Sorted by citations
Items 201–300 of 624
Salmoirago‐Blotcher, E., Crawford, S. L., Carmody, J., ROSENTHAL, L. S., Yeh, G. Y., Stanley, M. G., Rose, K., Browning, C., & Ockene, I. S. (2013) · Annals of Behavioral Medicine · doi:10.1007/s12160-013-9505-7 · Cited by 34
Role of repeat procedures for catheter ablation of postinfarction ventricular tachycardia
Kosmidou, I., Inada, K., Seiler, J., Koplan, B. A., Stevenson, W. G., & Tedrow, U. B. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.06.021 · Cited by 33
Zeigler, V. L., & Decker-Walters, B. (2010) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0b013e3181d817b0 · Cited by 33
The Effect of Shock Burden on Heart Failure and Mortality
Macintyre, C. J., Sapp, J. L., AbdelWahab, A. M., Alharbi, M., Doucette, S. P., Gray, C., Gardner, M. J., & Parkash, R. (2019) · CJC Open · doi:10.1016/j.cjco.2019.04.003 · Cited by 33
Quality of Life Outcomes in Chinese Patients with Implantable Cardioverter Defibrillators
Chair, S. Y., LEE, C. K., Choi, K. C., & Sears, S. F. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03048.x · Cited by 33
Electrophysiologic characteristics of anger-triggered arrhythmias
Stopper, M. M., Joska, T. M., Burg, M. M., Batsford, W. P., McPherson, C. A., Jain, D., & Lampert, R. J. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.11.003 · Cited by 33
Pedersen, S. S., Spek, V., Theuns, D. A. M. J., Alings, M., van der Voort, P., Jordaens, L. J. L. M., Cuijpers, P. J., Denollet, J., & van den Broek, K. C. (2009) · Trials · doi:10.1186/1745-6215-10-120 · Cited by 32
Rahmawati, A., Chishaki, A. S., Sawatari, H., Tsuchihashi‐Makaya, M., Ohtsuka, Y., Nakai, M., Miyazono, M., Hashiguchi, N., Sakurada, H., Takemoto, M., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-12-1116 · Cited by 32
Implantable cardioverter-defibrillator shock prevention does not reduce mortality: A systemic review
Ha, A. H., Ham, I., Nair, G. M., Connolly, S. J., Dorian, P., Morillo, C. A., & Healey, J. S. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.08.032 · Cited by 31
Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods
Manzoni, G. M., Castelnuovo, G., Compare, A., Pagnini, F., Essebag, V., & Proietti, R. (2015) · Frontiers in Psychology · doi:10.3389/fpsyg.2015.00039 · Cited by 32
You, J. J., Woo, A., Ko, D. T., CAMERON, D. A., Mihailovic, A., & Krahn, M. D. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.06.026 · Cited by 31
Barsheshet, A., Goldenberg, I., Narins, C. R., Moss, A. J., McNitt, S. A., Wang, P. J., Huang, D. T.-C., Hall, W. J., Zaręba, W., Eldar, M., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.07.005 · Cited by 31
Ferrari, G. M. D., & Sanzo, A. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.008 · Cited by 31
Catheter Ablation for Scar-related Ventricular Tachycardias
Raymond, J., Sacher, F., Winslow, R., Tedrow, U. B., & Stevenson, W. G. (2009) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2009.01.002 · Cited by 30
Kim, E., Davogustto, G., Stevenson, W. G., & John, R. M. (2018) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.7.1.eo1 · Cited by 30
do Carmo, A. A. L., de Sousa, M. R., Agudelo, J. F., Boersma, E. H., Rocha, M. O. D. C., Ribeiro, A. L. P., & Morillo, C. A. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.05.091 · Cited by 30
Wright, G. A., Klein, G. J., & Gula, L. J. (2012) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e32835b0b3b · Cited by 29
Implantable cardioverter defibrillators: risks accompany the life-saving benefits
Atwater, B. D., & Daubert, J. P. (2012) · Heart · doi:10.1136/heartjnl-2012-301853 · Cited by 29
Evaluation and Management of Arrhythmia in the Athletic Patient
Lampert, R. J. (2012) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.01.002 · Cited by 31
Implantable cardiac defibrillators for people with non-ischaemic cardiomyopathy
Moheb, M. N. E., Nicolas, J., Khamis, A. M., Iskandarani, G., Akl, E. A., & Refaat, M. M. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012738.pub2 · Cited by 30
Team Management of the Ventricular Tachycardia Patient
Tang, P., Do, D. H., Li, A. C., & Boyle, N. G. (2018) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2018.37.2 · Cited by 29
Deactivation of Implantable Cardioverter Defibrillator in Patients With Terminal Diagnoses
Trussler, A., Alexander, B., Campbell, D., Alhammad, N. J., Enriquez, A. A., Chacko, S. M., Garrett, T. J., Simpson, C., Redfearn, D., Abdollah, H., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.07.007 · Cited by 29
Gopinathannair, R., Lerew, D. R., Cross, N. J., Sears, S. F., Brown, S., & Olshansky, B. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0233-y · Cited by 28
The Role of Antiarrhythmic Drug Therapy for the Prevention of Sudden Cardiac Death
Kamath, G. S., & Mittal, S. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.12.001 · Cited by 28
Lloyd, M. S., Brisben, A., Reddy, V. Y., Blomström‐Lundqvist, C., Boersma, L. V. A., Bongiorni, M. G., Burke, M. C., Cantillon, D. J., Doshi, R. N., Friedman, P. A., et al. (2023) · Heart Rhythm O2 · doi:10.1016/j.hroo.2023.05.004 · Cited by 27
Self-citationState‐of‐the‐art: anxiety management in patients with implantable cardioverter defibrillators
Sears, S. F., Vazquez, L. D., Matchett, M., & Pitzalis, M. V. (2008) · Stress and Health · doi:10.1002/smi.1200 · Cited by 27
Bryant, J., Brodin, H., Loveman, E., & Clegg, A. J. (2007) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462307051586 · Cited by 27
Delacrétaz, E., Brenner, R., Schaumann, A., Eckardt, L., Willems, S., Pitschner, H.-F., Kautzner, J., Schumacher, B., HANSEN, P. S., & Kück, K. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12073 · Cited by 26
Implantable Cardioverter–Defibrillator Use in Older Adults
Kramer, D. B., Matlock, D. D., Buxton, A. E., Goldstein, N. E., Goodwin, C., Green, A. R., Kirkpatrick, J. N., Knoepke, C. E., Lampert, R. J., Mueller, P. S., et al. (2015) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.114.001660 · Cited by 26
Francia, P., Balla, C., Uccellini, A., & Cappato, R. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01477.x · Cited by 26
Birnie, D. H., Sears, S. F., Green, M. S., Lemery, R., Gollob, M. H., & AMYOTTE, B. (2008) · EP Europace · doi:10.1093/europace/eun317 · Cited by 26
Heart Failure and Sudden Cardiac Death
Saour, B., Smith, B., & Yancy, C. W. (2017) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2017.07.010 · Cited by 27
Çınar, F. İ., Tosun, N., & Köse, S. (2013) · Journal of Clinical Nursing · doi:10.1111/jocn.12201 · Cited by 25
Perceived control and quality of life among recipients of implantable cardioverter defibrillator
Hammash, M., McEvedy, S. M., Wright, J. H., Cameron, J., Miller, J., Ski, C. F., Thompson, D. R., Biddle, M., Wimsatt, A., Schrader, M., et al. (2018) · Australian Critical Care · doi:10.1016/j.aucc.2018.08.005 · Cited by 25
Carroll, D. L., Hamilton, G. A., & Kenney, B. J. (2002) · European Journal of Cardiovascular Nursing · doi:10.1016/s1474-5151(02)00040-3 · Cited by 25
Mauro, A. M. P. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2010.02.003 · Cited by 25
Educational intervention for patients with automatic implantable cardioverter defibrillators.
Edelman, S., Lemon, J., & Kirkness, A. (2007) · PubMed · Cited by 25
Pokorney, S. D., Friedman, D. J., Calkins, H. G., Callans, D. J., Daoud, E. G., Bella, P. E. D., JACKSON, K. P., Shivkumar, K., Saba, S., Sapp, J. L., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.04.001 · Cited by 24
Shock to the Heart: Psychosocial Implications and Applications of Sudden Cardiac Death in the Young
Grubic, N., Puskas, J., Phelan, D. M. J., Fournier, A., Martin, L. J., & Johri, A. M. (2020) · Current Cardiology Reports · doi:10.1007/s11886-020-01419-6 · Cited by 24
Almost Normal: Experiences of Adolescents With Implantable Cardioverter Defibrillators
Zeigler, V. L., & Nelms, T. P. (2009) · Journal for Specialists in Pediatric Nursing · doi:10.1111/j.1744-6155.2009.00186.x · Cited by 24
Gandjour, A., Dipl-Ges-Ök, A. H., & Adarkwah, C. C. (2011) · Value in Health · doi:10.1016/j.jval.2011.02.1180 · Cited by 24
Bhavnani, S. P., Coleman, C. I., White, C. M., Clyne, C. A., Yarlagadda, R. B., Guertin, D., & Kluger, J. (2008) · EP Europace · doi:10.1093/europace/eun128 · Cited by 24
Patel, D. R., Hasselblad, V., JACKSON, K. P., Pokorney, S. D., Daubert, J. P., & Al‐Khatib, S. M. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0083-4 · Cited by 24
Marshall, P., Malecki-Ketchell, A., & Maclean, J. (2011) · European Journal of Cardiovascular Nursing · doi:10.1016/j.ejcnurse.2011.06.010 · Cited by 25
Quality of life with ablation or medical therapy for ventricular arrhythmias: A substudy of VANISH
Gula, L. J., Doucette, S. P., Leong‐Sit, P., TANG, A. S. L., Parkash, R., SARRAZIN, J., Thibault, B., Essebag, V., Tung, S., Deyell, M. W., et al. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13419 · Cited by 24
Rajawat, Y. S., Patel, V. V., Gerstenfeld, E. P., Nayak, H. M., & Marchlinski, F. E. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00702.x · Cited by 24
Feingold, B., Arora, G., Webber, S. A., & Smith, K. J. (2010) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2010.04.009 · Cited by 23
Crespo, E. M., Selzman, K. A., Kim, J., Steinhoff, J. P., & Sheahan, R. G. (2005) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200505000-00005 · Cited by 23
Factors related to quality-of-life pattern changes in recipients of implantable defibrillators
Dickerson, S. S., Kennedy, M., Wu, Y. B., Underhill-Blazey, M. L., & Othman, A. (2010) · Heart & Lung · doi:10.1016/j.hrtlng.2009.10.022 · Cited by 23
Younes, A. T., Al-Kindi, S. G., Alajaji, W., Mackall, J. A., & Oliveira, G. H. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.12.148 · Cited by 23
Lee, C. H., Nam, G., Park, H.-G., Kim, H. Y., Park, K., Kim, J., Choi, K., & Kim, Y. (2007) · Circulation Journal · doi:10.1253/circj.72.102 · Cited by 23
Goldenberg, I., & Moss, A. J. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.09.002 · Cited by 23
Effect of Baseline Antiarrhythmic Drug on Outcomes With Ablation in Ischemic Ventricular Tachycardia
Parkash, R., Nault, I., Rivard, L., Gula, L. J., Essebag, V., Nery, P. B., Tung, S., Raymond, J., Sterns, L. D., Doucette, S. P., et al. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.005663 · Cited by 22
Management of Ventricular Arrhythmias in Patients with Mechanical Ventricular Support Devices
Healy, C., Viles-González, J. F., Sacher, F., Coffey, J. O., & d’Ávila, A. (2015) · Current Cardiology Reports · doi:10.1007/s11886-015-0617-5 · Cited by 21
Implantation of cardioverter-defibrillator: Effects on shoulder function
Diemberger, I., Pegreffi, F., Mazzotti, A., Foschi, E., Martignani, C., Belli, G., Biffi, M., Ziacchi, M., Branzi, A., Grigioni, F., et al. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.09.071 · Cited by 22
Quality of Death: Implantable Cardioverter Defibrillators and Proactive Care
Sears, S. F., Sowell, L. V., Kuhl, E. A., Handberg, E. M., Kron, J., Aranda, J. M., & CONTI, J. B. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00412.x · Cited by 22
Cardiac Pacing and Defibrillation Devices: Cost and Effectiveness
Groeneveld, P. W., & Dixit, S. (2016) · Annual Review of Medicine · doi:10.1146/annurev-med-043015-123540 · Cited by 23
Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks
Beau, S. L., Greer, S., Ellis, C. R., Keeney, J., Asopa, S., Arnold, E., & Fischer, A. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0081-6 · Cited by 21
Sivagangabalan, G., Eshoo, S., EIPPER, V. E., Thiagalingam, A., & Kovoor, P. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01147.x · Cited by 21
Predictors of Implantable Cardioverter Defibrillator Shocks During the First Year
Dougherty, C. M., & Hunziker, J. (2009) · The Journal of Cardiovascular Nursing · doi:10.1097/01.jcn.0000317473.42801.a8 · Cited by 21
Partner Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators Trial
Jenkins, L. S., Powell, J. L., SCHRON, E. B., McBurnie, M. A., Bosworth-Farrell, S., Moore, R., & Exner, D. V. (2007) · The Journal of Cardiovascular Nursing · doi:10.1097/01.jcn.0000297378.98754.06 · Cited by 21
Self-citationVersteeg, H., Baumert, J. J., Kolb, C., Pedersen, S. S., Denollet, J., Ronel, J., & Ladwig, K. (2010) · Health Psychology · doi:10.1037/a0020337 · Cited by 21
Fritzsche, K., Forster, F., Schweickhardt, A., Kanwischer, H., Drinkmann, A., Rabung, S., Bergmann, G., Geibel, A., & Herrmann‐Lingen, C. (2007) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2007.07.003 · Cited by 21
Kuhl, E. A., Sears, S. F., & CONTI, J. B. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00558.x · Cited by 21
A benefit–risk assessment of class III antiarrhythmic agents
Elming, H., Brendorp, B., Pehrson, S. M., Pedersen, O. D., Køber, L., & Torp-Petersen, C. (2004) · Expert Opinion on Drug Safety · doi:10.1517/14740338.3.6.559 · Cited by 21
Impact of ventricular tachycardia ablation on health care utilization
Winterfield, J. R., Kent, A. R., Karst, E., Dalal, N., Mahapatra, S., Bunch, T. J., Reynolds, M. R., & Wilber, D. J. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.009 · Cited by 20
Expanding the Scope of Practice for Cardiac Rehabilitation
Sears, S. F., Kovacs, A. H., CONTI, J. B., & Handberg, E. M. (2004) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200407000-00001 · Cited by 20
Ricci, R. P., Pignalberi, C., Landolina, M., Santini, M., Lunati, M., Boriani, G., Proclemer, A., Facchin, D., Catanzariti, D., Morani, G., et al. (2014) · Heart · doi:10.1136/heartjnl-2013-305259 · Cited by 20
Bundgaard, J. S., Thune, J. J., Nielsen, J. C., Videbæk, R., Haarbo, J., Bruun, N. E., Videbæk, L. M., Aagaard, D., Korup, E., Jensen, G. V. H., et al. (2019) · EP Europace · doi:10.1093/europace/euz018 · Cited by 19
ICD Therapy in Children and Young Adults: Low Incidence of Inappropriate Shock Delivery
BOTSCH, M. P., Franzbach, B., Opgen‐Rhein, B., Berger, F. F., & Will, J. C. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02695.x · Cited by 19
Donahue, R. G., Lampert, R. J., Dornelas, E. A., Clemow, L., & Burg, M. M. (2009) · Psychosomatic Medicine · doi:10.1097/psy.0b013e3181c932d4 · Cited by 19
Antiarrhythmic Drug Therapy to Avoid Implantable Cardioverter Defibrillator Shocks
Abboud, J., & Ehrlich, J. R. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.10.2 · Cited by 19
Radiotherapy for ablation of ventricular tachycardia: Assessing collateral dosing
John, R. M., Shinohara, E. T., Price, M., & Stevenson, W. G. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.08.010 · Cited by 19
Wong, F. M. F., Sit, J. W. H., Wong, E. M. L., & Choi, K. C. (2014) · Journal of Advanced Nursing · doi:10.1111/jan.12434 · Cited by 19
Outcomes of elderly heart failure recipients of ICD and CRT
Grimm, W. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.10.007 · Cited by 19
Boriani, G., Biffi, M., Silvestri, P., Martignani, C., Valzania, C., Diemberger, I., Moulder, C., MOUCHAWAR, G. A., Kroll, M. W., & Branzi, A. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.03.024 · Cited by 19
Antezano, E. S., & Hong, M. F. (2003) · Journal of Intensive Care Medicine · doi:10.1177/0885066603258140 · Cited by 19
Implantable Cardioverter-Defibrillators: Clinical Aspects
Swerdlow, C. D., & Shivkumar, K. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50110-x · Cited by 19
Stereotactic ablative radiotherapy in patients with refractory ventricular tachyarrhythmia
Molon, G., Giaj‐Levra, N., Costa, A., Bonapace, S., Cuccia, F., Marinelli, A., Trachanas, K., Sicignano, G., & Alongi, F. (2022) · European Heart Journal Supplements · doi:10.1093/eurheartj/suac016 · Cited by 18
Athletes with Implantable Cardioverter Defibrillators
Ponamgi, S., DeSimone, C. V., & Ackerman, M. J. (2015) · Clinics in Sports Medicine · doi:10.1016/j.csm.2015.03.010 · Cited by 18
Yang, J. H., Byeon, K., Yim, H. R., Park, J. W., Park, S., Huh, J., Kim, J. S., & On, Y. K. (2012) · Journal of Korean Medical Science · doi:10.3346/jkms.2012.27.6.619 · Cited by 18
Darma, A., Bertagnolli, L., Weber, A., Dinov, B., Torri, F., Lurz, J. A., Shamloo, A. S., Dagres, N., Bollmann, A., Hindricks, G., et al. (2021) · EP Europace · doi:10.1093/europace/euab194 · Cited by 18
Baumert, J. J., Schmitt, C., & Ladwig, K. (2006) · Psychosomatic Medicine · doi:10.1097/01.psy.0000221379.17371.47 · Cited by 18
Wong, F. M. F. (2016) · Journal of Clinical Nursing · doi:10.1111/jocn.13637 · Cited by 18
Silver, M. T., Sterns, L. D., Piccini, J. P., Joung, B., Ching, C., Pickett, R. A., Rabinovich, R. F., Liu, S., Peterson, B. J., & Lexcen, D. R. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.11.002 · Cited by 17
Kajanová, A., Bulava, A., & Eisenberger, M. (2014) · PubMed · Cited by 17
Should Catheter Ablation be the Preferred Therapy for Reducing ICD Shocks?
Kück, K. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.896571 · Cited by 18
Schuger, C. D., Daubert, J. P., Zaręba, W., Rosero, S. Z., Yong, P., McNitt, S. A., & Kutyifa, V. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.11.019 · Cited by 17
The effect of cardiac genetic testing on psychological well-being and illness perceptions
Hickey, K. T., Sciacca, R. R., BIVIANO, A. B., Whang, W., Dizon, J. M., Garan, H., & Chung, W. K. (2014) · Heart & Lung · doi:10.1016/j.hrtlng.2014.01.006 · Cited by 17
Combining Resynchronization and Defibrillation Therapies for Heart Failure
Bradley, D. J. (2003) · JAMA · doi:10.1001/jama.289.20.2719 · Cited by 17
Kim, J., Pressler, S. J., & Groh, W. J. (2013) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0b013e31829dfc6e · Cited by 16
da Silva, G. L., Nunes-Ferreira, A., Cortez‐Dias, N., de Sousa, J., Pinto, F. J., & Caldeira, D. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00870-3 · Cited by 16
França, A. T., Martins, L. N. A., Oliveira, D. M., de Castilho, F. M., Castello-Branco, B., Wilnes, B., Ribeiro, A. L. P., & do Carmo, A. A. L. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16201 · Cited by 16
Radiofrequency Catheter Ablation for Ventricular Tachycardia
Haqqani, H. M., & Roberts‐Thomson, K. C. (2012) · Heart Lung and Circulation · doi:10.1016/j.hlc.2011.10.015 · Cited by 16
Jayam, V., Zviman, M. M., Jayanti, V. B., Roguin, A., Halperin, H. R., & Berger, R. D. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.06.030 · Cited by 16
Nuclear Imaging Guidance for Ablation of Ventricular Arrhythmias
Duell, J., Dilsizian, V., Smith, M. F., Chen, W., & Dickfeld, T. M. (2016) · Current Cardiology Reports · doi:10.1007/s11886-015-0697-2 · Cited by 16
Dilaveris, P., Antoniou, C. K., & Gatzoulis, K. A. (2017) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.06.003 · Cited by 16
Exner, D. V. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124051 · Cited by 16
Self-citationAlmendral, J. M., & Josephson, M. E. (2007) · Circulation · doi:10.1161/circulationaha.106.670067 · Cited by 16
Cozzi, S., Bottoni, N., Botti, A., Trojani, V., Alì, E., Ghersi, S. F., Cremaschi, F., Iori, F., Ciammella, P., Iori, M., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12111783 · Cited by 15
Metadata
- Authors
- Schron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., Powell, J., & the AVID Investigators
- Affiliations
- University of Maryland, Baltimore (US)
- Venue
- Circulation
- Published
- 2002-02-05
- Volume
- 105
- Issue
- 5
- Pages
- 589-594
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2101541776
- Semantic Scholar
- 216ffa4eb6d0222f0b0b6ea03afb7c4d6d95a1c3
- Cited by
- 624
- References
- 39
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 16 · 2022: 14 · 2021: 26 · 2020: 19 · 2019: 26 · 2018: 17 · 2017: 27 · 2016: 31 · 2015: 36 · 2014: 24 · 2013: 27 · 2012: 39
- FWCI
- 13.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Fondation pour la Recherche Médicale
- National Institutes of Health (n01hc025117-014)
- Canadian Institutes of Health Research
- National Heart, Lung, and Blood Institute (N01-HC-25117)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- quality of life, implantable cardioverter-defibrillator, antiarrhythmic drugs, ventricular arrhythmias, ICD shocks, adverse symptoms, physical function, psychological well-being, patient concerns
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Demography, Electric Countershock, Electrocardiography, Female, Humans, Male, Middle Aged, Quality of Life, Surveys and Questionnaires, Treatment Outcome, Defibrillators, Implantable
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review