A New Risk Scheme to Predict Ischemic Stroke and Other Thromboembolism in Atrial Fibrillation: The ATRIA Study Stroke Risk Score
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Background: More accurate and reliable stroke risk prediction tools are needed to optimize anticoagulation decision making in patients with atrial fibrillation ( AF ). We developed a new AF stroke prediction model using the original A nticoagulation and R isk F actors in A trial F ibrillation ( ATRIA ) AF cohort and externally validated the score in a separate, contemporary, community‐based inception AF cohort, ATRIA – C ardiovascular R esearch N etwork ( CVRN ) cohort. Methods and Results: The derivation ATRIA cohort consisted of 10 927 patients with nonvalvular AF contributing 32 609 person‐years off warfarin and 685 thromboembolic events ( TE s). The external validation ATRIA ‐ CVRN cohort included 25 306 AF patients contributing 26 263 person‐years off warfarin and 496 TE s. Cox models identified 8 variables, age, prior stroke, female sex, diabetes mellitus, heart failure, hypertension, proteinuria, and eGFR <45 mL/min per 1.73 m 2 or end‐stage renal disease, plus an age×prior stroke interaction term for the final model. Point scores were assigned proportional to model coefficients. The c‐index in the ATRIA cohort was 0.73 (95% CI , 0.71 to 0.75), increasing to 0.76 (95% CI , 0.74 to 0.79) when only severe events were considered. In the ATRIA ‐ CVRN , c‐indexes were 0.70 (95% CI , 0.67 to 0.72) and 0.75 (95% CI , 0.72 to 0.78) for all events and severe events, respectively. The C‐index was greater and net reclassification improvement positive comparing the ATRIA score with the CHADS 2 or CHA 2 DS 2 ‐VASc scores. Conclusions: The ATRIA stroke risk score performed better than existing risk scores, was validated successfully, and showed improvement in predicting severe events, which is of greatest concern. The ATRIA score should improve the antithrombotic decision for patients with AF and should provide a secure foundation for the addition of biomarkers in future prognostic models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harrell, F. E. (2001) · Springer Series in Statistics · doi:10.1007/978-1-4757-3462-1 · Cited by 9,195
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388 · cited 1×
“A trial fibrillation (AF) is a common arrhythmia that increases the risk for ischemic stroke by 4- to 5-fold.(1) Oral anticoagulant therapy is highly effective at reducing stroke risk in patients with AF but raises the risk of major bleeding.”
BackgroundJanuary, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Harrell (2015) · Springer Series in Statistics · doi:10.1007/978-3-319-19425-7 · Cited by 6,878
Interobserver agreement for the assessment of handicap in stroke patients
van Swieten, J. C., Koudstaal, P. J., Visser, M. C., Schouten, H. J., & van Gijn, J. (1988) · Stroke · doi:10.1161/01.str.19.5.604 · Cited by 6,512
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Andrade, J. G., Aguilar, M., Atzema, C., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 562
Piccini, J. P., Stevens, S. R., Chang, Y., Singer, D. E., Lokhnygina, Y., Go, A. S., Patel, M. R., Mahaffey, K. W., Halperin, J. L., Breithardt, G., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.107128 · Cited by 502
Self-citationGanesan, A. N., Chew, D. P., Hartshorne, T., Selvanayagam, J. B., Aylward, P. E., Sanders, P., & McGavigan, A. D. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw007 · Cited by 391
Stroke Prevention in Atrial Fibrillation: A Systematic Review
Lip, G. Y. H., & Lane, D. A. (2015) · JAMA · doi:10.1001/jama.2015.4369 · Cited by 322
Turakhia, M. P., Blankestijn, P. J., Carrero, J.-J., Clase, C. M., Deo, R., Herzog, C. A., Kasner, S. E., Passman, R. S., Pecoits-Filho, R., Reinecke, H., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy060 · Cited by 288
Go, A. S., Reynolds, K., Yang, J., Gupta, N., Lenane, J., Sung, S. H., Harrison, T. N., Liu, T. I., & Solomon, M. D. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1176 · Cited by 286
Self-citationLip, G. Y. H., Collet, J.-P., Haude, M., Byrne, R., Chung, E. H., Fauchier, L., Halvorsen, S., Lau, D., Lopez-Cabanillas, N., Lettino, M., et al. (2019) · EP Europace · doi:10.1093/europace/euy174 · Cited by 274
Chao, T.-F., Liu, C.-J., Wang, K.-L., Lin, Y.-J., Chang, S.-L., Lo, L.-W., Hu, Y.-F., Tuan, T.-C., Chen, T.-J., Lip, G. Y. H., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.11.046 · Cited by 258
Borre, E., Goode, A., Raitz, G., Shah, B., Lowenstern, A., Chatterjee, R., Sharan, L., Allen LaPointe, N., Yapa, R., Davis, J., et al. (2018) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1675400 · Cited by 229
Lip, G. Y. H., Coca, A., Kahan, T., Boriani, G., Manolis, A. S., Olsen, M. H., Oto, A., Potpara, T. S., Steffel, J., Marín, F., et al. (2017) · EP Europace · doi:10.1093/europace/eux091 · Cited by 219
Boriani, G., Savelieva, I., Dan, G.-A., Deharo, J. C., Ferro, C., Israel, C. W., Lane, D. A., La Manna, G., Morton, J., Mitjans, A. M., et al. (2015) · EP Europace · doi:10.1093/europace/euv202 · Cited by 182
Lampert, R., Chung, E. H., Ackerman, M. J., Arroyo, A. R., Darden, D., Deo, R., Dolan, J., Etheridge, S. P., Gray, B. R., Harmon, K. G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.05.018 · Cited by 167
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
How will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61
Reps, J. M., Williams, R. D., You, S. C., Falconer, T., Minty, E., Callahan, A., Ryan, P. B., Park, R. W., Lim, H.-S., & Rijnbeek, P. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-00991-3 · Cited by 40
“The existing models we replicated were ATRIA, CHADS2, CHA2DS2 −VASc, Framingham and Q-Stroke.”
MethodInfluentialGupta, N., Yang, J., Reynolds, K., Lenane, J., Garcia, E., Sung, S. H., Harrison, T. N., Solomon, M. D., & Go, A. S. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2021.11.027 · Cited by 14
Self-citationKumbhani, D. J., Armbruster, A. L., Cheng, R. K., Chrispin, J., Fischer, U., Holbrook, A. M., Joglar, J., & Sevestre, M.-A. (2026) · JACC · doi:10.1016/j.jacc.2026.05.033 · Cited by 2
Metadata
- Authors
- Singer, D. E., Chang, Y., Borowsky, L. H., Fang, M. C., Pomernacki, N. K., Udaltsova, N., Reynolds, K., & Go, A. S.
- Venue
- Journal of the American Heart Association
- Published
- 2013-05-20
- Volume
- 2
- Issue
- 3
- Pages
- e000250-e000250
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2154328340
- Cited by
- 405
- References
- 34
- FWCI
- 17.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.