CoChat

Cardioprotective Angiotensin-(1–7) Peptide Acts as a Natural-Biased Ligand at the Angiotensin II Type 1 Receptor

Galandrin, Ségolène, Denis, Colette, Boularan, Cédric, Marie, Jacky, M’Kadmi, Céline, Pilette, Claire, Dubroca, Caroline, Nicaise, Yvan, Seguelas, Marie-Hélène, N’Guyen, Du, Banères, Jean-Louis, Pathak, Atul, Sénard, Jean-Michel, Galés, Céline · 2016 · Hypertension
Cited by 108

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Hyperactivity of the renin–angiotensin–aldosterone system through the angiotensin II (Ang II)/Ang II type 1 receptor (AT1-R) axis constitutes a hallmark of hypertension. Recent findings indicate that only a subset of AT1-R signaling pathways is cardiodeleterious, and their selective inhibition by biased ligands promotes therapeutic benefit. To date, only synthetic biased ligands have been described, and whether natural renin–angiotensin–aldosterone system peptides exhibit functional selectivity at AT1-R remains unknown. In this study, we systematically determined efficacy and potency of Ang II, Ang III, Ang IV, and Ang-(1–7) in AT1-R–expressing HEK293T cells on the activation of cardiodeleterious G-proteins and cardioprotective β-arrestin2. Ang III and Ang IV fully activate similar G-proteins than Ang II, the prototypical AT1-R agonist, despite weaker potency of Ang IV. Interestingly, Ang-(1–7) that binds AT1-R fails to promote G-protein activation but behaves as a competitive antagonist for Ang II/Gi and Ang II/Gq pathways. Conversely, all renin–angiotensin–aldosterone system peptides act as agonists on the AT1-R/β-arrestin2 axis but display biased activities relative to Ang II as indicated by their differences in potency and AT1-R/β-arrestin2 intracellular routing. Importantly, we reveal Ang-(1–7) a known Mas receptor-specific ligand, as an AT1-R–biased agonist, selectively promoting β-arrestin activation while blocking the detrimental Ang II/AT1-R/Gq axis. This original pharmacological profile of Ang-(1–7) at AT1-R, similar to that of synthetic AT1-R–biased agonists, could, in part, contribute to its cardiovascular benefits. Accordingly, in vivo, Ang-(1–7) counteracts the phenylephrine-induced aorta contraction, which was blunted in AT1-R knockout mice. Collectively, these data suggest that Ang-(1–7) natural-biased agonism at AT1-R could fine-tune the physiology of the renin–angiotensin–aldosterone system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.116.08118

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Galandrin, S., Denis, C., Boularan, C., Marie, J., M’Kadmi, C., Pilette, C., Dubroca, C., Nicaise, Y., Seguelas, M.-H., N’Guyen, D., Banères, J.-L., Pathak, A., Sénard, J.-M., & Galés, C.
Venue
Hypertension
Published
2016-12
Volume
68
Issue
6
Pages
1365-1374
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2529251769
Cited by
108
References
3
FWCI
9.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.