Cerebral Protection During Carotid Artery Stenting: Collection and Histopathologic Analysis of Embolized Debris
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background and Purpose — Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. Methods — Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery presenting >70% diameter stenosis (mean, 82.1±11.1%). Mean age of the patients was 70.7±7.7 years; 75% were men, and 50% of patients had previous neurological symptoms. Results — In 37 lesions (97.4%) it was possible to position the filter device, and in all lesions a stent was successfully implanted. The only complication occurring in the hospital and during the 30-day follow-up was 1 death due to acute myocardial infarction. Neurological sequelae did not occur. Histomorphometric analysis was performed on the filters. Presence of debris was detected in 83.7% of filters. The mean surface area of the polyurethane membrane filter covered with material was 53.2±19.8%. Particle size ranged from 1.08 to 5043.5 μm (mean, 289.5±512 μm) in the major axis and 0.7 to 1175.3 μm (mean, 119.7±186.7 μm) in the minor axis. Collected debris consisted predominantly of thrombotic material, foam cells, and cholesterol clefts. Conclusions — By the use of distal protection filters during carotid artery stenting, it was possible to collect particulate debris potentially leading to distal vessel occlusion in a high percentage of cases. Qualitative analysis of embolized material showed debris dislocated during the percutaneous intervention from atheromatous plaques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Cited by
Kastrup, A., Gröschel, K., Krapf, H., Brehm, B. R., Dichgans, J., & Schulz, J. B. (2003) · Stroke · doi:10.1161/01.str.0000058160.53040.5f · Cited by 567
Brooks, W. H., McClure, R. R., Jones, M. R., Coleman, T. L., & Breathitt, L. (2004) · Neurosurgery · doi:10.1227/01.neu.0000103447.30087.d3 · Cited by 232
“Indeed, costs and charges may increase in the future if the use of distal protection devices becomes an integral component required for successful, uncomplicated CAS (4, 56, 59).”
BackgroundReimers, B., Schlüter, M., Castriota, F., Tübler, T., Corvaja, N., Cernetti, C., Manetti, R., Picciolo, A., Liistro, F., Mario, C. D., et al. (2004) · The American Journal of Medicine · doi:10.1016/j.amjmed.2003.09.043 · Cited by 167
Self-citation
Metadata
- Authors
- Angelini, A., Reimers, B., Barbera, M. D., Saccà, S., Pasquetto, G., Cernetti, C., Valente, M., Pascotto, P., & Thiene, G.
- Venue
- Stroke
- Published
- 2002-02
- Volume
- 33
- Issue
- 2
- Pages
- 456-461
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2119070826
- Cited by
- 176
- References
- 1
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral Protection During Carotid Artery Stenting: Collection and Histopathologic Analysis of Embolized Debris. https://app.cochat.ai/papers/10.1161/hs0202.102337
- The paper
- Angelini, A., Reimers, B., Barbera, M. D., Saccà, S., Pasquetto, G., Cernetti, C., Valente, M., Pascotto, P., & Thiene, G. (2002). Cerebral Protection During Carotid Artery Stenting: Collection and Histopathologic Analysis of Embolized Debris. Stroke. https://doi.org/10.1161/hs0202.102337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.