Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record.

Pulsatile Hemodynamics in Congestive Heart Failure

Mitchell, Gary F., Tardif, Jean-Claude, Arnold, J. Malcolm O., Marchiori, Gordon, O’Brien, Terrence X., Dunlap, Mark E., Pfeffer, Marc A. · 2001 · Hypertension

Abstract

Pulse pressure, an indirect measure of vascular stiffness and pulsatile load, predicts clinical events in congestive heart failure (CHF), suggesting that abnormal pulsatile load may contribute to CHF. This study was designed to assess more direct measures of central pulsatile load in CHF. Noninvasive hemodynamic evaluations were performed in 28 subjects with CHF and 40 controls using calibrated tonometry of the brachial, radial, femoral, and carotid arteries along with echocardiographic assessment of left ventricular outflow tract (LVOT) diameter and Doppler flow. Characteristic impedance (Z c ) was calculated as the ratio of ΔP (carotid) and ΔQ (LVOT flow) in early systole. Carotid-radial (CR-PWV) and carotid-femoral (CF-PWV) pulse wave velocities were calculated from tonometry. Augmentation index was assessed from the carotid waveform. Total arterial compliance (TAC) was calculated using the area method. Brachial pulse pressure was elevated (62±16 versus 53±15 mm Hg, P =0.015) in CHF because of lower diastolic pressure (66±10 versus 73±9 mm Hg, P =0.003). CHF had higher Z c (225±76 versus 184±66 dyne · sec · cm −5 , P =0.020). CF-PWV did not differ (9.7±2.7 versus 9.2±2.0, P =0.337), whereas CR-PWV was lower in CHF (8.6±1.4 versus 9.4±1.5, P =0.038). There was no difference in TAC (1.4±0.5 versus 1.4±0.6 mL/mmHg, P =0.685), and augmentation index was lower in CHF (8±17 versus 21±13%, P =0.001). CHF subjects have elevated central pulsatile load (Z c ), which is not apparent in global measures such as augmentation index or TAC, possibly because of contrasting changes in central and peripheral conduit vessels. This increased pulsatile load represents an important therapeutic target in CHF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hy1201.098298

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Mitchell, G. F., Tardif, J.-C., Arnold, J. M. O., Marchiori, G., O’Brien, T. X., Dunlap, M. E., & Pfeffer, M. A.
Venue
Hypertension
Published
2001-12
Volume
38
Issue
6
Pages
1433-1439
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2160845309
Cited by
203
References
0
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulsatile Hemodynamics in Congestive Heart Failure. https://app.cochat.ai/papers/10.1161/hy1201.098298
The paper
Mitchell, G. F., Tardif, J.-C., Arnold, J. M. O., Marchiori, G., O’Brien, T. X., Dunlap, M. E., & Pfeffer, M. A. (2001). Pulsatile Hemodynamics in Congestive Heart Failure. Hypertension. https://doi.org/10.1161/hy1201.098298

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.