Randomized Interventional Study on Prediction of Preeclampsia/Eclampsia in Women With Suspected Preeclampsia: INSPIRE

Open access
Cerdeira, Ana Sofia, O’Sullivan, Joe, Ohuma, Eric O., Harrington, Deborah, Szafranski, Pawel, Black, Rebecca, Mackillop, Lucy, Impey, Lawrence, Greenwood, Catherine, James, Tim, Smith, Ian, Papageorghiou, Aris T., Knight, Marian, Vatish, Manu · 2019 · Hypertension

Abstract

The ratio of maternal serum sFlt-1 (soluble fms-like tyrosine kinase 1) to PlGF (placental growth factor) has been used retrospectively to rule out the occurrence of preeclampsia, a pregnancy hypertensive disorder, within 7 days in women presenting with clinical suspicion of preeclampsia. A prospective, interventional, parallel-group, randomized clinical trial evaluated the use of sFlt-1/PlGF ratio in women presenting with suspected preeclampsia. Women were assigned to reveal (sFlt-1/PlGF result known to clinicians) or nonreveal (result unknown) arms. A ratio cutoff of 38 was used to define low (≤38) and elevated risk (>38) of developing the condition in the subsequent week. The primary end point was hospitalization within 24 hours of the test. Secondary end points were development of preeclampsia and other adverse maternal-fetal outcomes. We recruited 370 women (186 reveal versus 184 nonreveal). Preeclampsia occurred in 85 women (23%). The number of admissions was not significantly different between groups (n=48 nonreveal versus n=60 reveal; P =0.192). The reveal trial arm admitted 100% of the cases that developed preeclampsia within 7 days, whereas the nonreveal admitted 83% ( P =0.038). Use of the test yielded a sensitivity of 100% (95% CI, 85.8–100) and a negative predictive value of 100% (95% CI, 97.1–100) compared with a sensitivity of 83.3 (95% CI, 58.6–96.4) and negative predictive value of 97.8 (95% CI, 93.7–99.5) with clinical practice alone. Use of the sFlt-1/PlGF ratio significantly improved clinical precision without changing the admission rate. Clinical Trial Registration—: URL: http://www.isrctn.com . Unique identifier: ISRCTN87470468.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.119.12739

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Cerdeira, A. S., O’Sullivan, J., Ohuma, E. O., Harrington, D., Szafranski, P., Black, R., Mackillop, L., Impey, L., Greenwood, C., James, T., Smith, I., Papageorghiou, A. T., Knight, M., & Vatish, M.
Venue
Hypertension
Published
2019-10
Volume
74
Issue
4
Pages
983-990
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2968068787
Cited by
162
References
2
FWCI
13.77
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Interventional Study on Prediction of Preeclampsia/Eclampsia in Women With Suspected Preeclampsia: INSPIRE. https://app.cochat.ai/papers/10.1161/hypertensionaha.119.12739
The paper
Cerdeira, A. S., O’Sullivan, J., Ohuma, E. O., Harrington, D., Szafranski, P., Black, R., Mackillop, L., Impey, L., Greenwood, C., James, T., Smith, I., Papageorghiou, A. T., Knight, M., & Vatish, M. (2019). Randomized Interventional Study on Prediction of Preeclampsia/Eclampsia in Women With Suspected Preeclampsia: INSPIRE. Hypertension. https://doi.org/10.1161/hypertensionaha.119.12739

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.