The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Atrial Therapies Reduce Atrial Arrhythmia Burden in Defibrillator Patients
Open accessAbstract
Background Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. Methods and Results Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies “on” or “off” and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had ≥30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant ( P =0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted ( P =0.01). Conclusions In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339
Friedman, P. A., Luria, D., Fenton, A. M., Munger, T. M., Jahangir, A., Shen, W. K., Rea, R. F., Stanton, M. S., Hammill, S. C., & Packer, D. L. (2000) · Circulation · doi:10.1161/01.cir.101.13.1568 · Cited by 117
Self-citation
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationZipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Management of atrial fibrillation
Lip, G. Y., & Tse, H.-F. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61300-2 · Cited by 229
Metadata
- Authors
- Friedman, P. A., Dijkman, B., Warman, E. N., Xia, H. A., Mehra, R., Stanton, M. S., Hammill, S. C., & for the Worldwide Jewel AF Investigators
- Venue
- Circulation
- Published
- 2001-08-28
- Volume
- 104
- Issue
- 9
- Pages
- 1023-1028
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2122983335
- Cited by
- 160
- References
- 2
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial Therapies Reduce Atrial Arrhythmia Burden in Defibrillator Patients. https://app.cochat.ai/papers/10.1161/hc3401.095039
- The paper
- Friedman, P. A., Dijkman, B., Warman, E. N., Xia, H. A., Mehra, R., Stanton, M. S., Hammill, S. C., & for the Worldwide Jewel AF Investigators. (2001). Atrial Therapies Reduce Atrial Arrhythmia Burden in Defibrillator Patients. Circulation. https://doi.org/10.1161/hc3401.095039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.