Accuracy of ICD‐9‐CM Codes by Hospital Characteristics and Stroke Severity: Paul Coverdell National Acute Stroke Program
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Epidemiological and health services research often use International Classification of Diseases, Ninth Revision, Clinical Modification ( ICD ‐9‐ CM ) codes to identify patients with clinical conditions in administrative databases. We determined whether there are systematic variations between stroke patient clinical diagnoses and ICD ‐9‐ CM codes, stratified by hospital characteristics and stroke severity. Methods and Results: We used the records of patients discharged from hospitals participating in the Paul Coverdell National Acute Stroke Program in 2013. Within this stroke‐enriched cohort, we compared agreement between the attending physician's clinical diagnosis and principal ICD ‐9‐ CM code and determined whether disagreements varied by hospital characteristics (presence of a stroke unit, stroke team, number of hospital beds, and hospital location). For patients with a documented National Institutes of Health Stroke Scale score at admission, we assessed whether diagnostic agreement varied by stroke severity. Agreement was generally high (>89%); differences between the physician diagnosis and ICD ‐9‐ CM codes were primarily attributed to discordance between ischemic stroke and transient ischemic attack ( TIA) , and subarachnoid and intracerebral hemorrhage. Agreement was higher for patients in metropolitan hospitals with stroke units, stroke teams, and >200 beds (all P <0.001). Agreement was lowest (60.3%) for rural hospitals with ≤200 beds and without stroke units or teams. Agreement was also lower for milder (94.9%) versus more‐severe (96.4%) ischemic strokes ( P <0.001). Conclusions: We identified disagreements in stroke/ TIA coding by hospital characteristics and stroke severity, particularly for milder ischemic strokes. Such systematic variations in ICD ‐9‐ CM coding practices can affect stroke case identification in epidemiological studies and may have implications for hospital‐level quality metrics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Self-citation
Cited by
Bosco, E., Hsueh, L., McConeghy, K. W., Gravenstein, S., & Saade, E. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01440-5 · Cited by 568
The microRNA regulatory landscape of MSC-derived exosomes: a systems view
Ferguson, S. W., Wang, J., Lee, C. J., Liu, M., Neelamegham, S., Canty, J. M., & Nguyen, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-19581-x · Cited by 360
The role of wearables in heart failure
Singhal, A., & Cowie, M. R. (2020) · Current Heart Failure Reports · doi:10.1007/s11897-020-00467-x · Cited by 85
Mobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
Hospital-wide natural language processing summarising the health data of 1 million patients
Bean, D. M., Kraljevic, Z., Shek, A., Teo, J., & Dobson, R. J. B. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000218 · Cited by 22
“Structured codes are also not error-free [25,26].”
Metadata
- Authors
- Chang, T. E., Lichtman, J. H., Goldstein, L. B., & George, M. G.
- Venue
- Journal of the American Heart Association
- Published
- 2016-06-13
- Volume
- 5
- Issue
- 6
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2415613518
- Cited by
- 59
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of ICD‐9‐CM Codes by Hospital Characteristics and Stroke Severity: Paul Coverdell National Acute Stroke Program. https://app.cochat.ai/papers/10.1161/jaha.115.003056
- The paper
- Chang, T. E., Lichtman, J. H., Goldstein, L. B., & George, M. G. (2016). Accuracy of ICD‐9‐CM Codes by Hospital Characteristics and Stroke Severity: Paul Coverdell National Acute Stroke Program. Journal of the American Heart Association. https://doi.org/10.1161/jaha.115.003056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.