Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 251

The DOI matches its Crossref record.

Imaging Time After Gd-DTPA Injection Is Critical in Using Delayed Enhancement to Determine Infarct Size Accurately With Magnetic Resonance Imaging

Oshinski, John N., Yang, Zequan, Jones, Jeffrey R., Mata, Jaime F., French, Brent A. · 2001 · Circulation

Abstract

Background In patients with acute myocardial infarction (MI), delayed enhancement is seen in MRI 5 to 7 minutes after gadolinium–diethylenetriamine pentaacetic acid (Gd-DTPA) injection, and the enhancement occurs in regions that later show recovery of function. However, in a canine model of acute MI, delayed enhancement 20 to 30 minutes after injection only occurs in necrotic regions and not in surrounding, reversibly injured myocardium. The objective of the present study was to determine (1) if the size of the enhanced region varies with time after Gd-DTPA injection and (2) if and when the size of the enhanced region corresponds to the true infarct size. Methods and Results The left coronary artery was occluded in 15 Lewis rats for 30 minutes (n=9) or 2 hours (n=6); this was followed by reperfusion. MRI scans were performed 48±2 hours after-MI. Midventricular short-axis images were obtained continuously for 40 minutes after Gd-DTPA injection (0.3 mmol/kg). The sizes of enhanced regions at each time were determined by threshold analysis and compared with triphenyltetrazolium chloride–stained sections of the excised rat heart. In all animals, the enhanced region overestimated infarct size (28±5%) immediately after the injection of Gd-DTPA, although it then gradually receded to match the size of the infarct. The time required for enhancement to accurately determine infarct size was significantly different between 2-hour infarcts (16±2 minutes) and 30-minute (26±4 minutes) infarcts ( P <0.05). Conclusions In reperfused acute MI, accurate determination of infarct size by delayed enhancement MRI requires imaging at specific times after Gd-DTPA injection, and this time varies with the duration of occlusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc4801.100351

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
Oshinski, J. N., Yang, Z., Jones, J. R., Mata, J. F., & French, B. A.
Venue
Circulation
Published
2001-12-04
Volume
104
Issue
23
Pages
2838-2842
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2113507421
Cited by
251
References
0
FWCI
12.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging Time After Gd-DTPA Injection Is Critical in Using Delayed Enhancement to Determine Infarct Size Accurately With Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/hc4801.100351
The paper
Oshinski, J. N., Yang, Z., Jones, J. R., Mata, J. F., & French, B. A. (2001). Imaging Time After Gd-DTPA Injection Is Critical in Using Delayed Enhancement to Determine Infarct Size Accurately With Magnetic Resonance Imaging. Circulation. https://doi.org/10.1161/hc4801.100351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.