Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 470

The DOI matches its Crossref record.

Local Delivery of Plasmid DNA Into Rat Carotid Artery Using Ultrasound

Taniyama, Yoshiaki, Tachibana, Katsuro, Hiraoka, Kazuya, Namba, Tsunetatsu, Yamasaki, Keita, Hashiya, Naotaka, Aoki, Motokuni, Ogihara, Toshio, Yasufumi, Kaneda, Morishita, Ryuichi·2002·Circulation

Abstract

Background — Although viral vector systems are efficient to transfect foreign genes into blood vessels, safety issues remain in relation to human gene therapy. In this study, we examined the feasibility of a novel nonviral vector system by using high-frequency, low-intensity ultrasound irradiation for transfection into blood vessels. Methods and Results — Luciferase plasmid mixed with or without echo contrast microbubble (Optison) was transfected into cultured human vascular smooth muscle cells (VSMC) and endothelial cells (EC) with the use of ultrasound. Interestingly, luciferase activity was markedly increased in both cell types treated with Optison. We then transfected luciferase plasmid mixed with Optison by means of therapeutic ultrasound into rat artery. Two days after transfection, luciferase activity was significantly higher in carotid artery transfected with luciferase gene with Optison and ultrasound than with plasmid alone. In addition, we transfected an anti-oncogene (p53) plasmid into carotid artery after balloon injury as a model of gene therapy for restenosis. Two weeks after transfection, the intimal-to-medial area ratio in rats transfected with wild-type p53 plasmid complexed with Optison by means of ultrasound was significantly decreased as compared with control, accompanied by a significant increase in p53 protein. No apparent toxicity such as inflammation could be detected in blood vessels transfected with plasmid DNA with ultrasound and Optison. Conclusions — Overall, we demonstrated that an ultrasound transfection method with Optison enhanced transfection efficiency of naked plasmid DNA into blood vessels without any apparent toxicity. Transfection of p53 plasmid with the use of this method should be useful for safe clinical gene therapy without a viral vector system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc1002.105228

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 470

Metadata

Authors
Taniyama, Y., Tachibana, K., Hiraoka, K., Namba, T., Yamasaki, K., Hashiya, N., Aoki, M., Ogihara, T., Yasufumi, K., & Morishita, R.
Venue
Circulation
Published
2002-03-12
Volume
105
Issue
10
Pages
1233-1239
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2061360046
Cited by
470
References
0
FWCI
27.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Local Delivery of Plasmid DNA Into Rat Carotid Artery Using Ultrasound. https://app.cochat.ai/papers/10.1161/hc1002.105228
The paper
Taniyama, Y., Tachibana, K., Hiraoka, K., Namba, T., Yamasaki, K., Hashiya, N., Aoki, M., Ogihara, T., Yasufumi, K., & Morishita, R. (2002). Local Delivery of Plasmid DNA Into Rat Carotid Artery Using Ultrasound. Circulation. https://doi.org/10.1161/hc1002.105228

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.