The DOI matches its Crossref record.
Pulsatile Hemodynamics in Congestive Heart Failure
Abstract
Pulse pressure, an indirect measure of vascular stiffness and pulsatile load, predicts clinical events in congestive heart failure (CHF), suggesting that abnormal pulsatile load may contribute to CHF. This study was designed to assess more direct measures of central pulsatile load in CHF. Noninvasive hemodynamic evaluations were performed in 28 subjects with CHF and 40 controls using calibrated tonometry of the brachial, radial, femoral, and carotid arteries along with echocardiographic assessment of left ventricular outflow tract (LVOT) diameter and Doppler flow. Characteristic impedance (Z c ) was calculated as the ratio of ΔP (carotid) and ΔQ (LVOT flow) in early systole. Carotid-radial (CR-PWV) and carotid-femoral (CF-PWV) pulse wave velocities were calculated from tonometry. Augmentation index was assessed from the carotid waveform. Total arterial compliance (TAC) was calculated using the area method. Brachial pulse pressure was elevated (62±16 versus 53±15 mm Hg, P =0.015) in CHF because of lower diastolic pressure (66±10 versus 73±9 mm Hg, P =0.003). CHF had higher Z c (225±76 versus 184±66 dyne · sec · cm −5 , P =0.020). CF-PWV did not differ (9.7±2.7 versus 9.2±2.0, P =0.337), whereas CR-PWV was lower in CHF (8.6±1.4 versus 9.4±1.5, P =0.038). There was no difference in TAC (1.4±0.5 versus 1.4±0.6 mL/mmHg, P =0.685), and augmentation index was lower in CHF (8±17 versus 21±13%, P =0.001). CHF subjects have elevated central pulsatile load (Z c ), which is not apparent in global measures such as augmentation index or TAC, possibly because of contrasting changes in central and peripheral conduit vessels. This increased pulsatile load represents an important therapeutic target in CHF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Self-citationSafar, M. E., Levy, B. I., & Struijker-Boudier, H. (2003) · Circulation · doi:10.1161/01.cir.0000069826.36125.b4 · Cited by 1,197
Mitchell, G. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90549.2008 · Cited by 764
Self-citationO’Rourke, M. F., & Nichols, W. W. (2005) · Hypertension · doi:10.1161/01.hyp.0000153793.84859.b8 · Cited by 543
Endothelial Dysfunction, Arterial Stiffness, and Heart Failure
Marti, C. N., Gheorghiade, M., Kalogeropoulos, A. P., Georgiopoulou, V. V., Quyyumi, A. A., & Butler, J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.082 · Cited by 488
Metadata
- Authors
- Mitchell, G. F., Tardif, J.-C., Arnold, J. M. O., Marchiori, G., O’Brien, T. X., Dunlap, M. E., & Pfeffer, M. A.
- Venue
- Hypertension
- Published
- 2001-12
- Volume
- 38
- Issue
- 6
- Pages
- 1433-1439
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2160845309
- Cited by
- 203
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsatile Hemodynamics in Congestive Heart Failure. https://app.cochat.ai/papers/10.1161/hy1201.098298
- The paper
- Mitchell, G. F., Tardif, J.-C., Arnold, J. M. O., Marchiori, G., O’Brien, T. X., Dunlap, M. E., & Pfeffer, M. A. (2001). Pulsatile Hemodynamics in Congestive Heart Failure. Hypertension. https://doi.org/10.1161/hy1201.098298
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.