The DOI matches its Crossref record.
Effect of Resynchronization Therapy Stimulation Site on the Systolic Function of Heart Failure Patients
Open accessAbstract
Background — Cardiac resynchronization therapy (CRT) improves systolic function in heart failure patients with ventricular conduction delay by stimulating the left ventricle (LV) or both ventricles (biventricular, BV). Optimal LV site selection is of major clinical interest for CRT device implantation; however, the dependence of hemodynamics on LV stimulation site has not been established. Thus, the objective of this study was to compare the hemodynamic response to CRT for 2 LV coronary vein sites: the free wall and anterior wall. Methods and Results — A total of 30 patients (mean NYHA class, 2.7; mean QRS interval, 152 ms; mean PR interval, 194 ms) enrolled in the PATH-CHF-II trial were studied. CRT was administered with LV and BV stimulation in VDD mode at 4 AV delays. LV stimulation was at the lateral free wall or anterior wall, whereas right ventricular stimulation was fixed near the apex. LV+dP/dt max and aortic pulse pressure changes from baseline during CRT were compared for LV sites. Free wall sites with LV and BV stimulation yielded significantly larger LV+dP/dt max (14% versus 6%, P <0.001 for LV; 12% versus 5%, P <0.001 for BV) and pulse pressure (8% versus 4%, P <0.001 for LV; 9% versus 5%, P <0.001 for BV) compared with anterior sites. In one third of patients, CRT at free wall sites increased LV+dP/dt max , whereas it decreased at anterior sites over most AV delays. Conclusion — CRT with LV free wall stimulation produced significantly better LV systolic performance compared with anterior stimulation. Further studies are warranted to prove the clinical superiority of the LV free wall as a site for long-term CRT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Daubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
Self-citationWhite, J. A., Yee, R., Yuan, X., Krahn, A., Skanes, A., Parker, M., Klein, G., & Drangova, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.046 · Cited by 386
Ypenburg, C., van Bommel, R. J., Delgado, V., Mollema, S. A., Bleeker, G. B., Boersma, E., Schalij, M. J., & Bax, J. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.046 · Cited by 379
Kindermann, M., Hennen, B., Jung, J., Geisel, J., Böhm, M., & Fröhlig, G. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.056 · Cited by 278
Kristiansen, H. M., Hovstad, T., Vollan, G., & Faerestrand, S. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30458-2 · Cited by 5
Metadata
- Authors
- Butter, C., Auricchio, A., Stellbrink, C., Fleck, E., Ding, J., Yu, Y., Huvelle, E., & Spinelli, J.
- Venue
- Circulation
- Published
- 2001-12-17
- Volume
- 104
- Issue
- 25
- Pages
- 3026-3029
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2159318323
- Cited by
- 621
- References
- 0
- FWCI
- 19.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Resynchronization Therapy Stimulation Site on the Systolic Function of Heart Failure Patients. https://app.cochat.ai/papers/10.1161/hc5001.102229
- The paper
- Butter, C., Auricchio, A., Stellbrink, C., Fleck, E., Ding, J., Yu, Y., Huvelle, E., & Spinelli, J. (2001). Effect of Resynchronization Therapy Stimulation Site on the Systolic Function of Heart Failure Patients. Circulation. https://doi.org/10.1161/hc5001.102229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.