Cited by 229Atrial Fibrillation Management and OutcomesAcute Ischemic Stroke ManagementCardiac Arrhythmias and Treatments

Management of atrial fibrillation

Lip, Gregory YH, Tse, Hung-Fat·2007·The Lancet

Abstract

Atrial fibrillation is the most common sustained cardiac rhythm disorder, and confers a substantial mortality and morbidity from stroke, thromboembolism, heart failure, and impaired quality of life. With the increasingly elderly population in the developed world, as well as improvements in the management of myocardial infarction and heart failure, the prevalence of atrial fibrillation is increasing, resulting in a major public-health problem. This Review aims to provide an overview on the modern management of atrial fibrillation, with particular emphasis on pharmacological and non-pharmacological approaches. Irrespective of a rate-control or rhythm-control strategy, stroke prevention with appropriate thromboprophylaxis still remains central to the management of this common arrhythmia. Electrophysiological approaches could hold some promise for a curative approach in atrial fibrillation.

Integrity signals

Registry

Crossref · 10.1016/s0140-6736(07)61300-2

Cites

128 of 128 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • AFib is the leading cause of death and morbidity due to stroke, heart failure, thromboembolism, and reduced quality of life, and accounts for the majority of these cases.

    “AFib is the leading cause of death and morbidity due to stroke, heart failure, thromboembolism, and reduced quality of life, and accounts for the majority of these cases [127].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lip, G. Y., & Tse, H.-F.
Affiliations
  • Birmingham City Hospital (GB)
  • University of Hong Kong (HK)
Corresponding author
Lip, Gregory YH
Venue
The Lancet
Publisher
Elsevier BV
Published
2007-08
Volume
370
Issue
9587
Pages
604-618
ISSN
  • 0099-5355 (ISSN-L)
  • 0140-6736
OpenAlex
W2103751952
Cited by
229
References
128
Citations by year
2026: 5 · 2025: 14 · 2024: 12 · 2023: 10 · 2022: 10 · 2021: 10 · 2020: 6 · 2019: 6 · 2018: 9 · 2017: 11 · 2016: 7 · 2015: 9 · 2014: 11 · 2013: 13 · 2012: 18
FWCI
3.00
Type
journal article
Language
en
Open access
closed
Locations
  • The Lancet (publishedVersion)
  • PubMed (publishedVersion)
  • The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Epidemiology › Acute Ischemic Stroke Management
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
atrial fibrillation, stroke prevention, thromboembolism, anticoagulation, rate control, rhythm control, antiarrhythmic drugs, catheter ablation, heart failure, arrhythmia management
MeSH terms
Algorithms, Anti-Arrhythmia Agents, Atrial Fibrillation, Electric Countershock, Fibrinolytic Agents, Humans, Pacemaker, Artificial, Risk Factors, Catheter Ablation, Defibrillators, Implantable, Practice Guidelines as Topic, Stroke

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review