CoChat

Multi‐Center, Community‐Based Cardiac Implantable Electronic Devices Registry: Population, Device Utilization, and Outcomes

Open access
Gupta, Nigel, Kiley, Mary Lou, Anthony, Faith, Young, Charlie, Brar, Somjot, Kwaku, Kevin · 2016 · Journal of the American Heart Association
Cited by 44

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The purpose of this study is to describe key elements, clinical outcomes, and potential uses of the Kaiser Permanente–Cardiac Device Registry. Methods and Results: This is a cohort study of implantable cardioverter defibrillators ( ICD ), pacemakers ( PM ), and cardiac resynchronization therapy ( CRT ) devices implanted between January 1, 2007 and December 31, 2013 by ≈400 physicians in 6 US geographical regions. Registry data variables, including patient characteristics, comorbidities, indication for procedures, complications, and revisions, were captured using the healthcare system's electronic medical record. Outcomes were identified using electronic screening algorithms and adjudicated via chart review. There were 11 924 ICD s, 33 519 PM s, 4472 CRT s, and 66 067 leads registered. A higher proportion of devices were implanted in males: 75.1% ( ICD ), 55.0% ( PM ), and 66.7% ( CRT ), with mean patient age 63.2 years ( ICD ), 75.2 ( PM ), and 67.2 ( CRT ). The 30‐day postoperative incidence of tamponade, hematoma, and pneumothorax were ≤0.3% ( ICD ), ≤0.6% ( PM ), and ≤0.4% ( CRT ). Device failures requiring revision occurred at a rate of 2.17% for ICD s, 0.85% for PM s, and 4.93% for CRT s, per 100 patient observation years. Superficial infection rates were <0.03% for all devices; deep infection rates were 0.6% ( ICD ), 0.5% ( PM ), and 1.0% ( CRT ). Results were used to monitor vendor‐specific variations and were systematically shared with individual regions to address potential variations in outcomes, utilization, and to assist with the management of device recalls. Conclusions: The Kaiser Permanente–Cardiac Device Registry is a robust tool to monitor postprocedural patient outcomes and postmarket surveillance of implants and potentially change practice patterns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.115.002798

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Gupta, N., Kiley, M. L., Anthony, F., Young, C., Brar, S., & Kwaku, K.
Venue
Journal of the American Heart Association
Published
2016-03-09
Volume
5
Issue
3
Pages
e002798-e002798
ISSN
2047-9980 (ISSN-L)
OpenAlex
W2294748112
Cited by
44
References
2
FWCI
5.98
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.