The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Local Delivery of Plasmid DNA Into Rat Carotid Artery Using Ultrasound
Abstract
Background — Although viral vector systems are efficient to transfect foreign genes into blood vessels, safety issues remain in relation to human gene therapy. In this study, we examined the feasibility of a novel nonviral vector system by using high-frequency, low-intensity ultrasound irradiation for transfection into blood vessels. Methods and Results — Luciferase plasmid mixed with or without echo contrast microbubble (Optison) was transfected into cultured human vascular smooth muscle cells (VSMC) and endothelial cells (EC) with the use of ultrasound. Interestingly, luciferase activity was markedly increased in both cell types treated with Optison. We then transfected luciferase plasmid mixed with Optison by means of therapeutic ultrasound into rat artery. Two days after transfection, luciferase activity was significantly higher in carotid artery transfected with luciferase gene with Optison and ultrasound than with plasmid alone. In addition, we transfected an anti-oncogene (p53) plasmid into carotid artery after balloon injury as a model of gene therapy for restenosis. Two weeks after transfection, the intimal-to-medial area ratio in rats transfected with wild-type p53 plasmid complexed with Optison by means of ultrasound was significantly decreased as compared with control, accompanied by a significant increase in p53 protein. No apparent toxicity such as inflammation could be detected in blood vessels transfected with plasmid DNA with ultrasound and Optison. Conclusions — Overall, we demonstrated that an ultrasound transfection method with Optison enhanced transfection efficiency of naked plasmid DNA into blood vessels without any apparent toxicity. Transfection of p53 plasmid with the use of this method should be useful for safe clinical gene therapy without a viral vector system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
von der Leyen, H. E., Gibbons, G. H., Morishita, R., Lewis, N. P., Zhang, L., Nakajima, M., Kaneda, Y., Cooke, J. P., & Dzau, V. J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.4.1137 · Cited by 762
Self-citationGene Therapy Death Prompts Review of Adenovirus Vector
Marshall, E. (1999) · Science · doi:10.1126/science.286.5448.2244 · Cited by 760
Morishita, R., Gibbons, G. H., Horiuchi, M., Ellison, K. E., Nakama, M., Zhang, L., Kaneda, Y., Ogihara, T., & Dzau, V. J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.13.5855 · Cited by 479
Self-citationMorishita, R., Gibbons, G. H., Ellison, K. E., Nakajima, M., Zhang, L., Kaneda, Y., Ogihara, T., & Dzau, V. J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.18.8474 · Cited by 458
Self-citationInduction of cell-membrane porosity by ultrasound
Tachibana, K., Uchida, T., Ogawa, K., Yamashita, N., & Tamura, K. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01244-1 · Cited by 449
Self-citationChang, M. W., Barr, E., Seltzer, J., Jiang, Y.-Q., Nabel, G. J., Nabel, E. G., Parmacek, M. S., & Leiden, J. M. (1995) · Science · doi:10.1126/science.7824950 · Cited by 446
A cascade model for restenosis. A special case of atherosclerosis progression.
Libby, P., Schwartz, D., Brogi, E., Tanaka, H., & Clinton, S. K. (1992) · PubMed · Cited by 437
Albumin Microbubble Echo-Contrast Material as an Enhancer for Ultrasound Accelerated Thrombolysis
Tachibana, K., & Tachibana, S. (1995) · Circulation · doi:10.1161/01.cir.92.5.1148 · Cited by 343
Self-citationMyocardial viability in patients with Q wave myocardial infarction and no residual ischemia.
Montalescot, G., Faraggi, M., Drobinski, G., Messian, O., Evans, J., Grosgogeat, Y., & Thomas, D. (1992) · Circulation · doi:10.1161/01.cir.86.1.47 · Cited by 276
Lemarchand, P., Jones, M., Yamada, I., & Crystal, R. G. (1993) · Circulation Research · doi:10.1161/01.res.72.5.1132 · Cited by 257
Cited by
Ultrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Healing sound: the use of ultrasound in drug delivery and other therapeutic applications
Mitragotri, S. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1662 · Cited by 980
Gene Therapy Progress and Prospects: Nonviral vectors
Niidome, T., & Huang, L. (2002) · Gene Therapy · doi:10.1038/sj.gt.3301923 · Cited by 963
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Sheikov, N., McDannold, N., Vykhodtseva, N., Jolesz, F., & Hynynen, K. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.04.010 · Cited by 617
Vibrating microbubbles poking individual cells: Drug transfer into cells via sonoporation
van Wamel, A., Kooiman, K., Harteveld, M., Emmer, M., ten Cate, F. J., Versluis, M., & de Jong, N. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.02.007 · Cited by 595
Therapeutic applications of lipid-coated microbubbles
Unger, E. C., Porter, T., Culp, W., Labell, R., Matsunaga, T., & Zutshi, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.12.006 · Cited by 591
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Meijering, B. D. M., Juffermans, L. J. M., van Wamel, A., Henning, R. H., Zuhorn, I. S., Emmer, M., Versteilen, A. M. G., Paulus, W. J., van Gilst, W. H., Kooiman, K., et al. (2009) · Circulation Research · doi:10.1161/circresaha.108.183806 · Cited by 483
Micelles and nanoparticles for ultrasonic drug and gene delivery
Husseini, G. A., & Pitt, W. G. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.008 · Cited by 468
Gene therapy and DNA delivery systems
Ibraheem, D., Elaissari, A., & Fessi, H. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.11.041 · Cited by 454
Rapoport, N., Nam, K.-H., Gupta, R., Gao, Z., Mohan, P., Payne, A., Todd, N., Liu, X., Kim, T., Shea, J., et al. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.022 · Cited by 423
High-Intensity Focused Ultrasound: Current Potential and Oncologic Applications
Dubinsky, T. J., Cuevas, C., Dighe, M. K., Kolokythas, O., & Hwang, J. H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2671 · Cited by 420
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Physical methods for gene transfer: Improving the kinetics of gene delivery into cells
MEHIERHUMBERT, S., & GUY, R. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.12.007 · Cited by 395
Gene Therapy Progress and Prospects: Electroporation and other physical methods
Wells, D. J. (2004) · Gene Therapy · doi:10.1038/sj.gt.3302337 · Cited by 372
Karshafian, R., Bevan, P. D., Williams, R., Samac, S., & Burns, P. N. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.10.013 · Cited by 355
Lan, H. Y., Mu, W., Tomita, N., Huang, X. R., Li, J. H., Zhu, H.-J., Morishita, R., & Johnson, R. J. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000067632.04658.b8 · Cited by 344
Self-citationLiposomes in ultrasonic drug and gene delivery
Huang, S.-L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.003 · Cited by 339
Sinn, P. L., Sauter, S. L., & McCray, P. B. (2005) · Gene Therapy · doi:10.1038/sj.gt.3302570 · Cited by 322
Ultrasound-induced encapsulated microbubble phenomena
Postema, M., van Wamel, A., Lancée, C. T., & de Jong, N. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.02.010 · Cited by 275
Targeted tissue transfection with ultrasound destruction of plasmid-bearing cationic microbubbles
Christiansen, J. P., French, B. A., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00976-1 · Cited by 273
Zhang, Y., Huang, X.-R., Wei, L.-H., Chung, A. C., Yu, C.-M., & Lan, H.-Y. (2014) · Molecular Therapy · doi:10.1038/mt.2014.25 · Cited by 271
RetractedUltrasonically triggered drug delivery: Breaking the barrier
Husseini, G. A., Pitt, W. G., & Martins, A. M. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.07.051 · Cited by 87
Microbubbles as a novel contrast agent for brain MRI
Cheung, J. S., Chow, A. M., Guo, H., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.037 · Cited by 36
Metadata
- Authors
- Taniyama, Y., Tachibana, K., Hiraoka, K., Namba, T., Yamasaki, K., Hashiya, N., Aoki, M., Ogihara, T., Yasufumi, K., & Morishita, R.
- Venue
- Circulation
- Published
- 2002-03-12
- Volume
- 105
- Issue
- 10
- Pages
- 1233-1239
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2061360046
- Cited by
- 470
- References
- 29
- FWCI
- 27.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.