Cited by 85Non-Invasive Vital Sign MonitoringHeart Failure Treatment and ManagementMobile Health and mHealth Applications

The role of wearables in heart failure

Open access
Singhal, Arvind, Cowie, Martin R.·2020·Current Heart Failure Reports

Abstract

PURPOSE OF REVIEW: This review discusses how wearable devices-sensors externally applied to the body to measure a physiological signal-can be used in heart failure (HF) care. RECENT FINDINGS: Most wearables are marketed to consumers and can measure movement, heart rate, and blood pressure; detect and monitor arrhythmia; and support exercise training and rehabilitation. Wearable devices targeted at healthcare professionals include ECG patch recorders and vests, patches, and textiles with in-built sensors for improved prognostication and the early detection of acute decompensation. Integrating data from wearables into clinical decision-making has been slow due to clinical inertia and concerns regarding data security and validity, lack of evidence of meaningful impact, interoperability, regulatory and reimbursement issues, and legal liability. Although few studies have assessed how best to integrate wearable technologies into clinical practice, their use is rapidly expanding and may support improved decision-making by patients and healthcare professionals along the whole patient pathway.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11897-020-00467-x

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [41]NICE (National Institute for Health and Care Excellence). Putting NICE guidance into practice: Chronic heart failure in adults: diagnosis and management (NG106). Published September 2018. https://www.nice.org.uk/guidance/ng106/resources/resourceimpact-report-pdf-6537494413. Accessed February 26, 2020. 30645061

Cited by

Sorted by citations

Authors
Singhal, A., & Cowie, M. R.
Affiliations
Royal Brompton Hospital (GB)
Venue
Current Heart Failure Reports
Published
2020-06-03
Volume
17
Issue
4
Pages
125-132
ISSN
  • 1546-9530 (ISSN-L)
  • 1546-9549
OpenAlex
W3030407885
Cited by
85
References
57
Citations by year
2026: 4 · 2025: 13 · 2024: 17 · 2023: 16 · 2022: 21 · 2021: 12 · 2020: 2
FWCI
1.07
Type
journal article
Language
en
Open access
Locations
  • Current Heart Failure Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Spiral (Imperial College London) (submittedVersion, cc-by)
Funders
Imperial College London
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
wearable devices, heart failure, remote monitoring, arrhythmia detection, ECG patch, acute decompensation, clinical decision-making, interoperability, data security, exercise rehabilitation
MeSH terms
Wearable Electronic Devices, Equipment Design, Heart Failure, Heart Rate, Humans, Monitoring, Physiologic, Exercise

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›