Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 336

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Detection of Pulmonary Vein and Left Atrial Scar after Catheter Ablation with Three-dimensional Navigator-gated Delayed Enhancement MR Imaging: Initial Experience1

Peters, Dana C., Wylie, John V., Hauser, Thomas H., Kissinger, Kraig V., Botnar, René M., Essebag, Vidal, Josephson, Mark E., Manning, Warren J. · 2007 · Radiology

Abstract

PURPOSE: To prospectively evaluate whether scar caused by radiofrequency (RF) ablation of the left atrium (LA) in patients with atrial fibrillation can be depicted with high-spatial-resolution delayed enhancement magnetic resonance (MR) imaging. MATERIALS AND METHODS: All 23 subjects (16 men, seven women; mean age, 54 years +/- 13 [standard deviation]) provided written informed consent; the study was approved by the local institutional review board and was HIPAA compliant. A high-spatial-resolution free-breathing delayed enhancement MR imaging method was developed to detect scar (ie, ablated tissue) in the LA and pulmonary veins (PVs). The LA in 15 patients before ablation and in 18 patients at least 30 days after ablation was examined. A reader with 4 years of experience assessed presence of delayed enhancement on images and circumferential completeness. Signal-to-noise and contrast-to-noise ratios were measured and compared with an unpaired t test. The relationship between measurements of enhancement thickness at the interatrial septum and the number of days after ablation was investigated. RESULTS: No subject demonstrated preablation delayed enhancement of the atrial or PV wall, whereas postablation delayed enhancement was identified in all (100%). In patients after ablation, a partial to completely circumferential delayed enhancement pattern could be identified for the left inferior PV that encompassed 88% +/- 11 of the circumference, but only 62% of patients demonstrated more than 90% circumferential delayed enhancement. The signal-to-noise ratio of blood was 12, and the signal-to-noise ratios of the pre- and postablation left atrial wall were 15 and 22, respectively (P<.05). A relationship between delayed enhancement wall thickness and the inverse of the time interval from ablation was identified (P<.05). CONCLUSION: High-spatial-resolution delayed enhancement MR imaging allows noninvasive identification of scar induced by RF ablation following isolation therapy of the PV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2433060417

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 336

Metadata

Authors
Peters, D. C., Wylie, J. V., Hauser, T. H., Kissinger, K. V., Botnar, R. M., Essebag, V., Josephson, M. E., & Manning, W. J.
Venue
Radiology
Published
2007-06
Volume
243
Issue
3
Pages
690-695
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2156011709
Cited by
336
References
28
FWCI
15.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Pulmonary Vein and Left Atrial Scar after Catheter Ablation with Three-dimensional Navigator-gated Delayed Enhancement MR Imaging: Initial Experience1. https://app.cochat.ai/papers/10.1148/radiol.2433060417
The paper
Peters, D. C., Wylie, J. V., Hauser, T. H., Kissinger, K. V., Botnar, R. M., Essebag, V., Josephson, M. E., & Manning, W. J. (2007). Detection of Pulmonary Vein and Left Atrial Scar after Catheter Ablation with Three-dimensional Navigator-gated Delayed Enhancement MR Imaging: Initial Experience1. Radiology. https://doi.org/10.1148/radiol.2433060417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.